EEA-PAM-511-A-32
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
-
In-Stock, Ships 3-5 Days
Power Amplifier Card Series for Proportional Control Valves manufactured by Vickers. This EEA-PAM-511-A-32 Card is For Proportional Valve ECG-02 and has a Power Supply Nominal Voltage of 24V DC x 50W.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Partner with Vickers and use their efficient, highly customizable, and high-quality hydraulic components to produce long-term results. The integration of their products into any system is easy and totally customizable allowing for many types of applications. Their line of power amplifiers and proportional valves affords plenty of options to drive your hydraulic systems seamlessly. Each power amplifier is engineered to correspond to a unique proportional valve (or several) for a tailored fit. Rather than offering confusing and complicated product systems, Vickers ensures that they provide clear solutions to integrate into any system.
The EEA-PAM-511-A-32 power amplifier is for use with proportional valve ECG-02. This combination can also be used with several additional components for extra flexibility. The power amplifier can accept inputs of current or voltage, and like all of Vickers’ products is easily adjusted to fit your system.
A driving force behind Vickers’ designs is the many safety checks and contingency features. This helps avoid downtime and loss of productivity due to troubleshooting and adjustments, which is imperative for industrial systems to save both time and money. Trust Vickers to provide you with tough components that stand out in any industrial application – without compromise.
Frequently Asked Questions about EEA-PAM-511-A-32:
Q: What are some of the amplifier features?
A: Amplifier features include front panel with adjustments, LED display and monitor points.
Q: Does the amplifier support plug-in modules?
A: The amplifier supports plug-in modules for additional functions.
Q: What are the installation dimensions?
A: The dimensions are: 122.4 mm height, 40.3 mm width, and 175.24 mm depth.
Q: How can you tune the amplifier for the proportional valve?
A: You can set the zero point, gain and deadband compensation to tune the amplifier.
Q: How can you measure the command signal?
A: Monitor points on the front panel of the amplifier allow measurement of the conditioned command signal, solenoid current, and LVDT signal.