The AX8810-0000-0000 is a digital servo drive manufactured by Beckhoff. Part of the AX Digital Servo Drive Series, it features a maximum DC link voltage of 848 V and a protection rating of IP20. The drive measures 230 mm in height and 192 mm in depth. It supports natural convection cooling.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The AX8810-0000-0000, chassis number type is a capacitor module which is meant for increasing the amount of DC link capacitance in Beckhoff servo drive systems. This module is very important in helping the DC link by capturing and cooling voltage spikes caused during motor braking therefore improving overall energy efficiency. Since temporary power is also connected to the motor in case of any interruptions, this regenerative energy is stored in the AX8810 thus limiting the need of the use of brake resistors. This does not only result in the reduction of unnecessary power losses but also leads to a decrease in the overall connected load thus enhancing power usage and the chances of downsizing of fuses.

When using the AX8810, one of the most attractive advantages is its energy efficiency saving potential where frequent brake cycles are required. It makes it possible to activate the brake resistors less frequently thus enabling a constructive distribution of the energies to be captured thereby making the energy consumption of the multi axes systems. The capacity module is rated for use in DC link voltage of 848 V DC, which means it can be utilized for high voltage applications.

The first step in installing and configuring most devices is the use of the TwinCAT 3 Drive Manager 2, which provides a convenient interface for the configuration of the module. At the same time, it is possible to use the TwinCAT 3 Safety Editor TE9000 and TwinSAFE Loader/User TE9200 in order to carry out all projects that are safety relevant. In terms of physical dimensions, the AX8810 measures height 230 mm, depth 192 mm and width 60 mm which is small enough to be integrated in the present systems. Since it has an IP20 protection class, it is suitable for use in general industrial conditions within a temperature range of 0 to 40oC; it can go up to 50oC provided power is reduced.

Ambient Temperature (operation)
0…+40°C, up to +55°C with power reduction
Approvals/markings
CE, cULus, EAC
CE
Approved
Connection Type
screw terminal
Cooling
natural convection
Dc Link Voltage
max. 848 V DC
Depth Without Connectors
192 mm
Height Without Connectors
230 mm
Housing Protection Rating
IP20
Installation Altitude
max. 1000 m above sea level
Life Expectancy
40,000 h at 40 °C
Maximum Altitude (operation)
< 2000 m
Protection Against Shock
II
Weight
1 kg
Width
60 mm
Symptom / LED or drive alarm Likely root cause Corrective Action
PWR LED dark; no start-up 24 V DC supply absent or wired to the wrong pins Measure supply, check cabinet fuse and X01 pin-out
PWR/⚡ symbol flashes red fast DC-link is > 48 V while an error is pending (over-voltage during braking)  Wait for voltage to drop; lengthen decel ramps or add AX8820 regen unit
PWR/⚡ symbol flashes red slow DC-link still charged (> 48 V) after mains off; bleed time too long  Verify brake-chopper path, connect external resistor if required
Drives trip to DC-bus over-voltage (F8xx) when axes brake hard AX8810 fully charged; not enough buffer or regen capability Add a second AX8810 or fit an AX8820, soften braking ramps
Repeated under-voltage trips when enabling drives AX8810 not seen in the DC-link (link cable or fuse open) Inspect AX-Bridge bars, measure capacitance via scope, replace blown fuse
DC-link fails to charge on cold start; supply modules show “Capacitance exceeded” Total µF in link is above power-supply limit  Remove surplus AX8810/axis modules or upgrade to AX8640/AX8600
AX8810 runs hot (> 55 °C ambient) Cabinet temperature too high; convection blocked Improve ventilation, leave 25 mm clearance top/bottom, derate per manual 
Audible hum / bulging housing after years of operation Electrolytic capacitors aged Schedule replacement module; verify ripple current against drive duty
Ground-fault test on DC-link fails Insulation breakdown inside module or wiring Megger cables, isolate AX8810; replace if leakage > 5 MΩ
AX8810 not recognised by TwinCAT diagnostics Device-ID jumper or EtherCAT address unset Re-seat AX-Bridge ID jumpers; cycle power and rescan bus
Model Function Key rating Module width Typical role
AX8810-0000-0000 Capacitor buffer 1 755 µF, 0…848 V DC  60 mm  Stores brake energy to cut peak mains load
AX8820-0070-0000 Universal regenerative unit 7 kW sinusoidal energy recovery; 0…848 V DC  90 mm  Feeds surplus energy back to the grid
AX8620-0000-0000 Power-supply module 20 A DC link; 200…480 V AC in; 0…848 V DC out  60 mm  Base supply for small/medium AX8000 stacks
AX8640-0000-0000 Power-supply module 40 A DC link; 3-ph 200…480 V AC in; 0…848 V DC out  90 mm  Larger stacks or high-inertia machines
AX8600-0000-0000 DC power-supply module 50 A DC link; 24…680 V DC fed  60 mm  Starts a second AX8000 row when cabinet width is full
AX8831-0000-0000 AMP8000 coupling module 20 A DC link, 1-channel; up to 848 V DC  60 mm  Connects distributed servo drives to the AX8000 DC bus
Beckhoff code Meaning / typical trigger
FD4B – DC-link undervoltage Bus < approx. 560 V DC (mains dip, excessive inrush)
FD4C – DC-link overvoltage Regen energy pushes bus > 848 V DC (hard decel, regen disabled)
FD4A – IGBT temp-sensor error Drive’s power-stage temperature feedback implausible (often after sustained high ripple current in capacitors)
FCD3 – Overspeed detected Axis accelerates uncontrollably after DC-link surge
F340 – Position-offset invalid Power loss or brown-out corrupted encoder offset (common after undervoltage)
6180 – Internal software error A Fatal firmware trap, sometimes triggered by repeated bus faults
6181 – Internal software error B See above; second category
6183 – FPU exception Arithmetic overflow (e.g., extreme DC-link ripple values)
6190 – Init-timeout Start-up aborted because bus never reached nominal voltage
D102 – Drive in safe state TwinSAFE card latched after repeated power or bus errors

Frequently Asked Questions about AX8810-0000-0000:

Q: What is the maximum DC link voltage for the AX8810-0000-0000 module?

A: The maximum DC link voltage for the AX8810-0000-0000 module is 848 V DC.

Q: What is the operational ambient temperature range for the AX8810-0000-0000 module?

A: The operational ambient temperature range for the AX8810-0000-0000 module is 0 to +40 °C, with an extended range up to +55 °C when power reduction is applied.

Q: What approvals and markings does the AX8810-0000-0000 module have?

A: The AX8810-0000-0000 module is marked with CE, cULus, and EAC approvals.

Q: What are the dimensions of the AX8810-0000-0000 module without connectors?

A: The dimensions of the AX8810-0000-0000 module without connectors are: Height: 230 mm, Depth: 192 mm, and Width: 60 mm.

Q: Is the AX8810-0000-0000 module EAC approved?

A: Yes, the AX8810-0000-0000 module is EAC approved.


Internal Product Review

  • ‘‘The utmost DC connection voltage of the AX8810-0000-0000 servo drive is 848 V DC. It is a component of Beckhoff's AX Digital Servo Drive Series and is equipped with a natural convection cooling system and an enclosure protection rating of IP20. The transmission is exceedingly lightweight, weighing only 1 kg.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo