4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

KDA 3.3-150-3-A00-W1 Bosch Rexroth Indramat

MPN: R911257443

No Tariffs On US Orders
  • Rated 4.5 (38 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat KDA 3.3-150-3-A00-W1 is a spindle drive from the KDA Spindle Drives series with a rated current of 150 Amps and operates with a DC supply voltage of 300 Volts. It features forced cooling through a mounted heatsink blower and is suitable for environments with an ambient temperature range of 5 to 45 degrees Celsius. The drive accepts analogue speed command values and its AC source for the heatsink blower is 220V at 50-60Hz.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 3.3-150-3-A00-W1 belongs to the KDA Spindle Drives series produced by Bosch Rexroth Indramat. As a spindle drive, it converts regulated DC bus power into three-phase output for high-speed machining spindles and coordinates torque, acceleration, and braking through feedback from the motor’s primary encoder. In automated machine tools, this drive forms the axis dedicated to material removal, letting the numerical controller vary spindle speed while keeping operation stable within its thermal and electrical limits.

The power stage is supplied from a DC bus held at 300 VDC, giving the internal inverter enough headroom for rapid vector control. Continuous output capability reaches 150 A, so the drive can run large-frame induction or synchronous spindles during heavy cuts. Thermal energy is removed by a mounted heat sink blower; air is pushed directly across the fins, and the enclosure uses forced cooling to keep semiconductor junctions below their intended operating temperature in enclosed cabinets. The blower motor takes its single-phase supply from 220 V/50–60 Hz, allowing straightforward connection to auxiliary power in most plants. Control electronics include a standard analog velocity input, but the housing omits optional fieldbus and second-encoder boards when only basic spindle feedback is needed.

The unit operates within an ambient range of 5 to 45 °C; outside this range, component stress or condensation may occur. Installation is limited to 1000 m above sea level so cooling air density and insulation behavior remain consistent. Speed reference comes from an analog ±10 V signal, aligning the drive with legacy CNC controllers that regulate spindle speed through voltage scaling. The unit is Series 3, indicating its product generation. With no additional interface option and no secondary encoder port, the model is intended for dedicated spindle axes in milling, turning, or grinding centers.

AC Source for Heatsink Blower
220V/50-60Hz
Additional Interfaces
No Additional Interface Option
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product type
Spindle Drive
Rated Current
150 A
Second Encoder Input
Does not feature additional input
Series
3
Speed Command Value
Analogue
  • KDA 3.3 150 3 A00 W1
  • KDA 3.31503A00W1
  • KDA- 3.3-150-3-A00-W1
Typical fault code / symptom What it usually means Quick corrective action
F205 — switching to un-initialised operating mode Required mode not stored in parameters S-0-0032…35 Enter the correct spindle-mode parameters, save, then issue Reset Class 1 Diagnostics or power-cycle drive. 
F218 — heat-sink over-temperature Internal heat-sink > allowed limit Clean or replace heat-sink blower, improve cabinet airflow, wait < 45 °C, then reset. 
F219 — motor over-temperature 2AD/1MB motor thermistor tripped (≈ 155 °C) Reduce load, check external motor fan, allow full cool-down before re-enable. 
F220 — bleeder-resistor over-temperature Internal regen resistor overheated Add/ex-size external brake resistor or lengthen decel ramps; clear when cool. 
F226 — DC-bus under-voltage Bus < ~270 V while drive enabled Check KDV power supply and bus cabling for brown-outs; reset after mains OK. 
F228 — excess following-error Spindle cannot track speed demand Reduce accel/dec ramp, inspect mechanics for drag, retune velocity loop. 
F229 — encoder-quadrant error Resolver/encoder plausibility fault Inspect feedback cable & shielding, replace encoder or interface if repeat. 
F230 — encoder-frequency too high Spindle speed > encoder interface limit Limit top speed or fit lower-PPR encoder; clear and restart. 
F233 / 34 — +24 V control-supply error / E-Stop active External 24 V lost (often via E-Stop chain) Restore 24 V, clear E-Stop, then perform Class 1 Reset. 
Display dark & blower runs continuously Drive in thermal or HW self-protection Measure DC-bus (≈ 300 V) and 24 V, check blower supply (220 VAC), replace drive if self-test fails.
Model Series / design Rated current (A) DC-bus voltage (V) Cooling Notable feature
KDA 3.3-150-3-A00-W1 3.3 150 300 Forced (heat-sink blower, 220 VAC) Highest-current 3.3 design
KDA 3.2-150-3-A00-W1 3.2 150 300 Forced Earlier firmware line 3.2, otherwise drop-in
KDA 3.2-100-3-A00-W1 3.2 100 300 Forced 100 A version for mid-size spindles
KDA 3.3-050-3-A00-W1 3.3 50 300 Forced Low-current 3.3 for light spindles
KDA 2.1-100-3-A00-W1 2.1 100 300 Forced Older 2.1 hardware, 100 A; same bus
KDA 3.2-150-3-A00-W1 3.2 150 300 Forced Variant with auxiliary encoder input
Error code What it means
F218 Heatsink over-temperature shutdown
F219 Motor over-temperature shutdown (thermistor > 155 °C)
F220 Bleeder-resistor over-temperature
F226 DC-bus undervoltage while drive is enabled
F228 Excessive control deviation (cannot follow command)
F229 Encoder 1 failure – quadrant error
F230 Max. signal frequency of encoder 1 exceeded
F233 External +24 V power-supply error
F234 Emergency-Stop active
F236 Excessive position-feedback difference

Frequently Asked Questions about KDA 3.3-150-3-A00-W1:

Q: How is the KDA 3.3-150-3-A00-W1 spindle drive cooled?

A: This drive uses a forced cooling system with a mounted heatsink blower.

Q: What is the rated current of the KDA 3.3-150-3-A00-W1 spindle drive?

A: The rated current for this spindle drive is 150 A.

Q: What is the operating ambient temperature range for this model?

A: The permitted ambient temperature range for operation is 5 to 45 degrees Celsius.

Q: What type of speed command input does the KDA 3.3-150-3-A00-W1 use?

A: This drive accepts analogue speed command values.

Q: What is the maximum installation elevation for the KDA 3.3-150-3-A00-W1 spindle drive?

A: The maximum allowed installation elevation is 1000 meters above sea level.


Internal Product Review

  • ‘‘The KDA 3.3-150-3-A00-W1 spindle drive from Bosch Rexroth Indramat features forced cooling with a mounted heatsink blower, ensuring reliable operation in demanding environments. Rated for 150 A and a DC supply voltage of 300 VDC, this unit delivers high performance for spindle applications. The drive stands out for its consistent cooling and capacity for continuous heavy-duty use.’’