4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

KDA3.2-100-3-A00 Bosch Rexroth Indramat

Ask for Availability
Current Response Time 6 min 36 sec
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The KDA3.2-100-3-A00 is a Bosch Rexroth Indramat spindle drive with a well-executed industrial design. Forced cooling and a 300 V DC bus support stable performance under demanding spindle duty. Vertical mounting and IP10 protection make the unit a strong choice for structured cabinet installations.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA3.2-100-3-A00 spindle drive is produced by Bosch Rexroth Indramat as part of the KDA Spindle Drives series. As a closed-loop power module, it supplies regulated current to high-speed motorized spindles used in machine tools and other metal-cutting equipment. It converts low-level command signals from a CNC controller into controlled armature power for accurate speed and torque regulation. The unit is intended for applications where stable spindle performance is required during cutting, drilling, and similar continuous-duty processes.

It operates from a DC bus of 300 V, which is typically supplied by a shared power unit and sets the available voltage for spindle acceleration. The drive can deliver a rated armature current of 100 A and a continuous output current of 70 A, indicating its overload capacity and sustained operating level. Internal power devices use forced cooling, so an external blower is required to keep semiconductor temperatures within the permitted range during demanding duty cycles. The housing has an IP10 protection rating, which means it has open ventilation paths and should be installed inside a filtered control cabinet. Measurement circuits draw 160 mA from the ±15 V supply for current and voltage monitoring, and the second encoder port is omitted when only a primary feedback channel is needed.

The permitted ambient operating range is 5 to 45 °C, which suits typical factory conditions. Installation is allowed at elevations up to 1000 m, where air-cooling performance remains suitable for normal operation. The unit must be mounted in a vertical orientation so airflow passes correctly across the heat sink. Control electronics require 1.4 A from the +24 V logic supply, leaving room on standard cabinet control power circuits. Because the enclosure is openly ventilated, cabinet layout should provide clean airflow and adequate spacing around the drive.

Ambient Temp Range
5 to 45 Degrees Celsius
Continuous Current
70 A
Control Load Current (+24 V)
1.4 A
Cooling Mode
Forced Cooling
DC Bus Voltage
300 V
Max Installation Elevation
1000M above sea level
Measuring Voltage Current (±15 V)
160 mA
Mounting Orientation
Vertical
Product Type
Spindle Drive
Protection Category
IP10
Rated Current
100 A
Second Encoder Input
Does not feature additional input

Frequently Asked Questions about KDA3.2-100-3-A00:

Q: What is the rated current of the KDA3.2-100-3-A00 spindle drive?

A: The KDA3.2-100-3-A00 spindle drive has a rated current of 100 A, supporting demanding spindle applications.

Q: What cooling method does the KDA3.2-100-3-A00 spindle drive utilize?

A: Forced cooling is used for the KDA3.2-100-3-A00, requiring airflow for heat dissipation.

Q: What is the protection category of the KDA3.2-100-3-A00?

A: The protection category for this drive is IP10, providing basic protection against solid objects.

Q: What is the allowable ambient temperature range for the KDA3.2-100-3-A00?

A: This model can operate in ambient temperatures between 5 to 45 degrees Celsius.

Q: Does the KDA3.2-100-3-A00 spindle drive support a second encoder input?

A: The KDA3.2-100-3-A00 does not include a second encoder input, so only primary encoder feedback is supported.

Fault / LED code (F-class) Likely cause Quick corrective action
F218 – heatsink over-temperature Internal blower clogged or cabinet > 45 °C Clean / replace fan, add airflow, wait to cool, then Reset Class 1 Diagnostics. 
F219 – motor over-temperature 2AD / 1MB thermistor ≥ 155 °C Lower load, check external motor fan, allow full cool-down, re-enable. 
F220 – bleeder resistor overheating Excess regenerative energy during braking Lengthen decel ramps or add / up-size external brake resistor; clear when cool. 
F226 – DC-bus undervoltage KDV supply brown-out or loose bus bars Restore mains & bus ≥ 300 V, retighten connectors, then reset drive. 
F228 – following-error too large Spindle can’t track speed demand Lower accel/vel ramps, inspect mechanics for drag, retune velocity loop.
F229 – encoder 1 quadrant error Resolver / encoder signal faulty Reseat shielded cable, route away from power leads, swap encoder if fault repeats. 
F230 – encoder frequency too high Spindle speed exceeds interface limit Limit max rpm or fit lower-PPR encoder; clear and restart.
F233 – +24 V control-supply error Aux 24 V lost (often via E-Stop loop) Restore 24 V rail, verify E-Stop chain, Reset Class 1.
F234 – emergency-stop active E-Stop contact open Locate & reset E-Stop, restore 24 V, then power-cycle or reset.
No LEDs, blower running Drive in thermal / hardware self-protect Measure 300 V bus & 24 V, test fan supply (220 VAC); if self-test fails, replace drive. 
Model Firmware design Rated current (A) DC-bus (V) Cooling Notes
KDA 3.2-100-3-A00-W1  3.2 100 300 Heatsink blower Analog ±10 V speed cmd. 
KDA 3.2-150-3-A00-W1 3.2 150 300 Blower Same design, higher current for large 1 MB spindles. 
KDA 3.2-050-3-A00-W1 3.2 50 300 Blower Lighter spindle axes, drop-in lower-current swap. 
KDA 3.3-100-3-A00-W1 3.3 100 300 Blower Newer 3.3 firmware, extended diagnostics. 
KDA 3.1-100-3-A00-W1 3.1 100 300 Blower Earlier 3.1 design; core specs identical. 
KDA 2.1-050-3-A00-W1 2.1 50 300 Blower Oldest 2.1 series, still bus-compatible. 
Error code What it means
F218 Heatsink over-temperature shutdown
F219 Motor over-temperature (thermistor ≈ 155 °C)
F220 Bleeder-resistor over-temperature
F226 DC-bus undervoltage while enabled
F228 Excessive deviation (following-error)
F229 Encoder 1 failure – quadrant error
F230 Max. signal frequency of encoder 1 exceeded
F233 External power-supply error (+24 V / ±15 V control rail)
F234 Emergency-Stop activated (+24 V to E-Stop input lost)
F236 Excessive position-feedback difference (encoders 1 & 2)
Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo