Product Description:

Rexroth Bosch's 2AD132C-B35OA1-BS03-B2N1 motor has a flange and foot mounting (B35), which is beneficial in many industrial applications to mount motors in different orientations. This flange mounting style offers a secure support for the motor through a flange, while foot mounting enables the motor to be easily screwed to equipment using foot as additional support. The assembly of the motor in a system ensures that the motor does not move from its position because undesired shaking causes vibrations and wear. It also makes maintenance easier especially when there is a need to remove or replace the motor. These dual mounting styles are suitable for machines requiring a rigid, safe and vibration-proof motor mounting area.

Top (O) power connection means that the connector will be at the top of the motor. This feature is very useful during the installation of the motor as power cables are easier to attach and fix. It organizes the cables in a proper manner, which minimizes the possibility of getting damaged or in contact with other parts of the system. This makes it easier to organize cables, especially in restricted areas to avoid entanglement or misalignment. It also offers a better layout of the motor connections which is more critically needed for systems where cabling has to be well managed and accessible.

Features such as flange and foot mounting along with the top power connection, make the motor easy to install, highly durable and reliable. This combination is critical, especially in industries requiring safe, and efficient motors with less frequent servicing needs. It provides effective functioning, correct mounting, and extended durability in addition to safety and easy maintenance. This motor is ideal and stable enough to deliver optimal performance in continuous operations.

Bearings
Standard
Cooling mode
Axial fan
Driven shaft
Balanced with entire key
Length
C
Mounting
Flange and Foot type
Output direction of power connection
to side A
Position of power connection
Top
Size
132
Vibration severity grade
R
Winding code
BS
  • 2AD132C B35OA1 BS03 B2N1
  • 2AD132CB35OA1BS03B2N1
  • 2AD132C-B350A1-BS03-B2N1
  • 2AD132C-B35OA1-BSO3-B2N1
  • 2AD132C-835OA1-8S03-82N1
  • 2AD132C-835OA1-8SO3-82N1
  • 2AD132CB350A1BS03B2N1
  • 2AD132CB35OA1BSO3B2N1
Error Code Fault / Alarm Name Typical Cause(s) Recommended Corrective Action
F208 Motor over-temperature Cooling fan failure, blocked airflow, ambient temp > 40 °C, sustained overload Verify motor fan operation and airflow paths, reduce load or duty cycle, let motor cool to < 60 °C before restart
F213 Motor over-current Rotor jam/over-load, shorted stator winding, incorrect current-limit parameters Remove mechanical binding, megger motor windings, re-enter rated current in drive parameters
F219 Feedback (encoder/resolver) fault Broken/loose feedback cable, shield not grounded, misaligned encoder Inspect feedback connector X4, check 5 V supply & differential signals, re-align or replace feedback device
F210 Excessive speed deviation PID gain set too low, loose coupling, erratic line power Auto-tune speed loop, verify mechanical couplings, stabilise mains supply
F220 Phase loss / wiring error Open or swapped power leads U/V/W, burned terminal Torque-check motor terminals, continuity-test cable, correct phase order
F203 DC-bus undervoltage Mains drop-out, undersized transformer, blown fuses in L1-L3 Measure line supply (nom. 3 × 400 V AC), inspect upstream fuses/contactor, size transformer per 2AD132C ratings
F201 Overspeed condition Incorrect speed command, feedback ratio wrong, motor run-away on load loss Confirm velocity limits in drive, verify encoder pulses/rev, inspect mechanical drive-train
F228 Inverter output-stage fault Shorted IGBT, grounded motor cable, contaminated heat-sink Isolate motor leads, insulation-test cable, clean heat-sink, replace power module if fault repeats
F234 Resolver/encoder battery low (Σ-ABS) 3 V lithium backup cell at end-of-life Replace battery within 24 h to prevent loss of multiturn position data, then clear fault
F280 Excessive vibration / bearing wear alarm Worn bearings (> 50 000 h), shaft imbalance, improper mounting Vibration-analyze (ISO 10816), replace bearings, laser-align motor-to-load, add resilient mounts
Part Number Length Code Rated Power (kW) Rated Torque (Nm) Rated Speed (rpm)
2AD132C-B35OA1-BS03-B2N1 C 15 kW 96 Nm 1500 rpm
2AD132C-B05OA1-BS03-B2N1 C 15 kW 96 Nm 1500 rpm
2AD132C-B35RA1-BS11 C 13.2 kW 115 Nm 1100 rpm
2AD132B-B35OA1-BS03-B2N1 B 7.5 kW 48 Nm 1500 rpm
2AD132D-B35OB1-AS03-A2N2 D 22 kW 140 Nm 1500 rpm
2AD160C-B35OA1-BS03-B2N1 C 37 kW 236 Nm 1500 rpm
Error Code Typical Meaning 
F208 Motor over-temperature detected
F213 Motor over-current (possible rotor jam or winding short)
F219 Feedback fault (encoder/resolver signal error)
F210 Excessive speed deviation / control loop instability
F220 Phase loss or power-lead wiring error
F203 DC-bus undervoltage (mains dropout or fuse open)
F201 Overspeed condition (command or feedback mismatch)
F228 Inverter output-stage fault (IGBT or cable short)
F234 Feedback battery low (multiturn absolute encoder)
F280 Excessive vibration / bearing-wear alarm

Frequently Asked Questions about 2AD132C-B35OA1-BS03-B2N1:

Q: Can an additional position encoder be attached with this model?

A: Yes, it is possible to attach an additional encoder to the B side of the motor with the help of a shaft extension. This setting requires a radial blower for faster cooling.

Q: What are the ideal operating conditions for this model?

A: The 2AD132C-B35OA1-BS03-B2N1 can be operated in areas where the ambient air temperatures are between 0 degrees and 40 degrees celsius. In addition, the maximum allowed installation height is a 1000 meters above sea level.

Q: Which type of shaft connection is the most suitable for torque transmission in a constant direction?

A: For applications requiring torque transmission in a constant direction, the output shaft with a key configuration is the most suitable choice.

Q: What are the primary applications of the 2AD132C-B35OA1-BS03-B2N1?

A: The 2AD132C-B35OA1-BS03-B2N1 can be used as a main spindle and a servo drive. The motor is suitable for automating packaging machines, woodworking machines, printing machines, and other similar equipment.

Q: What are the main advantages of this model?

A: The 2AD132C-B35OA1-BS03-B2N1's main advanatges are its high resolution feedback and its wide speed range at which it can transmit high torque.