The PPC-R01.2N-N-B2-FW is a NC controller in the PPC series manufactured by Bosch Rexroth Indramat. This unit can be mounted on TS DIN rails inside the racks. The leakage current of the product exceeds 3.5 mA in normal operation. It has the Sercos interface that permits communication with up to 40 drives.

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

PPC-R01.2N-N-B2-FW is a PPC series NC control from Bosch Rexroth. The control can be used with Bosch VisualMotion GPP 9 firmware. It can plug directly into a RECO02 rack. The RECO02 rack can accommodate the NC control and RECO02 I/O modules. Communication between the NC control and I/O modules proceeds along the rack back plane. The PPC-R01.2N-N-B2-FW has one expansion slot. One fieldbus slave interface - Profibus, Interbus, DeviceNEt, ControlNet or Ethernet - can be used in the NC control. Features available on the NC control include a 4-digit alphanumeric display, PCMCIA flash card slot, SERCOS interface, and two serial interfaces. The SERCOS interface allows communication with up to 40 drives. The serial interface ports support baud rates ranging from 9600 to 115200 baud. The baud rate is set via software.

The permissible power cable size for the NC control is 1.5 mm2. The unit can be mounted on TS DIN rails inside the racks. Protection rating of the unit is IP20 and it cannot be used outdoors unless protected inside a suitable cabinet. The permitted humidity for operation is 5 to 78%. The permitted humidity range for transport is 5 to 95%. The atmospheric pressure range for operation is 860 to 1080 hPA. The atmospheric pressure range for transport is 660 to 1080 hPA. Bosch recommends 0 to 45 degrees Celsius temperature for rated output. The specified temperature range for transport and storage is -25 to 70 degrees Celsius. Weight of the unit is 1 kilogram. The unit requires 24 Volts DC nominal input. The permissible voltage range is 19 to 30 Volts DC. The peak current consumption of the NC control is 0.7 Amps.

Expansion slot
1
General purpose interface
RS-232
Manufacturer
Bosch Rexroth
Mounting orientation
Vertical
Mounting style
With brackets
Operating temperature
0 to 45 degrees Celsius
Product type
NC control
Programming interface
RS-232
Protection rating
IP20
Weight
1 kilogram
  • PPCR01.2N-N-B2-FW
  • PPCR01.2NNB2FW
  • PPC R01.2N N B2 FW
Fault code on display What it means First thing to check / do
F HW (19) PPC hardware-self-test failed Cycle power; if F HW (19) re-appears, replace the PPC module. 
F01 (01) SERCOS ring break Inspect fiber-optic cables & connectors, close the ring, reset PPC. 
F02 (02) No drives detected on SERCOS Check drive power, ID plugs, and addresses; re-initialise phase 1. 
F03 (03) Error when switching to phase 3 A drive did not acknowledge; view drive diag, fix, then re-enter phase 3. 
F04 (04) Can’t switch to operating mode Parameter mismatch; verify C-0-0086, number of drives, restart. 
F06 (06) Fiber-optic ring not closed Swap IN/OUT plugs or replace damaged fiber to complete loop. 
F07 (07) Drive addresses wrong Set unique SERCOS IDs (ID plug or keypad) - addresses 1…40 only. 
F08 (08) Max. number of drives exceeded Reduce attached drives or upgrade to PPC-R02 (two-slot) controller. 
F09 (09) Fatal internal error – PPC reset req. Save log with SynTop; power-cycle; replace controller if recurrent. 
F TN (25) PPC in test-mode “zero bit stream” Clear test mode bit C-0-0038, initialise, then restart. 
Controller Model Slots in RECO rack Field-bus & option code Typical use
PPC-R01.2N-N-B2-FW 1 B2 = InterBus-S master Motion/logic w. InterBus I/O
PPC-R01.2N-N-P2-FW  1 P2 = PROFIBUS-DP master Same CPU, Profibus instead of InterBus
PPC-R01.2N-N-T2-FW 1 T2 = SIS serial + analogue Point-to-point (SIS) link to older drives
PPC-R01.2N-N-L2-FW  1 L2 = SERCOS + RS-232 Pure SERCOS ring; fastest 40-axis control
PPC-R02.2N-N-B2-NN-FW 2 B2 InterBus-S High-load two-slot CPU, double SRAM
PPC-R01.2N-N-V2-FW 1 V2 = BT-Bus (operator panels) Adds video & BT-Bus for SynTop HMI
Code (display) What it means
F HW (19) PPC hardware-self-test failed
F01 (01) SERCOS interface – ring break (fiber ring open)
F02 (02) SERCOS interface – no drives connected
F03 (03) Error when switching to phase 3 (drive reported diagnostic)
F04 (04) Error when switching into operating mode
F06 (06) Fiber-optic ring not closed (Tx/Rx crossed or cable break)
F07 (07) Drive addresses incorrect (duplicate or zero)
F08 (08) Maximum number of drives in ring exceeded
F TN (25) PPC in test-mode “zero bit stream” (commissioning jumper left)
F09 (09) Fatal internal error – controller watchdog reset required

Frequently Asked Questions about PPC-R01.2N-N-B2-FW:

Q: What is the storage temperature?

A: The storage temperature is -25 to 70 degrees Celsius.

Q: What is the recommended power cable size?

A: The recommended power cable cross section is 1.5 mm2.

Q: What is the operating atmospheric pressure?

A: The operating atmospheric pressure is 860 to 1080 hPa.

Q: What is the acceptable humidity range?

A: The acceptable humidity range is 5 to 78%.

Q: What are the unit dimensions?

A: Dimensions of the unit are 192 x 41.5 x 128 millimeters.


Internal Product Review