The Vickers EEA-PAM-581-A-32 is part of the EEA-PAM Power Amplifiers series and has a nominal supply voltage of 24 VDC with an input power of 50 watts. This amplifier features a DIN 41612 F48 Male connector interface and provides a reference voltage output of ±10 V at a maximum of 5 mA. The card measures 128.4 mm in height, 100 mm in width, and 175.24 mm in depth.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The EEA-PAM-581-A-32 is a plug-in power amplifier card produced by Vickers within the EEA-PAM Power Amplifiers series. Installed in a DIN 41612 backplane, the card conditions command signals and supplies drive current for electro-hydraulic proportional valves used in motion and pressure control loops on industrial machinery.

The module operates from a nominal bus of 24 VDC and draws up to 50 W, a level sized to energize the onboard reference generators, output stages, and feedback circuitry. A voltage input path presents 47 kΩ of impedance so that external controllers can deliver command signals without significant loading, while the current input path is fixed at 100 Ω to support standard 4-20 mA sources. Internally, the analog ramp generator can slew the output in as little as 50 ms, allowing quick yet controlled spool movement in the associated valve. Digital command lines are isolated at 22 kΩ, and monitor jacks offer 10 kΩ of impedance to minimize probe influence during diagnostics. Full-stroke feedback is available as ±10 V for direct observation of actuator position, and the reference network maintains ±1 % accuracy to keep closed-loop offsets small.

The card furnishes a regulated auxiliary rail of ±15 V, 50 mA Max for external signal conditioning, and an undervoltage circuit forces shutdown when the supply falls below <18 VDC to prevent erratic valve behavior. Physical depth is limited to 175.24 mm, while the 128.4 mm height and 100 mm width allow dense packing in standard 19-inch sub-racks. A separate reference output of ±10 V, 5 mA Max is provided for remote set-point generation or calibration tasks. Together, these electrical, protective, and mechanical characteristics support consistent valve actuation across a broad range of hydraulic automation platforms.

Amplifier Input Current at 0V Command Signal
1.7 A
Amplifier Shut-down Voltage
<18 VDC
Card Depth
175.24 mm
Card Height
128.4 mm
Card Width
100 mm
Command Signal Monitor Point Output
10 kohms short-circuit protected
Connector Interface
DIN 41612 F48 Male
Control Supply Output
±15 V, 50 mA Max
Current Input Impedance
100 Ω
Digital Input Impedance
22 kΩ
Input Power
50 W
Max. Solenoid Current
3.2 A
Minimum Ramp Time
50 ms
Monitor Point Impedance
10 kΩ
Nominal Power Supply
24 V DC
Nominal Supply Voltage
24 VDC
Output Monitor Voltage Full Stroke
±10 V
Overload Detection
Automatic reset
Protection
Reverse-polarity
Ramp-active Indicator Output
10 kohms
Ramps Input
22 kohms
Reference Voltage Accuracy
±1%
Reference Voltage Output
±10 V, 5 mA Max
Voltage Input Impedance
47 kΩ
Weight
330 g
  • EEA PAM 581 A 32
  • EEA-PAM-58l-A-32
  • EEAPAM581A32
  • eea-pam-581-a-32
  • eeapam581a32
  • EEA-PAM-S81-A-32
  • EEA-PAM-5B1-A-32
  • EEA-PAM-58I-A-32
  • EEA-PAM-581-A-3Z
  • EEA-PAM-SBI-A-3Z
  • EEAPAM-581-A-32
  • EEA-PAM581-A-32
  • EEAPAM581-A-32
  • EEA-PAM-581A-32
  • EEAPAM-581A-32
  • EEA-PAM581A-32
  • EEAPAM581A-32
  • EEA-PAM-581-A32
  • EEAPAM-581-A32
  • EEA-PAM581-A32
  • EEAPAM581-A32
  • EEA-PAM-581A32
Symptom / LED Indication Likely Cause Quick Troubleshooting Step
24 V LED off Card not powered (supply < 20 V DC, blown fuse, reversed polarity) Measure cabinet PSU, replace fuse, correct polarity then repower card.
15 V LED off while 24 V LED is on On-board ±15 V logic rail missing (regulator fault) Check ±15 V at test-jack z22 / b22; if 0 V replace regulator or card.
Enable LED dark although PLC outputs > +10 V to pin z24 Enable line actually < +6 V (broken PLC output / field wiring) Trace/repair line to z24, restore ≥ +10 V, reseat card to reset latch.
Overload LED lit (red) Solenoid current > 2.5 A (shorted coil or wrong valve) Measure coil Ω, inspect cable for shorts, fit correct coil; LED clears automatically.
LVDT 1 Fail LED on First feedback transducer open-circuit / out-of-range Verify ±15 V sensor supply, repair 6-pin cable on pins b14/z22/b16, re-zero loop.
LVDT 2 Fail LED on Second feedback channel fault (double-feedback amplifier) Repeat Step 5 for pins z14/z22/z16; both fail LEDs must be OFF before operation.
Watch-dog LED flashing Internal micro-controller or noisy 24 V supply Power-cycle card; if fault recurs, add 24 V filtering or replace card.
Ramp pots have no effect / valve jerks Quadrant-ramp bypass link b12–b20 left closed Remove jumper or route it through a remote switch to re-enable 4-quadrant ramps.
Command signal present but no valve motion Set-minimum or Gain pots fully CCW (zero output) Turn pots CW until monitor jack MP1 ≈ ±0.5 V; verify valve stroke.
Card drops out < 19 V or at > 50 °C Low-voltage or thermal protection tripped Upgrade PSU (≥ 50 W) / improve cabinet cooling; allow board to cool < 45 °C, then restart.
Model Intended Valve Family Command Inputs Ramp Generator Diagnostics / LEDs Max Coil I (A)
EEA-PAM-581-A-32 KHDG5V-5/7/8, double-feedback servo ±10 V + ±15 V ref Four-quadrant (acc/dec each dir.) 24 V, 15 V, Enable, Overload, 2× LVDT Fail, Watch-dog 2.5
EEA-PAM-571-A-32 KFDG5V high-dynamic servo ±10 V + ±15 V ref Four-quadrant LVDT Fail, Overload, Watch-dog 2.5
EEA-PAM-553-D-33 KSDG4V-3 servo spools ±10 V + sensor ref Quad-ramp 24 V, 15 V, Enable, Overload, Dual LVDT Fail 2
EEA-PAM-561-A-32 KDG5V-5/7 spools (single LVDT) ±10 V Dual independent ↑/↓ 24 V, 15 V, Enable, Overload, LVDT Fail 1.8
EEA-PAM-535-D-33 KF*G4V-5 proportional flow 0–10 V × 5 | 0–20 mA × 1 Single adj. (20 ms–3 s) 24 V, 15 V, Enable, Overload 1.6
EEA-PAM-525-A-32 KDG4V-5 high-flow directional 0–10 V × 5 | 0–20 mA × 1 Single adj. 24 V, 15 V, Enable, Overload 1.6
LED / Condition Likely meaning
24 V LED off No or low 24 V DC (< 20 V)
15 V LED off (24 V LED on) Internal ±15 V logic rail missing
Enable LED dark (PLC sends > 10 V to z24) Enable line actually < 6 V (open wire or PLC output fault)
Overload LED lit Coil current > 2.5 A (shorted coil / wrong valve)
LVDT 1 Fail LED Feedback transducer 1 open-circuit / out of range
LVDT 2 Fail LED Fault on second LVDT channel
Watch-dog LED flashing Micro-controller reset caused by noise or firmware fault
Ramp pots have no effect Quadrant-ramp bypass link b12–b20 left closed
Command present but no valve motion Set-minimum or Gain pots turned fully CCW
Card drops out when 24 V < 19 V or temp > 50 °C Low-voltage or over-temperature protection active

Frequently Asked Questions about EEA-PAM-581-A-32:

Q: What is the required supply voltage for the EEA-PAM-581-A-32 power amplifier?

A: The EEA-PAM-581-A-32 operates with a nominal supply voltage of 24 VDC.

Q: What connector interface does the EEA-PAM-581-A-32 power amplifier use?

A: The connector interface for this amplifier is a DIN 41612 F48 Male connector.

Q: What is the input power specification of the EEA-PAM-581-A-32 amplifier?

A: The input power rating for the EEA-PAM-581-A-32 is 50 W.

Q: What is the reference voltage output capability of the EEA-PAM-581-A-32 amplifier?

A: This amplifier provides a reference voltage output of ±10 V with a maximum current of 5 mA.

Q: What is the minimum ramp time setting for the EEA-PAM-581-A-32 power amplifier?

A: The minimum ramp time specified for the EEA-PAM-581-A-32 is 50 ms.


Internal Product Review

  • ‘‘The EEA-PAM-581-A-32 from Vickers is a power amplifier designed for precise control with a ±10 V reference voltage output and 1% accuracy. Its 24 VDC nominal supply voltage and 50 W input power ensure consistent performance in demanding hydraulic applications. The model stands out for its reliable signal processing and stable operation.’’