4.95 based on 202 reviews

🙶 Product was as advertised, got the machine back up and running at a fraction of OEM price. Delivered on ti... 🙷

AKD-B00306-NBAN-0000 Kollmorgen

In-Stock, Ships 1-2 Days

Preparing your secure checkout page...

The AKD-B00306-NBAN-0000 is a servo drive from the AKD Servo Drives series by Kollmorgen and has a weight of 1.1 kilograms. It features analog fieldbus connectivity, a nominal current of 3 Arms, and a peak output current of 9 Arms for 5 seconds. This base version drive is rated for an input power of 1.2 KVA and supports supply voltages of 120 or 240 Vac for single or three-phase operation.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The AKD-B00306-NBAN-0000 servo drive is manufactured by Kollmorgen as part of the AKD Servo Drives series. It functions as the power stage that links a motion controller to a synchronous or induction motor, converting line power into regulated output current. Within an automation cell, the drive manages position, speed, and torque loops so actuators follow commanded trajectories under varying loads and temperatures. This closed-loop behavior helps the connected axis remain stable during starts, stops, and speed changes.

The drive can deliver a continuous phase current of 3 Arms, which is the sustained motor current available during normal operation. For short acceleration bursts, it supplies up to 9 Arms for five seconds, giving extra headroom for rapid indexing or temporary peak loads. The power section is rated at 1.2 kVA, and it accepts 120/240 Vac on single-phase or three-phase input. With a mass of only 1.1 kg, the unit adds little weight to a control cabinet and fits easily on narrow DIN rails or backplates. The broad input option supports use in both smaller standalone equipment and larger plant installations.

The standard USA version aligns the product with North American electrical conventions and motor insulation practices. It uses the base drive version, so optional expansion features are not included in the standard configuration. Command signals are handled through an analog interface, making the drive compatible with ±10 V velocity commands or 4–20 mA process signals from legacy PLC hardware. This allows direct interfacing with older control systems that still rely on analog setpoints. The unit is supplied with no hardware extension for revision 8 and later, leaving the internal expansion bay unoccupied. The open expansion bay keeps the configuration focused on core motion control without added option boards.

Customization Variant
Standard USA
Drive Version
Base
Fieldbus Connectivity
Analog
Hardware Extension
None (rev 8+)
Nominal Current
3 Arms
Peak Output Current (5s)
9 Arms
Product Family
AKD Servo Drive
Rated Input Power S1
1.2 KVA
Rated Supply Voltage
120 / 240 Vac 1~/3~
Weight (Standard Width)
1.1 kg
Fault Code Drive message (AKD display) Typical reason(s) Recommended corrective action
F106 NV memory data invalid Parameter area of the EEPROM is corrupted (often after interrupted firmware download)

• Reset parameters with WorkBench → Parameter Load → Factory Defaults.

• Power-cycle the drive. If fault re-occurs, reload firmware.

F121 Homing error Homing sequence did not complete (bad sensor, wrong homing mode, limits active)

• Verify home switch wiring & logic.

• Check HOME.MODE / HOME.DIR / HOME.FEEDRATE settings.

• Re-run homing.

F207 Control-board EEPROM corrupted – parameter stamp Stamp section of control-board EEPROM unreadable

• Power-cycle.

• Reload parameter set.

• If fault persists, replace the drive (EEPROM failure). 

F208 Control-board EEPROM corrupted – parameter data Parameter data area unreadable Same steps as F207 (reload / replace drive if necessary). 
F245 External fault User-configured digital input (DINx.MODE = 10) is active

• Check wiring to the configured DIN.

• Clear the input signal to reset the fault.

F305 Brake open circuit Motor brake coil not detected (broken wire, connector loose)

• Inspect motor brake wiring at X5/X6.

• Verify brake coil resistance.

F306 Brake short circuit Motor brake coil shorted or driver transistor failed

• Measure brake coil resistance; compare with spec.

• Replace brake or drive if resistance is < 10 Ω.

F308 Voltage exceeds motor rating DC-bus voltage higher than allowed for the connected motor

• Verify motor name-plate voltage.

• Reduce bus voltage or fit correct motor. 

F401 Failed to set feedback type Feedback wiring/config doesn’t match selected protocol (EnDat, SFD, etc.)

• Check feedback cable & shield.

• Ensure FBTYPE matches encoder.

Reset after correcting wiring. 

F404 Hall error Illegal Hall state (000 or 111) – broken Hall sensor line

• Inspect Hall signals at X10.

• Check motor feedback connector pins A,B,C.

Model  Cont. Current(A rms) Peak Current(A rms, 5 s) Cont. OutputPower Mains Class Typical mains wiring
AKD-B00306-NBAN-0000
 
3 9 1,100 W 120 / 240 V 1- or 3-phase (2P/3P)
AKD-B00606-NBAN-0000 6 18 2,000 W 120 / 240 V 1- or 3-phase
AKD-B01206-NBAN-0000 12 30 4,000 W 120 / 240 V 1- or 3-phase 
AKD-B02406-NBAN-0000 24 48 8,000 W 120 / 240 V 3-phase recommended 
AKD-B02407-NBAN-0000 24 48 16,000 W 240 / 480 V 3-phase only 
AKD-B04807-NBAN-0000 48 96 32 000 240 / 480 V 3-phase only 
Code What it means 
F201 – Internal RAM failed Corrupt memory detected on the control board.
F202 – External RAM failed External RAM self-test did not pass at power-up.
F208 – Control-board EEPROM corrupted (parameter data) Parameter block checksum error.
F209 – Power-board EEPROM read failed Drive can’t read bus-power board data.
F210 – Power-board EEPROM corrupted (serial-number stamp) SN stamp checksum error on power board.
F212 – Power-board EEPROM corrupted (serial-number data) Serial-number data block unreadable.
F214 – Power-board EEPROM corrupted (parameter data) Parameter block on power board is bad.
F219 – Control-board EEPROM write failed Drive tried to store parameters but write did not verify.
F230 – Power-board EEPROM write failed Parameter write to power board couldn’t be completed.
F232 – Power-board EEPROM invalid data Drive detects nonsensical data after a save/read cycle.

Frequently Asked Questions about AKD-B00306-NBAN-0000:

Q: What is the rated input power of the AKD-B00306-NBAN-0000 servo drive?

A: The rated input power for the AKD-B00306-NBAN-0000 is 1.2 KVA during continuous operation.

Q: What is the peak output current of the AKD-B00306-NBAN-0000 drive?

A: This servo drive supports a peak output current of 9 Arms for up to 5 seconds.

Q: What type of fieldbus connectivity does the AKD-B00306-NBAN-0000 use?

A: The AKD-B00306-NBAN-0000 is designed with analog fieldbus connectivity for integration with compatible control systems.

Q: What is the rated supply voltage for the AKD-B00306-NBAN-0000?

A: The rated supply voltage range for this model is 120 or 240 Vac, suitable for single-phase or three-phase input.

Q: Does the AKD-B00306-NBAN-0000 have any hardware extensions included?

A: No hardware extensions are included on the AKD-B00306-NBAN-0000, as it uses hardware revision 8 or higher without additional modules.


Internal Product Review

  • ‘‘The AKD-B00306-NBAN-0000 is a Kollmorgen AKD servo drive with analog fieldbus connectivity. Rated for 3 Arms nominal current and 9 Arms peak output current for 5 seconds, the drive shows strong control headroom for compact motion axes. Support for 120 / 240 Vac single- or three-phase input makes the drive a dependable choice for flexible machine integration.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo