The SERVOSTAR-403M-C is a reliable servo amplifier designed for applications requiring high control and safety, particularly in harsh industrial environments. It operates on a 120/230V AC supply with a current consumption of 0.9/0.6 A, accommodating both 50Hz and 60Hz frequencies to ensure versatility.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

In applications where higher degree of control and safety are required, the SERVOSTAR-403M-C is an efficient and reliable servo amplifier designed for harsh industrial environments. This device operates on a 120/230V AC supply voltage with a current consumption of 0.9/0.6A depending on voltage input. It is the voltage that is the most critical factor. There are not many power sources available, which means the amplifier has to support both 50Hz and 60Hz frequency in order not to restrict the marketplace. The primary fusing is rated at 3.15 amperes, it is designed to supply 24V output with an accuracy of + or 1 % variation. Furthermore, it has a maximum output current of five amperes. In addition, the safety and reliability of the device is enhanced by virtue of its design to withstand short circuits.

Due to its normal operational capability within the temperature range of 0 to +60 degrees Celsius, SERVOSTAR 403M-C is able to be used in a wide variety of conditions one encounters in industries. It is therefore vertically fitted on the DIN rail, to ensure that there is enough ventilation, and there must be fifty millimeters of open space above and fifty millimeters below the bridge.

Compliance with ul standards (country America) and cUl (country Canada) has been met with resolving servo amplifier in the UL file number E217428. As well as it meets the underwriters laboratory 840 and 508C which are standards for electrically propels power conversion equipment in America and Canada respectively. In AGD, compliance of SERVOSTAR 403M-C to these standards is ensured by independent UL inspections as well as recurrent evaluations. These standards are meant to the extent possible that the SERVOSTAR 403M-C shall be designed to avoid a risk of causing fire, electric shock and injuries due to mechanical structural failure.

Dimensions
115 x 365 x 275 mm
Frequency
50/60 Hz
Input current at 120 V
0.9 A
Input current at 230 V
0.6 A
Input voltage
120/230 V AC
Max differential input voltage
10 V
Max output current
5 A
Mounting method
DIN-rail, vertical
Output fusing
Short-circuit proof
Output voltage
24 V ±1%
Primary fuse rating
3.15 A T
Required clearance
50 mm above and below
Residual ripple
<150 mVss
Switching peaks
<240 mVss
Temperature range
0 to +60 °C
Weight
0.75 kg

Frequently Asked Questions about SERVOSTAR-403M-C:

Q: What supply voltage and frequency does the SERVOSTAR 403M-C support?

A: The SERVOSTAR 403M-C operates on a 120/230V AC supply voltage, accommodating both 50Hz and 60Hz frequencies. This flexibility ensures that the amplifier can be used in various regions without being restricted by local power standards.

Q: What are the current consumption and fusing specifications for the SERVOSTAR 403M-C?

A: The current consumption of the SERVOSTAR 403M-C is 0.9A at 120V AC and 0.6A at 230V AC. The primary fusing is rated at 3.15 amperes, and the device supplies a 24V output with an accuracy of ~1%, with a maximum output current of five amperes.

Q: How does the SERVOSTAR 403M-C ensure safety and reliability in harsh industrial environments?

A: The SERVOSTAR 403M-C is designed to withstand short circuits, enhancing its safety and reliability. It operates within a temperature range of 0 to +60 degrees Celsius, making it suitable for a wide variety of industrial conditions. The amplifier is designed for vertical mounting on a DIN rail, ensuring adequate ventilation with 50 millimeters of open space above and below the unit.

Q: What UL and cUL standards does the SERVOSTAR 403M-C comply with, and why are these important?

A: The SERVOSTAR 403M-C complies with UL standards in the United States and cUL standards in Canada, specifically UL 840 and 508C for electrically powered conversion equipment. These certifications, referenced under UL file number E217428, are crucial as they ensure the device is designed to minimize the risks of fire, electric shock, and injuries due to mechanical failure. Compliance is verified through independent UL inspections and recurrent evaluations.

Q: How does the SERVOSTAR 403M-C maintain operational efficiency in different environments?

A: The SERVOSTAR 403M-C is engineered to operate efficiently across a wide temperature range (0 to +60 degrees Celsius) and is designed for vertical installation on a DIN rail. The specified spacing of 50 millimeters above and below the unit ensures proper ventilation, maintaining operational efficiency even in harsh industrial environments.


Internal Product Review

  • ‘‘Compliance is verified through independent UL inspections and recurrent evaluations, minimizing risks of fire, electric shock, and mechanical failure, thereby ensuring a high level of operational safety. The SERVOSTAR 403M-C can operate in a temperature range of 0 to +60 degrees Celsius, making it appropriate for a variety of industrial settings.’’