4.95 based on 202 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

2AD132C-B05OL1-CS03-D2V1 Bosch Rexroth Indramat

MPN: R911267986

No Tariffs On US Orders
  • Rated 4.5 (46 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat 2AD132C-B05OL1-CS03-D2V1 is an AC induction motor from the 2AD 3-Phase Induction Motors series. It features heavy-duty bearings, high-resolution motor feedback, and an axial blower cooling system. This motor utilizes flange mounting and has a power connection at the top, directed to the left.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 2AD132C-B05OL1-CS03-D2V1 is an AC induction motor manufactured by Bosch Rexroth Indramat for the 2AD 3-Phase Induction Motors series. Designed for plant-wide automation, the unit delivers continuous rotary motion to pumps, gantry axes, or spindle assemblies when it is operated from a matched frequency inverter. It provides repeatable speed and torque in a compact form, making it suitable for material-handling cells, packaging machines, and general factory equipment.

The motor has a size code of 132 and a length code of C, giving it a frame diameter and axial stack that balance torque density with installation space. Heavy-duty bearings support the shaft under belt pull or overhung loads, which helps the motor withstand demanding duty cycles. Standard flange mounting positions the stator face directly against gearboxes or machine plates for straightforward alignment. The output uses a full-key shaft with a shaft seal to transmit torque while helping keep lubricant inside the machine envelope, and the non-drive side is supplied without a shaft end. The CS winding code indicates the electrical values expected by the connected inverter.

Thermal management relies on an integrated axial blower that forces airflow through internal ducts and across external fins, keeping winding temperature within allowable limits during continuous duty. Precise speed regulation is enabled by high-resolution motor feedback, which provides accurate rotor position data for vector or servo control algorithms. The power terminal box is mounted on top of the housing with its cable outlet facing left, which simplifies cable routing in enclosed installations. Because the motor is supplied without a holding brake, position retention during shutdown must be provided by drive torque or an external clamp. Dynamic balance meets vibration grade R, which helps limit residual oscillation during operation.

Bearings
Heavy-duty
Brake
Without holding brake
Cooling Type
Axial Blower
Feedback Device
High-resolution motor feedback
Motor Length Code
C
Motor Size Code
132
Mounting
Flange mounting
Power Connection Direction
To Left
Power Connection Position
Top
Product Type
AC Induction Motor
Shaft End (Side B)
Without shaft end
Shaft Type
shaft seal, with balanced with entire key
Vibration Grade
R
Winding Code
CS
  • 2AD132C B05OL1 CS03 D2V1
  • 2AD132CB05OL1CS03D2V1
  • 2AD132C-B050L1-CS03-D2V1
  • 2AD132C-BO5OL1-CSO3-D2V1
  • 2AD132C-805OL1-CS03-D2V1
  • 2AD132C-8O5OL1-CSO3-D2V1
  • 2AD132CB050L1CS03D2V1
  • 2AD132CBO5OL1CSO3D2V1
Fault Code Error Description Likely Cause Recommended Fix
E2-51 Motor over-temperature warning Restrictive or failed blower; continuous overload / high ambient temps Inspect/clean/replace blower, improve ventilation, reduce load, allow cool-down
F2-19 Motor over-temperature shutdown Severe thermal rise—thermistor trips after warning threshold  Same as row 1; verify thermistor integrity before restart
F2-29 Motor encoder failure (Quadrant error) Damaged/loose encoder cable, connector contamination, encoder misalignment Reseat connectors, check shielding, scope encoder signals, realign or replace encoder
F8-60 Over-current: short in power stage Phase-to-phase or phase-to-ground short in stator, wiring, or drive IGBTs Isolate motor; meg-ohm and resistance test; inspect drive’s power module before re-enable
F2-26 DC-bus under-voltage Mains sag, blown fuses, failing supply module, or loose power wiring Measure incoming VAC & DC-bus; correct supply, tighten terminals, replace supply if faulty
F2-83 Line over-voltage Excess regeneration during rapid decel or oversized inertia Verify braking resistor & wiring, lengthen decel ramp, add regen module if needed
F8-20 Bleeder (braking-resistor) overload Continuous or high-peak regen causing resistor overheat Check resistor rating/ventilation, add larger bleeder, soften decel, allow cool-down
F2-68 Brake error Holding-brake coil open, insufficient release voltage, mechanical stiction Measure brake-coil voltage, inspect wiring, adjust spring torque, clean brake surfaces
F2-22 Drive heatsink-temperature monitor defective Actual drive overheat or faulty sensor on heatsink Improve cabinet airflow, verify fans, replace temp sensor/drive if sensor is faulty
E2-25 Over-voltage error (drive or motor) DC-bus exceeds limit—regeneration, supply spikes, or incorrect settings Inspect mains, check regen path, tune decel/accel ramps, confirm parameter limits
Part Number Frame Ø (mm) Length Code Winding Code Factory Cooling Nominal Power (kW) Nominal Torque (Nm)
2AD132C-B05OL1-CS03-D2V1 132 C CS Axial blower (B05) 15 kW 96 Nm
2AD100C-B05OB1-AS03-D2N1 100 C AS Axial blower 5.5 kW 35 Nm
2AD104C-B35OB1-CS06-D2N1 104 C CS Axial blower 7.5 kW 48 Nm
2AD132B-B35OB1-BS03-D2V1 132 B BS Axial blower 10 kW 64 Nm
2AD132D-B05OB1-BD03/S015 132 D BD Axial blower 22 kW 140 Nm
2AD160C-B05OB1-BS03-A2N1 160 C BS Radial blower 37 kW 236 Nm
Code Description (short)
E251 Motor over-temperature warning
F218 Amplifier over-temperature shutdown
F219 Motor overload / thermal shutdown
F226 DC-bus undervoltage
F229 Quadrant (encoder) error
F268 Brake current out of range (brake error)
F2-20 Bleeder (braking resistor) over-temperature
F820 Bleeder resistor overload
F2-83 Line over-voltage
F383 Supply line-voltage fault (HVR/HVE modules)

Frequently Asked Questions about 2AD132C-B05OL1-CS03-D2V1:

Q: What type of bearings are used in the 2AD132C-B05OL1-CS03-D2V1 motor?

A: This motor uses heavy-duty bearings for improved durability under demanding conditions.

Q: What cooling method is utilized by the 2AD132C-B05OL1-CS03-D2V1 motor?

A: The 2AD132C-B05OL1-CS03-D2V1 features axial blower cooling for enhanced heat dissipation.

Q: What kind of feedback device is included with the 2AD132C-B05OL1-CS03-D2V1?

A: High-resolution motor feedback is integrated for precise position detection.

Q: What is the shaft configuration for the 2AD132C-B05OL1-CS03-D2V1 motor?

A: The shaft includes a seal and is balanced with the entire key for stable performance.

Q: Does the 2AD132C-B05OL1-CS03-D2V1 motor include a holding brake?

A: This motor does not come with a holding brake pre-installed.


Internal Product Review

  • ‘‘The 2AD132C-B05OL1-CS03-D2V1 is a Bosch Rexroth AC induction motor designed for flange mounting. Heavy-duty bearings and high-resolution motor feedback support smooth operation and accurate response in demanding drive systems. Axial blower cooling is a strong advantage for continuous industrial service.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo