Request a Quote

To speak with a Wake Industrial representative now, call 1-877-918-7411. If you’d rather send an email with an excel sheet, send an email to sales@wakeindustrial.com with a subject titled: “Surplus for Sale”. If you would prefer to use the Wake Industrial website, please click here to navigate to Wake Industrial contact page.
At Wake Industrial, surplus Indramat power supplies are more than outdated cabinet components sitting unused on a shelf. They are still valuable assets that support legacy Bosch Rexroth Indramat drive systems in facilities where reliable replacement hardware matters. If you are upgrading your automation platform, decommissioning older equipment, or clearing excess inventory, selling your surplus Indramat power supplies can help you recover value from hardware that no longer fits your operation. From regenerative and non-regenerative supply modules to DC bus power units used in established motion-control systems, these components still serve a real purpose in the aftermarket. Instead of letting unused Indramat power supplies take up space, send Wake Industrial your part numbers and unit details so we can review your inventory and provide a competitive surplus offer.
How It Works

The process starts with identifying what you have and sending Wake Industrial the exact part numbers you want reviewed. Once the part numbers and condition are clear, the equipment can be evaluated against current demand for that specific configuration. If the offer works for you, the sale can move forward without the usual guesswork that happens when older automation parts are described too generally. That is especially important with Indramat drives and controller sections because similar-looking units may differ by master communication type, encoder support, control section design, cooling arrangement, or DC bus class. The more precise the identification, the easier it is to move surplus efficiently.
HVR Power Supply Units
HVR power supply units are engineered to provide a constant regulated DC bus voltage that remains unaffected by mains fluctuation. This makes the family important in drive systems that depend on stable DC bus behavior for dynamic performance. In surplus, HVR units are usually evaluated by their continuous and peak power ratings, their mains-voltage range, and their regenerated-energy handling. These are not generic cabinet power supplies; they are regulated drive-system modules that support legacy servo and spindle architectures.
| Part Number | Continuous Power | Mains Voltage |
| HVR02.2-W010N | 10 kW | 3 x 380 to 480 V ±10% |
| HVR03.2-W045N/S203 | 45 kW | 380 to 480 V |
| HVR03.2-W045N | 45 kW | 3 x AC 380 to 480 V |
HVE Power Supply Units
HVE power supply units are second-generation drive-system supply modules that create the DC bus used by connected drive controllers. These units operate with an unregulated DC bus and handle regenerated energy through an integrated bleeder concept, which makes them distinct from regulated regenerative supply families. In surplus, HVE modules matter because they sit at the power backbone of the drive system and determine how multiple connected controllers are supported. Rated power, cooling, and bleeder characteristics are all useful in separating one HVE configuration from another.
| Part Number | Rated Power | Cooling | Bus / Energy Handling |
| HVE02.2-W018N | 18 kW | Internal air cooling | Peak bleeder power 100 kW, continuous bleeder power 1 kW |
| HVE03.2-W030N | 30 kW | Internal air cooling | Stabilized DC bus, returns excess energy to line or internal bleeder |
| HVE04.2-W075N | 75 kW | Internal air cooling | Continuous DC bus power 90 kW, peak 270 kW for 0.3 s |
HMV IndraDrive Supply Units
HMV IndraDrive supply units distribute bus power to multiple connected drive controllers and support both feed and regenerative configurations depending on the model. They are central to shared DC-bus IndraDrive architectures, which means their value in surplus often depends on rated output, DC bus voltage, and supply type rather than appearance alone. These modules are especially important in cabinets where the supply section is being separated from still-usable axis hardware. A correct HMV type code makes it easier to distinguish a feeder unit from a regenerative supply.
| Part Number | Rated Output | DC Bus Voltage | Cooling |
| HMV01.1E-W0075 | 75 kW | 700 V | Internal air blower |
| HMV01.1R-W0065 | 65 kW | DC 700 V | Internal air blower |
| HMV01.1R-W0120 | 120 | 700 VDC | Internal air blower |