AKT-AT-410-000

No Tariffs On US Orders
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
    In-Stock, Ships in 3 Days

Preparing your secure checkout page...

The AKT-AT-410-000 is manufactured by Kollmorgen as part of their Advanced Kollmorgen Terminal series. It contains a Signal Voltage of 10 VDC and a Current Consumption Standard-bus of 20 mA. The AKT-AT-410-000 also has No address setting - configuration via Bus Coupler or controller and an Electrical Isolation of 500 V rms.

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The AKT-AT-410-000 is a four-channel analog input module manufactured by Kollmorgen Automation. The AKT-AT-410-000 generates signals within the voltage range of 0 to 10 Volts. The voltage is supplied to the AKT-AT-410-000 process level with a resolution of about 12 bits while the voltage is electrically isolated during transmission. The AKT-AT-410-000 bus terminal features four outputs with double wire versions, featuring common ground potential. The AKT-AT-410-000 comes with LEDs that indicate the data exchange with the bus coupler, ensuring easy monitoring of the operation status. The unit comes with IP 20 protection class while the installation position is variable. The current consumption from the standard bus is typically 100 mA

The AKT-AT-410-000 features a conversion timing of 2 milliseconds while the electrical isolation is 500 Volts. The power supply for the electronics is through a Standard-Bus, while the current consumption from the standard-Bus is typically 100 mA. To ensure proper functioning of the unit, the manufacturer recommends that it is stored and operated within the ambient conditions. The ambient operation temperature is 0 degrees Celsius to 55 degrees Celsius while the permissible ambient temperature during storage is rated at -25 degrees Celsius to 85 degrees Celsius. The permissible relative humidity is 95% none condensing. The I/O terminal is single-ended and features a common ground potential.

Before starting the components installation, ensure that the bus terminal system has been brought into a safe, powered down state. The manufacturer recommends the use of KAS Integrated Development Environment over manual configuration. Use the power contact labeled as PE as the Protective Earth. For electromagnetic compatibility, the PE contacts are coupled to the mounting rail. Therefore, for insulation testing, it is recommended that the PE supply line is disconnected at the bus coupler. Further, the PE power contact must not be used for the other potentials.

Address Setting
None
Configuration Method
Via Bus Coupler or Controller
Current Consumption (Standard Bus)
20 mA
Electrical Isolation
500 V rms
Signal Voltage
10 VDC
  • AKTAT410000
  • AKT AT 410 000
  • AKTAT-410-000