AKD-P01207-NBAN-0000

  • Rated 4.5 (20 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
  • Stock: Available
  • Call for Expedited Shipping and Product Condition Options

✓ In-Stock!

Wake Industrial LLC is not an authorized distributor of this product.

AKD-P01207-NBAN-0000

  • Rated 4.5 (20 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
  • Stock: Available
  • Call for Expedited Shipping and Product Condition Options

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

The AKD-P01207-NBAN-0000 position indexer servo drive provided by Kollmorgen must portray low-resistance earthing for personnel protection. This product should be placed only on a conductive surface. The device must be kept away from plastic films, artificial fabrics and other highly insulation materials to prevent its damage. This unit must incorporate a doubled protective earth connection because of the high leakage current. Its electrical installation should be done only after making sure that the mains supply is switched off and secured against restart and in compliance with the safety work regulations. The drive associated built-in protective measures such as shielding or insulation should not be removed when it is in operating mode. This product may cause unfavorable consequences due to electrical arcing if its electrical connections are undone in the live state. The device user must remove its connections or touch its live sections only after waiting for around seven minutes to disconnect the mains power. The unit should always have a DC bus link voltage of lower than 50 V when its components are handled. The drive can be opened only by the manufacturer at any point in time. Its STO related safety assessments are to be done by the user as per EN 62061 or EN 13849 specifications. The product wiring should be done only with copper conductors featuring cross-sections according to IEC 60204 standards. This device cannot be supplied with power from a one-phase industrial supply network. The unit is not evaluated by the manufacturer for group installations. It is not to be used if the machinery or plant in which it has been installed does not fulfill the requirements of the regional directive.
Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo