SC104-001-T1
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The SC104-001-T1 servo controller delivers a continuous output current of 20 amps, a peak output power of 17 kW, an efficiency exceeding 95%, and operates with an input voltage of 230 VAC. Part of the SC100 Brushless Servo Controllers series by Pacific Scientific, it features a switching frequency of 5 kHz and weighs 16 lbs.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
This SC104-001-T1 servo controller needs a ventilated cabinet for its installation. The controller has four slots for wall mounting. This product portrays a 55 W power dissipation at 25% of the rated continuous output power. The device’s control supply and input fuses can be accessed at its top. This unit’s housing has a nameplate attachment. It must be free of damage when its installation is done. The controller must have at least 4 mm of free space above and also below its housing in the cabinet.
This product’s handling and working are reserved for qualified individuals. The device’s mounting is done on four 5/16-inch slots on an eight-inch square. This unit is highlighted by an open-frame construction. Its adjustment during the setup process by removing the front panel. The controller comes with a five-position DIP switch that is used for selecting the functions of three input terminals. This product comprises two floating terminals in its fault relay contact. The device’s output phases must be properly phased with respect to the terminals of the related motor. This unit’s +BUS, REGEN, and RESISTOR terminals are used for applications where an external shunt regulator resistor is needed. Its power outputs may generate noise when the operation phase is on.
The servo controller supports use with a Tachsyn feedback transducer. This product’s operating mode can be selected using its eight plug jumpers. The device’s controller board has five user adjustments. This unit’s DS2, PWR LED has the top priority. Its motor fails to respond, although the controller is enabled in case of an open motor connection.
Frequently Asked Questions about SC104-001-T1:
Q: Why does the Enabled LED of the SC104-001-T1 controller not light up?
A: The Enabled LED of the SC104-001-T1 controller does not light up because the control board is defective.
Q: What is the tach gradient of the processor board of the SC104-001-T1 controller?
A: The tach gradient of the processor board of the SC104-001-T1 controller is 0.5 V/Krpm.
Q: What is the function of the process card of the SC104-001-T1 controller?
A: The process card of the SC104-001-T1 controller adds high-level motion control to the controller.
Q: How is the SC104-001-T1 servo controller configured?
A: The SC104-001-T1 servo controller is configured as a velocity control unit.
Q: When does the shunt regulator of the SC104-001-T1 controller operate in bus decay mode?
A: The shunt regulator of the SC104-001-T1 controller operates in bus decay mode if the Bus Enable signal is inactive and the DC bus is turned off.