AKD-B01207-NBSQ-0000
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
-
In-Stock, Ships in 3 Days
The AKD-B01207-NBSQ-0000 Kollmorgen Base version Ethernet servo drive features a SynqNet connectivity option. This drive has no scope for extension. It is meant for use with three-phase industrial power supply networks.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The AKD-B01207-NBSQ-0000 Kollmorgen servo drive has two RJ-45 connectors with inbuilt LEDs to connect to a SynqNet network. This product tends to have high electric voltage that can cause personnel injury due to electric shock at the time of its operation. The device must be fitted with a warning sign about the possibility of an automatic restart when its DRV.ENDEFAULT parameter is set to 1. This unit and its heatsink must be allowed to cool down after operation before they are handled. The drive has no need for a re-forming of the capacitors in its DC bus link circuit if the storage period is less than a year. The product might have unexpected movements if it is associated with unchecked data. This device must be adapted to the requirements of the machine in which the installation is done. The unit has plug-and-play compatibility with most standard feedback devices. Its X11 service interface is connected to the Ethernet interface of a PC using an interface cable. This servo drive should undergo an initial drive test after its wiring has been done. The product displays a few symbols like – and [] along with some others and the drive IP address and drive status on the LED display when the logic power is supplied. This device is assigned a name for identification using the WorkBench software. The unit is enabled using the Setup Wizard of the software after its connection to the drive has been established. Its fault relay contacts are in the open state when a fault is encountered. This drive depicts the fault codes on the display in the order of priority. The product related troubleshooting must be done only by qualified and trained staff in compliance with work safety rules.
Frequently Asked Questions about AKD-B01207-NBSQ-0000:
Q: Does the AKD servo drive have an Enable input?
A: Yes, the AKD servo drive has one digital input that functions like an Enable input.
Q: When does the AKD servo drive activate the brake chopper?
A: The AKD servo drive activates the brake chopper when the returned energy builds up the bus capacitor voltage.
Q: How should the wiring of the AKD servo drive inside the closed control cabinet be done?
A: The wiring of the AKD servo drive inside the closed control cabinet should be done as per IEC 60204-1 or ISO 13849-2 standards.
Q: What operating system is required to install the WorkBench software of the AKD servo drive?
A: The WorkBench software of the AKD servo drive can be installed on computers with Windows 7/8/2000/XP/Vista operating system.
Q: How many connectors of the AKD servo drive are used for connection to a SynqNet network?
A: Two connectors of the AKD servo drive are used for connection to a SynqNet network.