The AKD-P00606-NBAN-0000 is manufactured by Kollmorgen as part of the AKD Servo Drive Series. These drives are fast, and flexible drives with features such as a drive continous output power of 2000 Watts and a rated supply voltage of 120/240 V. As well as, Rated output current of 6 A and a peak output current of 18 A. AKD drives offer the greatest output in a compact body.

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Motion control on the industrial floor was significantly improved with the introduction of Kollmogen’s AKD range of drives.  Kollmorgen AKD servo drives are highly flexible enabling them to be interfaced with a wide array of industrial applications. Apart from flexibility, AKD drives offer plug-and-play functionalities reducing the time it takes to set-up a servo system. AKD drives have a compact size allowing them to occupy less space without compromising their industry-leading performance. To ease programming, monitoring, and troubleshooting, these drives have a graphical user interface and advanced autotuning functionalities. To seamlessly fit into the industrial power supply network, AKD series drives support an operating voltage of between 120 Volts AC and 480 Volts AC.

The Kollmorgen AKD-P00606-NBAN-0000 is a position indexer servo drive. It has a plug-and-play compatibility with Kollmorgen motors and supports the Kollmorgen WorkBench software for easy programming. The AKD-P00606-NBAN-0000 belongs to the AKD-P subseries in the wider AKD series. The drive is designed to be operated as a component of an electrical industrial system or machine and is meant to operate optimally when interfaced with synchronous servo motors employing closed-loop control of torque, position, and or speed. AKD drives are designed to be operated in a closed control cabinet with the temperature inside the cabinet not exceeding 40 degrees Celsius.

The AKD-P00606-NBAN-0000 can be powered by either a single phase or a three phase power source supplying either 120 Volts AC or 240 Volts AC. The drive features an analog connectivity option and a current rating of 6 ARMS. For the drive to operate as intended, it should be mounted in an environment with an altitude not exceeding 1000 meters above sea level, a level 2 pollution, and with vibrations not exceeding IEC’s class 3M1.

Connectivity Option
Analog
Control Logic, Supply Voltage
24 V
Current Rating
6 Arms
Customization
standard USA
Extension Options
None(rev 8+)
Protection category
IP20
Rated input power for S1 operation
2.38kVA
Rated supply input frequency
50Hz to 400Hz
Voltage rating
120/240Vac
Weight
1.7kg
  • AKDP00606-NBAN-0000
  • AKD-POO6O6-NBAN-OOOO
Fault Code Fault / Alarm Name Likely Cause(s) Quick Fix
F501 Bus Over-Voltage Excess regenerative energy, decel ramp too steep, or high mains voltage Lengthen decel time, add/size brake resistor, verify mains voltage.
F502 Bus Under-Voltage Mains sag, input phase loss, weak supply transformer Check incoming power on L1/L2/L3, correct wiring, stabilise supply.
F503 Bus Capacitor Overload Running drive on single-phase supply or large single-phase load Use correct 3-phase input or share DC bus between drives.
F301 Motor Overheated Continuous high RMS current, blocked airflow, high ambient Reduce load/servo gains, improve cooling, allow motor to cool before reset.
F302 Overspeed Velocity command or disturbance pushes motor past VL.THRESH Raise VL.THRESH if application allows, or limit speed command.
F401 Feedback-Type Error Drive expects different feedback device, or wiring fault Select correct feedback type in WorkBench, re-seat/inspect X10 connector.
F402 Analog Signal Amplitude Fault Resolver / Sin-Cos amplitude too low or too high Verify encoder/resolver cabling and shielding; check sensor supply.
F305 Brake Open-Circuit Motor brake coil open or cable disconnected Inspect brake harness for continuity, repair or replace wiring.
F521 Regen Over-Power Dynamic-brake resistor too small for load energy Fit larger resistor or implement DC-bus sharing across drives.
F121 Homing Error Homing switch not seen / sequence not completed Check homing sensor wiring & logic, verify HOMING.MODE parameters.
Model Cont. Current (A) Peak Current (A) Power (kW) Input VAC Network / Command Interface
AKD-P00606-NBAN-0000 6 18 2 120 / 240 Analog (+ TCP/IP service port)
AKD-P00306-NBAN-0000 3 9 1.1 120 / 240 Analog
AKD-P00307-NBAN-0000 3 240 / 480 Analog
AKD-P00606-NBEC-0000 6 18 2 120 / 240 EtherCAT
AKD-P01206-NBAN-0000 12 30 4 120 / 240 Analog
AKD-P02406-NBAN-0000 24 120 / 240 Analog
Fault Code What It Means
F101  Firmware incompatible
F301 Motor overheated
F302  Over-speed
F305 Brake open circuit 
F401 Feedback-type error
F402  Analog-signal amplitude fault
F501 Bus over-voltage
F502  Bus under-voltage
F503 Bus-capacitor overload
F521 Regen over-power

Frequently Asked Questions about AKD-P00606-NBAN-0000:

Q: Can the AKD-P00606-NBAN-0000 stored for more than one year?

A: The storage of the AKD-P00606-NBAN-0000 for a period that exceed one year is allowed. However if this is done, the capacitors in the controller must be re-formed before setting up and operating the drive. The drive controller should also be stored in the manufacturer's original recyclable packaging.

Q: Are operators allowed to open the housing of the AKD-P00606-NBAN-0000 for maintenance?

A: The AKD-P00606-NBAN-0000 does not require maintenance operation, and the opening of the housing voids the warranty covering the device. Also during cleaning, do not imerse or spray the device.

Q: How can the AKD-P00606-NBAN-0000 be identified upon delivery?

A: A nameplate is attached to the AKD-P00606-NBAN-0000 upon delivery. The name plate contain important identification information such as technical data, name plate, model number and serial number. Customers should verify the information on the type plate upon delivery.

Q: How quickly will the AKD-P00606-NBAN-0000 be delivered to me after I palce my order?

A: Confirmed orders are processed and shipped within 48 hours. Our deliveries are handled by DHL, UPS and Fedex. The time the controller reach you depends on your location.

Q: Is the AKD-P00606-NBAN-0000 environmentally friendly?

A: Yes. In the case of proper operation, the AKD-P00606-NBAN-0000 does not have any negative effect on the environment. The controller can also be returned to Kollmergen for recycling.