4.95 based on 202 reviews

🙶 Product was as advertised, got the machine back up and running at a fraction of OEM price. Delivered on ti... 🙷

EEA-PAM-520-A-14 Vickers

No Tariffs On US Orders
  • Rated 4.5 (73 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Vickers EEA-PAM-520-A-14 is a power amplifier from the EEA-PAM Power Amplifiers series using the Eurocard format. It provides one ramp function and a maximum solenoid current of 1.6 Amps, and is compatible with KDG4V-3S, KTG4V-3S, and KDG5V-5/7/8 valves. The amplifier supports coil power of 18 Watts and coil resistance of 7.3 Ohms.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The EEA-PAM-520-A-14 power amplifier is manufactured by Vickers as part of the EEA-PAM Power Amplifiers series. Supplied in a plug-in card format, it interfaces between electronic motion controllers and proportional hydraulic valves, converting low-level command voltages into regulated coil current. In industrial automation systems, the card stabilizes valve spool position, allowing repeatable flow or pressure regulation without the need for separate discrete drive components. By regulating coil current directly, it also helps keep valve response stable during repeated motion cycles and changing hydraulic loads.

The amplifier uses a Eurocard outline, allowing it to slide directly into 19-inch sub-racks that already carry system backplanes. Its current output is limited to 1.6 A, matching the magnetics of the supported proportional solenoids and helping prevent coil overheating. Internally, the driver references the valve winding with a 29 mH inductance so the control loop can account for the natural electrical time constant of the load. A series sense network monitors the winding’s 7.3 Ω resistance to compensate for temperature-related changes in coil impedance. For motion profiles that need controlled acceleration or deceleration, the board provides a One Ramp function with a single adjustable rise and fall time to shape the current transition and reduce hydraulic shock.

In operation, the amplifier can deliver up to 18 W to the connected solenoid without exceeding its thermal envelope, maintaining steady actuation during continuous cycles. It is pre-tuned for proportional valves such as KDG4V-3S, KTG4V-3S, KDG5V-5/7/8, so field wiring mainly involves jumper selection rather than gain recalibration. The board can also be used with machinery built to EN427 models. The build code carries the coil identifier H, indicating compatibility between the valve’s magnetic components and the amplifier output characteristics.

Amplifier Format
Eurocard
Coil Id
H
Coil Inductance
29 mH
Coil Power
18 W
Coil Resistance
7.3 Ohm
En Variant Use
EN427 Models
Max Solenoid Current
1.6 A
Ramp Function
One Ramp
Valve Compatibility
KDG4V-3S, KTG4V-3S, KDG5V-5/7/8
  • EEA PAM 520 A 14
  • EEA-PAM-520-A-l4
  • EEAPAM520A14
Symptom / LED Pattern Likely Cause (What it Means) Recommended Corrective Action
All panel LEDs dark 24 V DC supply absent or reversed Verify 24 V (18-32 V) at back-plane, check fuse/polarity, then repower card.
24 V OK LED on, but +15 V logic LED off Internal logic regulator fault Measure Vlogic test-point; if 0 V replace regulator or whole card.
Yellow “Output-enable” LED dark although z24 > +10 V Enable line < 6 V, broken PLC output or wiring Trace enable wire, restore > +10 V to pin z24 and reset card. 
Red “Overload” LED lit Solenoid current > 1.5 A (shorted coil) Measure coil R; repair wiring, fit correct valve coil; card auto-resets.
Only Channel B responds (dual-out card) Channel A gain set to zero or set-min pot fully CCW Read monitor jack a18; readjust gain / set-min for Channel A.
Ramp pot turns but valve still jerks Ramp-bypass link b12-b20 closed Open link or wire it to PLC control to re-enable ramp generator.
PWM dither absent – spool sticks Factory dither jumper missing Re-install jumper per ML-9046, or enable dither via test jack.
Output drifts as card warms Temperature drift on zero/gain Allow 15 min warm-up; re-zero set-minimum; segregate signal cables from power. 
Low-supply trip < 19 V (all LEDs drop) Undersized 24 V PSU or long cable drop Upgrade PSU ≥ 40 W, use 2.5 mm² wiring to cut losses. 
Valve unresponsive after card swap Ramp time still at 20 ms factory default Turn ramp pot CW (0.02 – 2 s range) and verify with pressure gauge.
Model Typical Application / Valve Family Command Inputs Ramp Generator Diagnostics / LEDs Max Coil Current (A)
EEA-PAM-520-A-14 Dual-channel control for two proportional coils or 2-stage valve 0–10 V ×2, 0–20 mA ×1 Single adjustable (20 ms – 2 s) 24 V, 15 V, Enable, Overload 1.5 × 2
EEA-PAM-513-A-32 Mid-size directional valves (KDG4V-3*) 0–10 V ×5 / 0–20 mA Single adjustable Power, Ramp, Fault 1.5
EEA-PAM-525-A-32 High-flow KDG4V-5 valves 0–10 V ×5 / 0–20 mA Single adjustable Low-V, Overload 1.6
EEA-PAM-535-A-32 KFD/TG4V-5 pressure/flow valves 0–10 V ×5 / 0–20 mA Single adjustable Power, Overload 1.6
EEA-PAM-561-A-14 KDG5V-5/7 spool valves with LVDT ±10 V Dual independent ↑/↓ LVDT-fail, Overload 1.8
EEA-PAM-571-A-14 KFDG5V servo spools ±10 V + ±15 V ref Four-quadrant (acc/dec each dir.) LVDT, Overload, Watchdog 2.5

Indicator / Condition

What It Means

Green “24 V” LED off

No or low 24 V DC feed reaching the card (supply < 20 V or wiring fault).

Green “15 V” LED off

On-board logic rail missing – internal regulator or card failure.

Yellow “Output-enable” LED dark although z24 is ≥ 10 V

Enable line actually < 6 V at pin z24 (broken PLC output / wiring).

Red “Overload” LED lit

Solenoid current > ≈1.5 A – shorted coil or wrong valve type.

Card drops out when supply dips below 19 V

Low-supply protection triggered; PSU underrated or long cable run.

Command signal present but no valve response

Set-minimum or Gain pots fully CCW → zero output.

Ramp pot has no effect / valve jerks

Ramp-bypass link b12–b20 left closed, disabling ramp generator.

PWM dither absent

Factory dither jumper removed, causing spool stiction.

Output drifts with temperature rise

PCB zero/gain drift; requires 15 min warm-up and re-zero, improve shielding.

Ramp time wrong after card swap

Replacement still at 20 ms factory default; adjust ramp pot (0.02 – 2 s).

Frequently Asked Questions about EEA-PAM-520-A-14:

Q: What mounting format does the EEA-PAM-520-A-14 power amplifier utilize?

A: The EEA-PAM-520-A-14 amplifier uses a Eurocard format for mounting, making it suitable for standardized industrial racks.

Q: What is the maximum solenoid current output for the EEA-PAM-520-A-14?

A: This amplifier supports a maximum solenoid current of 1.6 A, ensuring proper operation with compatible valves.

Q: Which valve models can be used with the EEA-PAM-520-A-14 amplifier?

A: The EEA-PAM-520-A-14 is compatible with KDG4V-3S, KTG4V-3S, and KDG5V-5/7/8 valves.

Q: What is the coil resistance value for the EEA-PAM-520-A-14 amplifier?

A: The coil resistance specified for this amplifier is 7.3 Ohm.

Q: What type of ramp function does the EEA-PAM-520-A-14 provide?

A: This model features a single ramp function, allowing gradual transition of output to protect hydraulic components.


Internal Product Review

  • ‘‘The EEA-PAM-520-A-14 is a Vickers power amplifier in Eurocard format built for EN427 models. Compatibility with KDG4V-3S, KTG4V-3S, and KDG5V-5/7/8 valves, along with a 1.6 A maximum solenoid current, makes this unit a strong choice for precise hydraulic control.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo