PPC-R01.2N-N-B2-FW
MPN: R911289825
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
-
In-Stock, Ships 3-5 Days
The PPC-R01.2N-N-B2-FW is a NC controller in the PPC series manufactured by Bosch Rexroth Indramat. This unit can be mounted on TS DIN rails inside the racks. The leakage current of the product exceeds 3.5 mA in normal operation. It has the Sercos interface that permits communication with up to 40 drives.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
PPC-R01.2N-N-B2-FW is a PPC series NC control from Bosch Rexroth. The control can be used with Bosch VisualMotion GPP 9 firmware. It can plug directly into a RECO02 rack. The RECO02 rack can accommodate the NC control and RECO02 I/O modules. Communication between the NC control and I/O modules proceeds along the rack back plane. The PPC-R01.2N-N-B2-FW has one expansion slot. One fieldbus slave interface - Profibus, Interbus, DeviceNEt, ControlNet or Ethernet - can be used in the NC control. Features available on the NC control include a 4-digit alphanumeric display, PCMCIA flash card slot, SERCOS interface, and two serial interfaces. The SERCOS interface allows communication with up to 40 drives. The serial interface ports support baud rates ranging from 9600 to 115200 baud. The baud rate is set via software.
The permissible power cable size for the NC control is 1.5 mm2. The unit can be mounted on TS DIN rails inside the racks. Protection rating of the unit is IP20 and it cannot be used outdoors unless protected inside a suitable cabinet. The permitted humidity for operation is 5 to 78%. The permitted humidity range for transport is 5 to 95%. The atmospheric pressure range for operation is 860 to 1080 hPA. The atmospheric pressure range for transport is 660 to 1080 hPA. Bosch recommends 0 to 45 degrees Celsius temperature for rated output. The specified temperature range for transport and storage is -25 to 70 degrees Celsius. Weight of the unit is 1 kilogram. The unit requires 24 Volts DC nominal input. The permissible voltage range is 19 to 30 Volts DC. The peak current consumption of the NC control is 0.7 Amps.
Frequently Asked Questions about PPC-R01.2N-N-B2-FW:
Q: What is the storage temperature?
A: The storage temperature is -25 to 70 degrees Celsius.
Q: What is the recommended power cable size?
A: The recommended power cable cross section is 1.5 mm2.
Q: What is the operating atmospheric pressure?
A: The operating atmospheric pressure is 860 to 1080 hPa.
Q: What is the acceptable humidity range?
A: The acceptable humidity range is 5 to 78%.
Q: What are the unit dimensions?
A: Dimensions of the unit are 192 x 41.5 x 128 millimeters.