SC104-036-T3
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Pacific Scientific SC104-036-T3 is a part of the SC100 Brushless Servo Controllers series, designed for vertical mounting and offering peak output power of 17 kW for 5 seconds. With an efficiency of over 95% at rated continuous power, it supports input voltage of 230 VAC and operates with three input phases.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
This SC104-036-T3 servo controller supplied by Pacific Scientific has five red diagnostic LEDs and two green diagnostic LEDs. The controller’s front panel is held in place by four nylon thumbscrews. This product’s control board can be removed when the front panel is detached. The device’s cooling slots and heatsink fins should be kept free of dust buildup. This unit’s cleaning is allowed with only suitable agents. Its repair must be undertaken by only authorized personnel. The controller incorporates time delay main input fuses.
This product is associated with a 036 customization code. The device’s DC bus voltage can be turned on and off. This unit controls the three-phase currents of its connected motor. Its base driver circuit offers voltage isolation between the output signals of its deadband circuit. The controller is safeguarded against damage because of abnormal operating conditions by internal protection circuits. This product is likely to encounter a high bus voltage because of a shunt regulator failure. The device supports brushless servomotors with Hall Effect systems for feedback. This unit encompasses protective override jumpers to override three protective circuits. Its velocity loop portrays an ultra-low drift.
The controller has an 800 Hz nominal current loop bandwidth. This product’s maximum installation altitude is 5000 ft. The device uses the TB3 screw terminal block for its power connections. This unit’s electronic components must be free of dirt and dust accumulation. Its storage temperature is -55 °C to 70 °C and is done horizontally. The servo controller needs to be protected against excessive shock or vibration at all times.
Frequently Asked Questions about SC104-036-T3:
Q: How is the heatsink temperature of the SC104-036-T3 controller monitored?
A: The heatsink temperature of the SC104-036-T3 controller is monitored using two positive temperature coefficient thermistors.
Q: Which protective features of the SC104-036-T3 controller can be overridden?
A: The I*t, Tach Fault, and Enable Lockout protective features of the SC104-036-T3 controller can be overridden.
Q: Where should the SC104-036-T3 controller be stored?
A: The SC104-036-T3 controller should be stored in a dry and clean place.
Q: What enclosure does the SC104-036-T3 controller fit in?
A: The SC104-036-T3 controller fits in a 16 x 12 x 10 in. Hoffman enclosure.
Q: How should the power and signal lines of the SC104-036-T3 controller be separated?
A: The power and signal lines of the SC104-036-T3 controller should be separated by at least 12 inches.