The Bosch Rexroth HMD01.1N-W0020-A-07-NNNN is a double-axis inverter designed for precise motor control. It supports a peak current of 20A and features internal air-cooling for reliable operation in automation systems.

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The Bosch Rexroth Indramat HMD01.1N-W0020-A-07-NNNN is a high-performance double-axis inverter designed to control two independent motors in various automated systems. Rexroth is a top company that makes drive and control technologies that make the inverter accurate and dependable. The HMD01.1N-W0020-A-07-NNNN is part of the IndraDrive system that integrates seamlessly with industrial automation solutions to offer efficient and scalable motor control.

The HMD01.1N-W0020-A-07-NNNN by Indramat supports a peak current of 20A and operates at a DC-bus nominal voltage of 700VDC to make it suitable for demanding applications. The double-axis inverter uses an internal air-cooling system via an integrated blower to maintain optimal performance. Designed for cabinet mounting, the inverter comes with an IP20 protection rating that restricts the amount of dust that can enter the device. Overvoltage limiters are also incorporated into the double-axis inverter. These limiters are activated when the voltage is greater than 33 volts that ensures that the inverter operates safely. The unit is flexible, with the capability to connect to external 24V power supplies through terminal blocks to support various configurations. The inverter works with IndraDrive M power supplies and can be monitored using IndraWorks software to make it adaptable for expanding systems.

The HMD01.1N-W0020-A-07-NNNN double-axis inverter operates reliably in conditions with an elevation of up to 1000 meters and temperatures ranging from 0 to 40 degrees C. The double-axis inverter is compatible with multiple power supply units, and its ability to monitor via software makes it an ideal component for scalable motor control in industrial automation. The inverter ensures consistent performance and easy integration into larger systems. With a one-year replacement warranty and global shipping, this product is built to meet the needs of many applications.

Compatibility
IndraDrive M and C systems
Cooling System
Internal air cooling (blower)
DC-bus Nominal Voltage
700VDC
External Power Supply
24V (optional connection)
Humidity Tolerance
Maximum 95% relative humidity
Maximum Operational Altitude
1000 meters
Mounting Type
Cabinet mounting
Number of Motors Controlled
Two
Operating Temperature Range
0 to 40 degrees C
Overvoltage Limiters
Activated above 33 volts
Peak Current
20A
Protection Rating
IP20
  • HMD011NW0020A07NNNN
  • HMD01 1N W0020 A 07 NNNN
  • hmd01.1n-w0020-a-07-nnnn
Fault / Error Code What it Means Typical Corrective Action
F8022 Encoder 1 signal(s) implausible (amplitude / phase error)  Check encoder plug, cable shield & routing; replace encoder if noise or damage persists, then reset drive.
F8023 Mechanical link between encoder and motor defective  Inspect shaft-coupling, keyway, or hollow-shaft clamp; tighten or replace, perform homing, clear fault.
F8025 DC-bus over-voltage in power section  Lengthen decel ramps, add or up-size brake resistor, verify mains over-voltage filter, then reset.
F8028 Over-current in power section  Check motor/drive sizing, look for shorted motor leads, retune current loop; clear fault and test at low load.
F8064 Interruption of one or more motor phases  Measure phase resistance & continuity, reseat power plug, inspect contact pins; replace cable if open.
F8070 +24 V control-supply error  Verify external PSU ≥ 24 V ±10 %, tighten terminals, use separate supply for logic, then reset diagnostics.
F8091 Power section reported as defective  Inspect heatsink & bus bars for arcing, cycle power after cooldown; persistent fault → replace drive module.
F8100 Error during parameter-handling initialization  Reload parameter file from backup or IndraWorks, re-initialize controller, then power-cycle.
F8120 Control-section / firmware combination invalid  Flash correct firmware version for installed CS, or fit matching CS module; reboot, re-license options.
F8135 Velocity threshold exceeded (trend monitoring)  Check motion profile for overspeed, verify gear ratio parameters, adjust limit P-0-0034, then clear fault.
Drive Controller Axes Continuous / Max Current (A) DC-Bus Range (V DC) Interface Type Width (mm)
HMD01.1N-W0020-A-07-NNNN  Double 20-Oct 254 – 750 Modular (Multi-Ethernet / SERCOS via CS) 50
HMD01.1N-W0012-A-07-NNNN Double 6.9 / 12 254 – 750 Modular 50
HMD01.1N-W0036-A-07-NNNN Double 20 / 36 254 – 750 Modular 75
HMS01.1N-W0020-A-07-NNNN Single 20-Oct 254 – 750 Modular 50
HMS01.1N-W0036-A-07-NNNN Single 18 / 36 254 – 750 Modular 75
HCS02.1E-W0028-A-03-NNNN Single (converter + supply) 14 / 28 200 – 500 AC (direct) Integrated (Multi-Ethernet) 90
Error Code Meaning
F8022 Encoder 1 signals incorrect (amplitude/phase outside limits)
F8023 Mechanical link fault between motor and encoder (loose coupling or broken shaft connection) 
F8025 DC-bus over-voltage detected in the power section 
F8028 Over-current in the power section (short-circuit or stall) 
F8064 Interruption of one or more motor phases (open winding/cable) 
F8070 +24 V control-supply error (voltage outside tolerance) 
F8091 Power section reported as defective during self-test
F8100 Error during initialization of parameter handling (corrupt or missing parameters) 
F8120 Invalid control-section / firmware combination detected 
F8135 Velocity threshold exceeded with trend monitoring (overspeed condition) 

Frequently Asked Questions about HMD01.1N-W0020-A-07-NNNN:

Q: What cooling system does HMD01.1N-W0020-A-07-NNNN use?

A: The HMD01.1N-W0020-A-07-NNNN uses an internal air-cooling system through an integrated blower that maintains optimal operating temperature.

Q: What is the DC-bus voltage for HMD01.1N-W0020-A-07-NNNN?

A: The DC-bus nominal voltage for the HMD01.1N-W0020-A-07-NNNN is 700VDC, which is ideal for high-powered industrial applications requiring efficient energy usage.

Q: What is the operational altitude of HMD01.1N-W0020-A-07-NNNN?

A: The HMD01.1N-W0020-A-07-NNNN can operate at an altitude of up to 1000 meters, maintaining stable performance at higher elevations.

Q: What is the temperature range of HMD01.1N-W0020-A-07-NNNN?

A: The HMD01.1N-W0020-A-07-NNNN operates within a temperature range of 0 to 40 degrees C, ensuring reliable performance in moderate temperature conditions.

Q: What is the purpose of the overvoltage limiters in HMD01.1N-W0020-A-07-NNNN?

A: The overvoltage limiters protect the unit by discharging excess voltage above 33 volts, preventing potential damage to internal components.


Internal Product Review

  • ‘‘The Bosch Rexroth HMD01.1N-W0020-A-07-NNNN provides exceptional motor control with dual outputs, allowing it to operate two motors independently. Its 700VDC nominal voltage, 20A peak current, and integrated air cooling system ensure reliable performance. The IP20 protection and overvoltage limiters enhance system safety.’’