HMV02.1R-W0015-A-07-NNNN

MPN: R911309080

No Tariffs On US Orders
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
    In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The HMV02.1R-W0015-A-07-NNNN Supply Unit is manufactured by Rexroth Indramat Bosch. This unit has a Regenerative power supply and an Internal Air Blower cooling mode. This HMV Supply Unit has a rated output of 15 and a nominal voltage of DC 700V.

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HMV02.1R-W0015-A-07-NNNN is one of the most technically advanced and ergonomically designed HMV Series Power Supply Unit created by Indramat Bosch Rexroth. With a Rated Regenerative Output power of 15 kW, it has proven to be a cost-effective and most efficient range of smart energy power supply modules.

The HMV02.1R-W0015-A-07-NNNN is one of the best products which has two line inputs using a nominal consumption of DC 700 volts and gives an impressive output of 15 kilowatts. It also features some of the most innovative solutions to increase efficiency by creating the optimum operating parameters. For example, it has an integrated source of cooling which is provided by using internal strategically placed blowers units.

Rexroth Bosch Indramat, which ensures the best of quality and safety standards, had designed it as per Protection Mode IP 20 which ensures higher reliability.

Its energy consumption is well within limits and during maximum braking is just 40 kW. The braking power in the normal mode of operation is just 0.3 in kW, while the maximum braking power is barely 33 kW. The current is usage is 1.1 A.

Some other specifications worth mentioning are-

DC-bus capacity - 700 Μf

Maximum output power – 25 kW

Power utilization - 27 W

Continuous input current - 23 A

These figures are for normal conditions of operation. If, however, the operation is under different conditions, the performance is marginally different, but within permissible limits. This is more so in case of dependent factors related to optimum capacity utilization such as the continuous current, rated breaking power, DC bus output, etc. E.g. the output current of HMV02.1R-W0015-A-07-NNNN shows a marginally lower reading at higher switching frequencies. This product is available from Wake Industrial with a one-year warranty period.

Continuous Input Current
23 A
Cooling Mode
Internal Air Blower
Maximum Braking
40 kW
Maximum Elevation Height
1000 MSL
Maximum Output Power
25 kW
Product Type
Power Supply Unit
Protection Rating
IP20
Rated Output
15 kW
Reverse Polarity Protection
Available
Series
HMV Series
  • HMV02 1R W0015 A 07 NNNN
  • HMV021RW0015A07NNNN
  • hmv02.1r-w0015-a-07-nnnn
  • HMV2.1R-W0015-A-07-NNNN
Fault / Message What it means Corrective action
F 2003 – supply over-temperature The HMV heatsink is above the shutdown limit. Check that the cabinet is below 45 °C, clean / replace the internal blower and filters, and verify the minimum clearance above and below the unit. 
F 2004 – mains undervoltage Input drops > 10 % below 380 V AC. Measure the three-phase feed, inspect upstream contactors or fuses, correct utility brown-outs. 
F 2005 – mains overvoltage Line exceeds +10 % of 480 V AC. Verify transformer taps, remove transient-generating loads, or add a line reactor. 
F 2026 – DC-bus undervoltage DC link < 500 V during run. Re-engage the mains, lighten instantaneous load, or check pre-charge circuitry. 
F 2032 – earth-leak/ground fault Leakage detected between DC bus and PE. Isolate drives one-by-one to find the faulty cable or motor; megger suspect wiring. 
F 2036 – regen not ready Line-side active front end cannot return energy. Inspect mains contactor X31, DC-bus choke, and parameter P-0-4016; replace IGBT module if faulty. 
F 2038 – brake-chopper overload Internal bleeder hit 100 % duty. Lengthen deceleration ramps, fit an external resistor, or use a larger HMV size. 
F 2084 – gate-drive fault / over-current Short on the IGBT bridge or DC-bus. Check motor cables for shorts, inspect IGBT gate board; replace power module if error recurs. 
F 2180 – temperature warning Early warning 15 K below F 2003 trip. Improve airflow before the unit shuts down; verify that switch-cabinet fans run. 
F 2410 – 24 V control-voltage fault Auxiliary rail out of tolerance or overloaded. Measure X2-24 V, disconnect external loads, and test the cabinet PSU. 
Full part number Continuous output power Regenerative? Cooling method Input voltage Typical use-case
HMV02.1R-W0015-A-07-NNNN 15 kW ✔ (“R” front-end) Internal blower, IP20 3 × AC 380-480 V Small multi-axis cells or retrofit drives
HMV02.1R-W0045-A-07-NNNN 45 kW Internal blower 3 × AC 380-480 V Medium-size machining centres
HMV02.1R-W0075-A-07-NNNN 75 kW Internal blower 3 × AC 380-480 V Large packaging or robot lines
HMV02.1R-F0150-A-07-NNNN 150 kW ✔ (active front-end, higher I-rating) Forced-air (dual fans) 3 × AC 380-480 V High-inertia presses, test stands
HMV02.1E-F0025-A-07-NNBN 25 kW ✖ (“E” = diode feed, non-regen) Internal blower 3 × AC 380-480 V Economical feed supply for axes with low braking energy
HMV01.1R-W0045-A-07-NNNN 45 kW Internal blower 3 × AC 380-480 V Earlier hardware (HMV 01) for legacy IndraDrive M cabinets
Code Meaning / Condition
F2003 Supply over-temperature shutdown
F2004 Mains undervoltage
F2005 Mains overvoltage
F2026 DC-bus undervoltage during run
F2032 Earth-fault / leakage detected
F2036 Regeneration not ready (AFE disabled)
F2038 Brake-chopper overload
F218 Drive amplifier over-temperature
F219 Motor over-temperature
F2840 Emergency supply shutdown

Frequently Asked Questions about HMV02.1R-W0015-A-07-NNNN:

Q: What are the input specifications for the HMV02.1R-W0015-A-07-NNNN?

A: The HMV02.1R-W0015-A-07-NNNN has two line inputs with a nominal consumption of DC 700 volts. This allows for efficient energy usage while maintaining the device's high performance standards.

Q: What is the output capacity of the HMV02.1R-W0015-A-07-NNNN?

A: This product delivers an impressive output of 15 kilowatts. It's designed to handle substantial power requirements, making it suitable for demanding industrial environments. The high output capacity ensures consistent performance under varying load conditions.

Q: How does the HMV02.1R-W0015-A-07-NNNN enhance operational efficiency?

A: It features innovative solutions like optimum operating parameters and an integrated cooling system with strategically placed internal blowers. These features not only increase efficiency but also ensure the longevity of the unit by maintaining optimal operating temperatures.

Q: What safety and quality standards does the HMV02.1R-W0015-A-07-NNNN adhere to?

A: Designed by Rexroth Bosch Indramat, it meets the high-quality and safety standards, including the protection class of IP 20. This ensures higher reliability and safety in various industrial settings, conforming to rigorous industry standards.

Q: What are the braking power specifications of the HMV02.1R-W0015-A-07-NNNN?

A: In normal operation, the braking power is just 0.3 kW, while the maximum braking power is 33 kW. This range allows for efficient energy dissipation and control, especially in dynamic industrial processes.