HMS01.1N-W0070-A-07-NNNN Bosch Rexroth Indramat

MPN: R911295326

No Tariffs On US Orders
  • Rated 4.4 (95 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships Today

Preparing your secure checkout page...

The Bosch Rexroth Indramat HMS01.1N-W0070-A-07-NNNN is part of the HMS Axis Inverters series, featuring a nominal DC bus voltage of 700 V DC. The inverter provides a rated maximum current of 70 Amps and uses internal air cooling with an integrated blower. It is designed with an IP20 protection class.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HMS01.1N-W0070-A-07-NNNN belongs to the HMS Axis Inverters series produced by Bosch Rexroth Indramat. As a single-axis inverter, it interfaces between the common DC bus of a modular Rexroth drive system and the servo or induction motor on one machine axis. Its primary function in industrial automation is to regulate torque, speed, and position by converting the shared DC link energy into a controlled three-phase output, enabling coordinated motion in packaging lines, material-handling cells, and machine tools.

This inverter uses Internal Air with Integrated Blower cooling, so the built-in fan draws cabinet air across heat-generating components to maintain permissible temperatures without external ducting. The enclosure carries an IP20 protection class, indicating finger-safe access yet requiring installation inside a control cabinet for dust and liquid shielding. A rated output of 70 A allows the unit to supply high acceleration currents to midsize servo motors while still staying within its thermal limits. The power stage is energized from a shared link operating at DC 700 V; this voltage level supports fast motor dynamics and keeps conductor sizes moderate. For auxiliary circuitry, the internal power supply is Not Equipped, so an external 24 V source must be provided for logic, I/O, and blower startup during mains outages.

Hardware identification is clarified by Design Version 1 and Line Version 1, ensuring firmware and option cards are chosen for the correct build revision. The product code also embeds the family identifier HMS, which groups this axis inverter with other Rexroth modular drives that share identical communication protocols and DC bus connectors. Finally, the branding Bosch Rexroth Indramat guarantees compatibility with the company’s safety modules, regenerative power supplies, and motion controllers used throughout automated production lines.

Cooling Mode
Internal
Cooling Type
Internal Air with Integrated Blower
Design Version
1
Internal Power Supply
Not Equipped
Line Version
1
Nominal DC Bus Voltage
DC 700 V
Output Current
42.4 A
Output Voltage
0 to 500 VAC
Product Type
HMS
Protection Class
IP20
Rated Control Voltage
24 V
Rated Input Voltage
254 to 750 V DC
Rated Maximum Current
70 A
Rated Power Consumption
16 W
Short Circuit Current Rating
42000 A rms
  • HMS 01.1N-W0070-A-07-NNNN
  • HMS01-1N-W0070-A-07-NNNN
  • HMS01.1N-W0070
  • HMS011NW0070A07NNNN
  • HMS1.1N-W0070-A-07-NNNN
  • HMSO1.1N-W0070-A-07-NNNN
  • HMS01 1N W0070 A 07 NNNN
  • hms01.1n-w0070-a-07-nnnn
  • HMS1.1N-W7-A-7-NNNN
  • hms011nw0070a07nnnn
  • HM501.1N-W0070-A-07-NNNN
  • HMS0I.1N-W0070-A-07-NNNN
  • HMS01.IN-W0070-A-07-NNNN
  • HMS01.1N-WO070-A-07-NNNN
  • HMS01.1N-W0O70-A-07-NNNN
  • HMS01.1N-W007O-A-07-NNNN
  • HMS01.1N-W0070-A-O7-NNNN
  • HM5OI.IN-WOO7O-A-O7-NNNN
  • HMS01.1N-W070-A-07-NNNN
  • HMS01.1N-W007-A-07-NNNN
  • HMS01.1N-W0070-A-7-NNNN
  • HMS01.1NW0070-A-07-NNNN
  • HMS01.1N-W0070A-07-NNNN
  • HMS01.1NW0070A-07-NNNN
Fault / Error Code What it Means Recommended Corrective Action
F2019 Motor-over-temperature shutdown – internal or external sensor reached limit  Reduce load or duty-cycle, verify motor-blower operation and thermistor wiring, allow full cool-down, then reset drive.
F2021 Motor-temperature monitor defective / parameterised incorrectly Check sensor type in IndraWorks, inspect cable continuity; replace faulty thermistor or set correct motor data, then clear fault.
F2028 Excessive deviation – position loop cannot follow command  Lower accel/vel ramps, retune position & velocity loops, inspect mechanics for binding/backlash before re-enabling.
F2100 Invalid access to command-value memory (firmware or MMC issue)  Power-cycle; if fault returns, re-flash firmware or replace MMC/control section and reload project.
F2833 Ground fault detected in the motor line during DC-bus charge Megger motor phases to earth (>5 MΩ), inspect cable & connectors; repair insulation fault, then perform Class 1 Reset.
F4001 Double MST failure – SERCOS master telegram lost twice Verify fibre-optic ring, clean/replace damaged leads, match SERCOS cycle times, then restart network.
F8025 DC-bus over-voltage in the power section  Check that braking resistor is sized/connected; lengthen decel ramps or enable regen supply, reset after voltage normalises.
F8028 Over-current in power section  Inspect motor cable for shorts, verify motor parameters & current limits; test IGBT stage if fault persists.
F8070 +24 V control-supply undervoltage  Measure 24 V rail at X31; tighten terminals, up-size PSU if sagging under load; clear fault and restart.
F8091 Power section defective – internal hardware monitoring trip  Run IndraDrive Diag self-test; if fault re-occurs replace inverter power stage or send for repair.
Model Max Current (A) Continuous Current (A) Cooling Nominal DC-Bus (V) Footprint / Weight
HMS01.1N-W0070-A-07-NNNN  70 42.4 Internal blower 700 440×262×100 mm / 7.9 kg 
HMS01.1N-W0020-A-07-NNNN 20 20 Internal blower 700 5.3 kg 
HMS01.1N-W0054-A-07-NNNN 54 — (max only stated) Internal blower 700 — / — (420 W losses) 
HMS01.1N-W0110-A-07-NNNN 110 68.5 Internal blower 700 11.1 kg 
HMS01.1N-W0150-A-07-NNNN 150 100 Internal blower 700 440×262×150 mm / 12.7 kg 
HMS01.1N-W0210-A-07-NNNN 210 Internal blower 700 18.4 kg 
Error Code Meaning
F218 Drive-amplifier heatsink over-temperature shutdown
F219 Motor over-temperature (thermistor trip)
F226 DC-bus undervoltage detected while drive is enabled
F4001 “Double MST” failure – two consecutive missing SERCOS master sync telegrams
F8022 Encoder 1: signals incorrect (cable/encoder fault)
F8025 Over-voltage in the power section
F8026 HV discharge detected while drive enable is active
F8060 Over-current in the power section
F8070 +24 V DC control-supply undervoltage
F2026 Non-fatal DC-bus undervoltage (supply unit response)

Frequently Asked Questions about HMS01.1N-W0070-A-07-NNNN:

Q: What type of cooling does the HMS01.1N-W0070-A-07-NNNN inverter feature?

A: This model uses internal air cooling with an integrated blower to maintain optimal operating temperature.

Q: What is the nominal DC bus voltage for the HMS01.1N-W0070-A-07-NNNN axis inverter?

A: The HMS01.1N-W0070-A-07-NNNN inverter operates with a nominal DC bus voltage of 700 V for power delivery.

Q: What is the rated maximum current capacity of the HMS01.1N-W0070-A-07-NNNN?

A: This inverter supports a rated maximum output current of 70 A for demanding applications.

Q: What is the protection class of the HMS01.1N-W0070-A-07-NNNN inverter?

A: The HMS01.1N-W0070-A-07-NNNN is designed with an IP20 protection class, which provides basic protection against solid objects.

Q: Does the HMS01.1N-W0070-A-07-NNNN axis inverter come equipped with an internal power supply?

A: This unit does not include an internal power supply as part of its standard configuration.


Internal Product Review

  • ‘‘The HMS01.1N-W0070-A-07-NNNN from Bosch Rexroth Indramat is an HMS Axis Inverter featuring a rated maximum current of 70 A and a nominal DC bus voltage of 700 VDC. Internal air cooling with an integrated blower supports efficient thermal management in enclosed installations. With IP20 protection, this inverter is a strong option for controlled industrial environments.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo