The Kollmorgen M.1016.9694 R8, part of the PIC900 Drives series, features an IEEE 802.3 Ethernet standard with a 10 Mbps data rate. This drive includes two RS232 ports, one designated for firmware/configuration loading. It has a shock rating of 15g (11ms) and measures 41mm in width, 305mm in height, and 213mm in depth.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Kollmorgen M.1016.9694 R8 is a programmable controller that is developed for industrial automation applications. The product follows the CE directives 89/336/EEC, 73/23/EEC, 92/31/EEC, and 93/68/EEC. It follows the EMC standards EN 50081-2:1993 for industrial emissions and EN 50082-2:1995 for industrial immunity.
The M.1016.9694 R8 programmable controller operates within the EMC conformance limits of EN55011 / CISPR 11 Class A. Electrostatic discharge protection is defined as 4kV contact and 8kV air in accordance with EN61000-4-2. The controller is resistant to RF electromagnetic fields in accordance with EN61100-4-3, ENV50141, and ENV50204. Electrical rapid transients are safeguarded on incoming power lines by IEC 1000-4-4. Including the latch, the physical dimensions are 1.6 inches in breadth, 12 inches in height, and 8.4 inches in depth. The vibration withstand is 10–57 Hz at 0.15 mm and 57–2000 Hz at 2g, as specified in IEC 68-2-6. The shock withstand is 4 shocks per axis at 15g for 11 ms, as specified in IEC 68-2-27. An AUI 15-pin D port with a maximum length of 50 m, a 10Base-T RJ-45 port supporting a 100 m cable length, and a 10Base-2 BNC port with an 185 m coaxial cable length are all included in the connectivity.
The M.1016.9694 R8 programmable controller can be stored at -40°C to 85°C and work in temperatures ranging from 7°C to 55°C with its surroundings. This controller can handle humidity levels between 5% and 95%, which means it does not condense. RS232 Port 1 is designated for modem use, while RS232 Port 2 is used for firmware and configuration. +5V at 1250 mA, +15V at 30 mA, and -15V at 30 mA are the power requirements. The product is certified under both UL and C/UL code E126417 for NRAQ Programmable Controllers.
Frequently Asked Questions about M.1016.9694 R8:
Q: Why does M.1016.9694 R8 support EN 61131-2 compliance?
A: It ensures the low-voltage directive requirements for programmable controllers. Compliance provides electrical safety standards and guarantees integration in programmable control systems that require consistent performance across defined voltage ranges.
Q: How does M.1016.9694 R8 handle electrical fast transients?
A: The product meets IEC 1000-4-4 that protects incoming power lines. It resists disturbances caused by switching transients that maintain stable operation and prevent functional interruptions during electrical spikes.
Q: Why does M.1016.9694 R8 feature dual RS232 ports?
A: One port is reserved for modem use and the other for firmware and configuration. Separation ensures reliable communication channels and prevents conflict in data transmission tasks.
Q: Does M.1016.9694 R8 meet shock resistance requirements?
A: Yes, it withstands 4 shocks per axis at 15g for 11 ms. The feature allows sustained durability during mechanical stress and prevents sudden hardware failures.
Q: How does M.1016.9694 R8 manage humidity tolerance?
A: It tolerates 5% to 95% non-condensing humidity. The specification allows the product to function without moisture accumulation that prevents corrosion and maintains electronic integrity under varied conditions.