S74802-PBF2-PM Kollmorgen
Wake Industrial LLC is not an authorized distributor of this product.
The Kollmorgen S74802-PBF2-PM is a servo drive from the S700 Servo Drives series. It features a rated input power of 35 kVA and operates with a voltage rating from 208 to 480 volts. The drive has a peak output current of 96 Arms and weighs 13 kilograms.
Internal Product Review
The S74802-PBF2-PM is a Kollmorgen S700 servo drive with 48 Arms rated current and 96 Arms peak output current. Dual channel STO and a 208...480V voltage rating give the drive excellent flexibility for secure integration in demanding motion systems. An 8 kHz switching frequency rounds out a very capable servo platform.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The S74802-PBF2-PM is a servo drive produced by Kollmorgen within the S700 Servo Drives series. As a closed-loop power stage, it interfaces between a three-phase mains supply and a synchronous or induction motor, modulating voltage and current so the motor follows motion commands issued by the machine controller. In automated assembly cells and processing lines, the drive supplies rapid acceleration, controlled deceleration, and functional safety for axes that demand precise positioning.
Electrically, the drive accepts a mains range of 208 to 480 V and can process up to 35 kVA of input power before derating. Under continuous operation, the output stage supplies 48 Arms, while transient moves such as indexing or emergency braking can draw a peak of 96 Arms. Power devices inside the S700 switch at 8 kHz, a carrier frequency that balances motor acoustic noise with semiconductor losses. Dual-channel STO circuitry allows torque to be removed without opening the main contactor, and a 5 V Posi/O signal level aligns the drive's I/O handshake with common PLC hardware. A dedicated fan-controller expansion card modulates blower speed to maintain component temperatures within the intended range, and the control section uses standard PCBs.
Thermal behavior is quantified by a dissipation figure of 635 W at a 400 V DC bus. This heat load is removed by an internal fan that idles at 50% of its rated speed during medium demand. Motor inductance can be as low as 0.74 mH, which helps prevent excessive ripple when the device's voltage rise rate reaches 4.0 kV/µs. The output bridge introduces only 6 V of residual drop, improving efficiency at light load. The aluminum housing measures 386 mm in height, 190 mm in width, and 244 mm in depth, excluding connectors, and weighs 13 kg. Two nine-pin Sub-D Profibus ports provide fieldbus routing without additional gateways.