4.95 based on 202 reviews

🙶 First-time customer with Wake Industrial. The ordering process was completely seamless. The part that we o... 🙷

16.F4.C1G-3420 KEB
16 Kilohertz IP20 Frequency Inverter

In-Stock, Ships 3-5 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The 16.F4.C1G-3420 is a KEB F4 Combivert frequency inverter with 3-phase input and 15 kW motor capacity. IP20 protection and 33 A nominal output current make the unit a strong fit for controlled cabinet installations needing dependable drive performance. The 16 kHz maximum switching frequency is a standout advantage for demanding motor applications.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 16.F4.C1G-3420 frequency inverter is produced by KEB as part of the F4 Combivert Frequency Inverters series. As an AC drive, it converts fixed-frequency three-phase mains power into a variable voltage and frequency output, enabling closed-loop speed control of induction or synchronous motors in automated machinery. By integrating programmable acceleration ramps and fault monitoring, the unit acts as a decentralized motion node that relieves the central PLC of direct motor control tasks. This arrangement allows the connected motor to start, run, and decelerate in a controlled manner without requiring a separate external speed-control device for basic drive functions.

The drive uses a three-phase electrical supply and draws a nominal input current of 36.5 A, so incoming conductors with a cross section of 10 mm² and a 50 A mains fuse satisfy the stated wiring requirements. Under rated conditions, it delivers 23 kVA of apparent power and an output current of 33 A to a motor rated up to 15 kW, which suits mid-range pumps, conveyors, and similar industrial loads. The internal overcurrent channel trips at 49.5 A during short-time peaks, while normal switching occurs at a carrier frequency of 4 kHz to balance thermal loading and audible noise. Its IP20 enclosure is intended for control-cabinet installation, where the housing is protected from accidental contact and relies on the surrounding panel environment for proper operation.

For applications that place higher priority on motor acoustics, the modulation frequency can be increased to 16 kHz, which can help smooth motor current if thermal limits are observed. During rapid deceleration, regenerated energy is directed to a 42 Ω braking resistor to limit DC-bus overvoltage and maintain stable operation. A shielded motor cable length of up to 100 m is permitted without additional output filters, which supports machines where the motor is mounted at a distance from the cabinet. The inverter is assigned to climatic class 3K3 for typical indoor industrial conditions, and its 10 kg mass supports standard panel mounting without special structural changes.

Climatic Category
3K3
Input Phases
3
Line Cross Section
10 mm²
Max Mains Fuse
50 A
Max Motor Power
15 kW
Max Short-time Current
49.5 A
Max Switching Freq
16 kHz
Nominal Input Current
36.5 A
Oc Tripping Current
59.4 A
Output Nominal Current
33 A
Output Nominal Power
23 kVA
Protection Rating
IP20
Rated Switching Freq
4 kHz
Shielded Motor Cable
100 m
Typical Braking Resistor
42 Ω
Weight
10 kg

Frequently Asked Questions about 16.F4.C1G-3420:

Q: What is the maximum motor power supported by the 16.F4.C1G-3420 frequency inverter?

A: The 16.F4.C1G-3420 inverter supports up to 15 kW of maximum motor power output.

Q: How many input phases does the 16.F4.C1G-3420 inverter require?

A: This model is designed to operate with three input phases.

Q: What is the protection rating of the 16.F4.C1G-3420 inverter?

A: The protection rating for this device is IP20, indicating basic protection against solid objects.

Q: What is the maximum short-time current of the 16.F4.C1G-3420 inverter?

A: The maximum short-time current the 16.F4.C1G-3420 can handle is 49.5 A.

Q: What is the maximum length of shielded motor cable supported by the 16.F4.C1G-3420 inverter?

A: This model accommodates shielded motor cables up to 100 meters in length.

Fault Code Text Display / Meaning Typical Cause(s) Quick Corrective Action
E.UP Undervoltage (DC-link) Input voltage too low/unstable, one phase missing, long supply leads Check mains phases & voltage, correct wiring, lengthen accel/decel ramps
E.OP Overvoltage (DC-link) High line voltage, regen energy during fast decel, brake resistor open Add/verify braking resistor, lengthen decel ramp, check mains level
E.UPh Phase Missing One supply phase absent or heavily sagging Verify 3-phase feed, tighten terminals, inspect fuses/contactors
E.OC Over-current Short-circuit or ground fault on motor leads, accel ramp too short Insulate/megger motor cable, lengthen accel ramp, test motor windings
E.OHI / E.OH Heatsink Over-temperature Fan clogged, ambient > 40 °C, airflow blocked Clean heatsink & fan, improve cabinet ventilation, allow cooldown
E.dOH Motor PTC Over-temperature Motor overloaded, PTC > 1650 Ω, sensor cable break Reduce load, check motor fan, test PTC wiring, allow cooling
E.OL Drive Overload Continuous high load beyond rating, poor tuning Verify load sizing, retune PI loops, up-size drive if required
E.EF External Fault Digital input configured as “External Fault” became active Trace external interlock chain, reset once input returns to normal
E.EEP EEPROM Error Parameter memory corrupt / write failure Cycle power, try parameter save; if persistent replace control board
E.PU Power-circuit Fault Internal power unit, fan or gate-drive problem Inspect fans & power board, check DC bus, contact KEB service
Part Number Voltage Class (3~) Rated Power Continuous Output Current* Approx. Size (H × W × D mm)
16.F4.C1G-3420 400 V (G-frame) 15 kW 320 × 180 × 260 mm
16.F4.C1G-3421 400 V 12 kW 30 A 170 × 340 × 255 mm
16.F4.C1G-3440 400 V 15 kW 33 A 170 × 340 × 255 mm
16.F4.C1G-M440/2.2 400 V 15 kW (23 kVA) 33 A N/S
16.F4.C1H-3280 230 V 15 kW 66 A 297 × 340 × 255 mm
16.F4.C1H-4A01 305-500 V ≈15 kW (23 kVA) 33 A N/S
Code Meaning shown on keypad
E.UP DC-link undervoltage
E.OP DC-link overvoltage
E.UPh Phase failure
E.OC Over-current
E.OH Power-module over-temperature
E.dOH Motor PTC over-temperature
E.OL Drive overload (I²t)
E.EF External fault input active
E.EEP EEPROM defective
E.PU Power-circuit fault
Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo