KDA 3.3-150-3-A00-W1 is a spindle drive. It works with 2AD and 1MB motors. Its rated output is 150 Amps.

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

KDA 3.3-150-3-A00-W1 is a main spindle drive. Bosch KDA drives are used for control of 2AD asynchronous motors and 1MB frameless spindle motors. A microcomputer carries out drive control, monitoring and diagnostics. This is aided by an accurate measurement of motor rotor position over the entire speed range. In addition to speed control, KDA drives provide a high degree of internal position control. Adaptation of motors and operation modes is done through parametrization, which is performed by an integrated input and display unit. The KDA 3.3-150-3-A00-W1 drive is designed for forced air cooling. It is equipped with a blower that requires 220 Volts AC external supply. DC bus voltage of the drive is 300 Volts DC. Its rated current output is 150 Amps and the continuous current output is 90 Amps.

The control electronics consume 1.6 Amps at 24 Volts DC and 160 milliamps at 15 Volts DC measuring voltage. Weight of the spindle drive unit is 17.4 kilograms. The blower unit weighs 4.2 kilograms. Weight of the mechanical mounting kit is 1.7 kilograms. The ambient temperature required for rated output is 5 to 45 degrees Celsius. The permitted maximum temperature with reduced nominal data is 55 degrees Celsius. Bosch recommends -30 to 85 degrees Celsius ambient temperature for storage and transport. The specified installation elevation without reduction of nominal data is 0 to 1000 meters. Protection category of the drive housing is IP10. The unit is designed for vertical mounting inside a suitable cabinet. Only trained personnel with relevant qualifications should handle and install the KDA 3.3-150-3-A00-W1 spindle drive. Failure to implement manufacturer instructions can lead to equipment damage and injury to personnel.

Click here to learn more about the uses for the KDA 3.3-150-3-A00-W1 and other Indramat Spindle Drives. 

Additional encoder input
No
Additional interface
No
Blower supply
220 Volts AC
Cooling
Blower
Current rating
150 Amps
DC bus voltage
300 Volts DC
Manufacturer
Bosch Rexroth
Mounting
Vertical
Product type
Main spindle drive
Speed command
Analog
  • KDA 3.3 150 3 A00 W1
  • KDA 3.31503A00W1
  • KDA- 3.3-150-3-A00-W1
Typical fault code / symptom What it usually means Quick corrective action
F205 — switching to un-initialised operating mode Required mode not stored in parameters S-0-0032…35 Enter the correct spindle-mode parameters, save, then issue Reset Class 1 Diagnostics or power-cycle drive. 
F218 — heat-sink over-temperature Internal heat-sink > allowed limit Clean or replace heat-sink blower, improve cabinet airflow, wait < 45 °C, then reset. 
F219 — motor over-temperature 2AD/1MB motor thermistor tripped (≈ 155 °C) Reduce load, check external motor fan, allow full cool-down before re-enable. 
F220 — bleeder-resistor over-temperature Internal regen resistor overheated Add/ex-size external brake resistor or lengthen decel ramps; clear when cool. 
F226 — DC-bus under-voltage Bus < ~270 V while drive enabled Check KDV power supply and bus cabling for brown-outs; reset after mains OK. 
F228 — excess following-error Spindle cannot track speed demand Reduce accel/dec ramp, inspect mechanics for drag, retune velocity loop. 
F229 — encoder-quadrant error Resolver/encoder plausibility fault Inspect feedback cable & shielding, replace encoder or interface if repeat. 
F230 — encoder-frequency too high Spindle speed > encoder interface limit Limit top speed or fit lower-PPR encoder; clear and restart. 
F233 / 34 — +24 V control-supply error / E-Stop active External 24 V lost (often via E-Stop chain) Restore 24 V, clear E-Stop, then perform Class 1 Reset. 
Display dark & blower runs continuously Drive in thermal or HW self-protection Measure DC-bus (≈ 300 V) and 24 V, check blower supply (220 VAC), replace drive if self-test fails.
Model Series / design Rated current (A) DC-bus voltage (V) Cooling Notable feature
KDA 3.3-150-3-A00-W1 3.3 150 300 Forced (heat-sink blower, 220 VAC) Highest-current 3.3 design
KDA 3.2-150-3-A00-W1 3.2 150 300 Forced Earlier firmware line 3.2, otherwise drop-in
KDA 3.2-100-3-A00-W1 3.2 100 300 Forced 100 A version for mid-size spindles
KDA 3.3-050-3-A00-W1 3.3 50 300 Forced Low-current 3.3 for light spindles
KDA 2.1-100-3-A00-W1 2.1 100 300 Forced Older 2.1 hardware, 100 A; same bus
KDA 3.2-150-3-A00-W1 3.2 150 300 Forced Variant with auxiliary encoder input
Error code What it means
F218 Heatsink over-temperature shutdown
F219 Motor over-temperature shutdown (thermistor > 155 °C)
F220 Bleeder-resistor over-temperature
F226 DC-bus undervoltage while drive is enabled
F228 Excessive control deviation (cannot follow command)
F229 Encoder 1 failure – quadrant error
F230 Max. signal frequency of encoder 1 exceeded
F233 External +24 V power-supply error
F234 Emergency-Stop active
F236 Excessive position-feedback difference

Frequently Asked Questions about KDA 3.3-150-3-A00-W1:

Q: Can the unit be used outdoors?

A: The unit can be used outdoors when mounted inside a cabinet.

Q: What is the maximum permitted site elevation with reduced nominal data?

A: The maximum permitted site elevation with reduced nominal data is 5000 meters.

Q: What is the permitted humidity?

A: The permitted humidity is F as per DIN 40 040.

Q: What is the weight of the blower?

A: Weight of the blower is 4.2 kilograms.

Q: What is the weight of the spindle drive?

A: Weight of the spindle drive is 17.4 kilograms.