HVR03.2-W045N

MPN: R911190005

No Tariffs On US Orders
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
    In-Stock, Ships Today

Preparing your secure checkout page...

HVR03.2-W045N is a power stage. It converts AC input to DC output. The input voltage range is 380 to 480 Volts AC.

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

HVR03.2-W045N is a power stage. It is part of the HVR series from Bosch Rexroth. Its main function is converting AC input to DC output. The input voltage range is 380 to 480 Volts AC. The unit requires three-phase AC input at 50 to 60 Hertz line frequency. DC bus voltage of the power stage is 750 Volts DC. The DC bus continuous power output is 30 kilowatts. The DC bus peak output for 0.3 seconds is 135 kilowatts. The peak bleeder power is 80 kilowatts. The maximum regenerated energy is 100 kWs. The power loss at maximum continuous output is 626 Watts. The basic losses are 175 Watts. The power loss per kilowatt DC bus continuous power are 24 W/kW. Weight of the HVR03.2-W045N power stage is 24 kilograms.

The control voltage supply is 380 to 480 Volts AC (three-phase, 50/60 Hertz). Power draw of the unit at maximum load is 850 VA. The control voltage output is 500 Watts. Bosch recommends 5 to 45 degrees Celsius ambient temperature for optimal output. The maximum permissible ambient temperature with derated data is 55 degrees Celsius. Storage temperature for the HVR03.2-W045N power stage is ?30 to 85 degrees Celsius. The installation elevation without power reduction is maximum 1000 meters above mean sea level. The maximum permissible humidity during operation is 95%. The permissible absolute humidity is 25 grams per cubic meters of air. Protection category of the power stage is IP10 as per DIN 40 050. Therefore it can be used indoors, preferable when mounted inside a cabinet. Condensation is not permitted on the unit. To prevent accidents and injuries, only trained personnel should work with the unit.

Clearance
300 millimeters
Control voltage
380 to 480 Volts
DC bus voltage
750 Volts DC
Input voltage
380 to 480 Volts AC
Max power draw
850 VA
Max regen energy
100 kWs
Mounting
Vertical
Product type
Power stage
Protection rating
IP10
Weight
24 kilograms
  • HVR032W045N
  • HVR03 2 W045N
  • hvr03.2-w045n
Fault code / LED text What it usually means Corrective action
F218 — HEATSINK OVERTEMP. Internal blower can’t keep the rectifier cool (> ≈85 °C) Clean / replace fan, improve cabinet airflow, wait ≤ 45 °C, then Class-1 reset.
F320 — BLEEDER OVERLOAD Too much braking energy for the built-in resistor Lengthen decel ramps or add an external brake resistor; clear when cool.
F380 — SHORT-TO-GND P.S.U. Ground-fault in supply, drives or motor cable Megger cabling & motor, isolate the short, then reset.
F381 — MAINS FAILURE Input phases dropped while DC-bus active Check incoming breaker, contactor & wiring; restore mains, reset.
F382 — MAINS PHASE LOSS One of the three AC phases missing Inspect L1 / L2 / L3 fuses and terminals, correct wiring.
F383 — LINE VOLTAGE FAULT AC line outside 380-480 V ±10 % Verify plant transformer taps or fit stabiliser; clear fault.
F384 — CONNECTION ERROR PSU X5/X8 phase sequence wired out-of-order Swap leads so X5-U ↔ X8-1, X5-V ↔ X8-2, X5-W ↔ X8-3 match.
F385 — LINE FREQ. FAULT Mains frequency ≠ 50–60 Hz ±2 % Check supply generator, stabilise to 50/60 Hz, reset drive.
F226 — DC-BUS UNDERVOLTAGE KDV/HVR bus < ≈ 650 V while enabled Look for brown-outs, loose bus bars; restore 3× AC mains.
F870 — +24 V DC ERROR Control-supply rail sagged below 22 V Size PSU ≥ 300 W, tighten terminals X31, retest.
Model Continuous DC-bus power Peak power (0.3 s) Max regen energy Input voltage Notes
HVR03.2-W045N  45 kW 135 kW 80 kWs 380-480 V AC 2nd-gen, internal blower
HVR03.2-W045N/S202 45 kW 135 kW 80 kWs 380-480 V AC Same ratings, special firmware S202
HVR03.2-W045N/S200 45 kW 135 kW 80 kWs 380-480 V AC Variant with enhanced diagnostics
HVR03.1-W045N 30 kW 135 kW 100 kWs 380-480 V AC 1st-gen design, slower control
HVR03.1-W045N/S025 75 kW 135 kW 80 kWs 380-480 V AC High-current retrofit module
HVR02.2-W025N 25 kW 75 kW 75 kWs 380-480 V AC Compact 25 kW unit for smaller DIAX04 racks
Error code What it means
F218 Heatsink over-temperature shutdown
F320 Bleeder overload (excess regenerative energy)
F380 Short-to-ground in power supply, drive or motor cable
F381 Mains failure (one or more AC phases missing)
F382 Phase-loss fault on the mains supply
F383 Line-voltage fault (voltage outside 380-480 V ±10 %)
F384 Connection-error PSU (phase sequence incorrect)
F385 Line-frequency fault (≠ 50–60 Hz ±2 %)
F226 DC-bus undervoltage detected while enabled
F870 +24 V DC control-voltage error

Frequently Asked Questions about HVR03.2-W045N:

Q: What is the main function of the power stage?

A: The power stage converts AC input to DC output.

Q: Can the power stage supply power to multiple drives?

A: The power stage can deliver power to multiple drives.

Q: What is the operating temperature?

A: The operating temperature is 5 to 45 degrees Celsius.

Q: What is the storage and transport temperature?

A: The storage and transport temperature is -30 to 85 degrees Celsius.

Q: What is the optimal site elevation?

A: The optimal site elevation is 0 to 1000 meters.


Internal Product Review

  • ‘‘HVR03.2-W045N is a power stage that provides power for multiple drive units. It has an input voltage of 380 to 480 VAC and a max power draw of 850 A. This wide power range makes it a versatile power supply unit.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo