Preparing your secure checkout page...

The Bosch Rexroth Indramat DKC01.3-040-7-FW is part of the DKC Drive Controllers series and is designed as an EcoDrive with a rated current of 40 Amps and a DC-bus nominal voltage of 700 Volts. The unit features a maximum output frequency of 1000 Hz and requires a control voltage of 24 V DC. With dimensions of 360 mm in height, 65 mm in width, and 261 mm in depth, the drive controller weighs 5.7 kg.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The DKC01.3-040-7-FW is a drive controller manufactured by Bosch Rexroth Indramat for the DKC Drive Controllers series. As an EcoDrive unit, it supplies regulated three-phase power to synchronous or induction motors used in industrial automation, coordinating speed and torque commands from a higher-level motion system. This makes it suitable for motion tasks that require controlled motor response, stable speed regulation, and repeatable torque delivery in automated equipment.

The controller operates from a DC bus held at 700 V, enabling energy exchange with regenerated motor power. Its output stage supports a continuous current of 40 A, while the supply side can draw up to 16 A during acceleration. The inverter can deliver line-to-line voltages up to 800 V and switching frequencies up to 1000 Hz, permitting precise commutation of high-speed servo motors. Internal losses remain at 180 W under nominal load, so enclosure ventilation must remove that heat during normal operation. Logic and I/O circuits receive a 24 V DC control input, and this rail also supplies the 40 V DC brake terminal. A ready contact rated for 1 A DC signals drive availability to the PLC, and Interface Option 01 is used for the communication connection in this design version.

The housing measures 360 mm in height, 65 mm in width, and 261 mm in depth, with a mass of 5.7 kg. Bosch Rexroth specifies 150 mm of free space above the heat sink and 80 mm below it so airflow can pass through the cooling fins without obstruction. Continuous operation is permitted up to 45 °C, and with derating the unit can remain active at 55 °C. The control electronics consume only 21 W, which helps limit the load placed on the external 24 V supply. Version 3 of the design uses the same Series 01 front panel layout, which supports consistent connection and mounting within the product line.

Bottom Clearance
80 mm
Brake Terminal Voltage
40 V DC
Continuous Power Loss
180 W
Control Power (base Unit)
21 W
Control Voltage
24 V DC
Control Voltage Input
24 V
Control Voltage Power
21 W
DC-bus nominal voltage
700 V
Depth
261 mm
Design
3
Design Version
3
Height
360 mm
Interface Option
01
Max Ambient Temp
45 °C
Max Ambient Temp (nominal)
45 °C
Max Ambient Temp (reduced)
55 °C
Max Input Current
16 A
Max Output Frequency
1000 Hz
Max Output Voltage
800 V
Power Dissipation (cont.)
180 W
Product Type
EcoDrive
Rated Current
40 A
Ready Contact Max Continuous Current
1 A DC
Reduced-load Ambient
55 °C
Series
01
Top Clearance
150 mm
Weight
5.7 kg
Width
65 mm
  • DKC0130407FW
  • DKC01 3 040 7 FW
  • dkc01.3-040-7-fw
Error Code Fault Description Likely Cause Quick Fix
F207 Switching to uninitialized operation mode Operating mode parameters not set / firmware init error Reparameterize mode & powercycle drive
F218 Heatsink overtemperature shutdown Ambient temp too high, dirty fins, blocked airflow Clean heatsink, restore ventilation, lower cabinet temp
F219 Motor overtemperature shutdown Motor overloaded or temperature sensor fault Reduce load, inspect motor cooling & sensor wiring
F220 Bleeder overload shutdown Regen resistor overheated / undersized Check bleeder sizing & cooling; allow cooldown
F226 Undervoltage in power section Incoming mains too low or DC bus drop Verify supply voltage & wiring; inspect contactors
F228 Excessive position/velocity deviation Mechanical jam or poor tuning Inspect mechanics; retune servo, reduce load
F229 Encoder 1 failure quadrant error Faulty encoder signals or cabling Check encoder connector, cable, replace encoder
F230 Encoder 1 max signal frequency exceeded Motor speed too high or wrong feedback scaling Verify motor data & speed limits
F234 Emergency stop triggered E‑stop circuit opened Reset E-stop, clear fault, verify safety circuit
F248 Low battery voltage Controller backup battery depleted Replace battery, reset date/time if required
Model Rated Current (A) Input Voltage (VAC) DC Bus (VDC) Default Interface
DKC01.3-040-7-FW 40 380“480 700 RS232/485 + Analog/Parallel
DKC01.3-100-7-FW 100 380“480 700 RS232/485 + Analog/Parallel
DKC02.3-040-7-FW 40 200“230 700 SERCOS fibre optic
DKC03.3-100-7-FW 100 300“480 700 Profibus DP
DKC11.3-040-7-FW 40 380“480 700 Multibus (SERCOS/Profibus/CANopen)
DKC01.3-200-7-FW 200 380“480 700 RS232/485 + Analog/Parallel
Code Typical trigger
F207 Drive is powered in a mode whose parameters haven’t been commissioned.
F208 Mismatch between the motor ID stored in the MEM card and the encoder now connected.
F209 Corrupt MEM cassette or “load defaults” executed.
F210 Shorted motor leads or aggressive acceleration profile.
F211 Regeneration without a bleeder resistor or line spikes.
F218 Blocked airflow or cabinet ambient > 40 °C.
F219 Continuous overload or faulty KTY / PTC sensor.
F220 Regeneration energy exceeded bleeder wattage rating.
F226 Brown-outs or an open mains phase.
F228 Mechanical jam, loose coupling, or poor loop tuning.

Frequently Asked Questions about DKC01.3-040-7-FW:

Q: What is the DC-bus nominal voltage of the DKC01.3-040-7-FW controller?

A: The DKC01.3-040-7-FW drive controller operates with a nominal DC-bus voltage of 700 V.

Q: What is the rated current for the DKC01.3-040-7-FW drive controller?

A: This model supports a continuous rated current of 40 A for standard operations.

Q: What is the maximum output frequency of the DKC01.3-040-7-FW?

A: The DKC01.3-040-7-FW has a maximum output frequency of 1000 Hz.

Q: What is the maximum ambient temperature at nominal load for the DKC01.3-040-7-FW?

A: This controller has a maximum ambient temperature of 45 °C under nominal load conditions.

Q: What design version is the DKC01.3-040-7-FW drive controller?

A: The DKC01.3-040-7-FW is listed as Design Version 3 in the product lineup.


Internal Product Review

  • ‘‘The DKC01.3-040-7-FW is a Bosch Rexroth Indramat EcoDrive drive controller designed for precise industrial motion control. A 40 A rated current and 1000 Hz maximum output frequency support responsive performance in demanding servo applications. Stable operation on a 700 V DC bus is a strong technical advantage for high-performance drive systems.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo