AKT-ECT-000-000 Kollmorgen
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
4 Minutes
55 Seconds
The Kollmorgen AKT-ECT-000-000 is an EtherCAT Bus Coupler from the AKT IO Terminals series designed for use on a 35 mm DIN rail. It supports up to 8192 digital I/O signals and 256 analog I/O signals, and operates with a 24 VDC power supply. This module has a baud rate of 100 MBaud, a maximum power contact current of 10 Amps, and IP20 protection class.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The AKT-ECT-000-000 bus coupler is manufactured by Kollmorgen within the AKT IO Terminals series. As an EtherCAT interface module, it connects remote I/O slices to the real-time network of a motion controller and supplies field power at the first position of a DIN rail I/O station used in packaging machines, conveyors, or assembly cells. It converts the internal terminal signal level to the EtherCAT protocol so that digital and analog sensors or actuators can be polled at deterministic cycle rates without external gateways.
The EtherCAT interface operates at a line speed of 100 MBaud, which is the standard bitrate for EtherCAT. The coupler uses 2 x RJ-45 ports in an in/out topology, so additional stations can be daisy-chained without switches. When the master requests ten 32-bit process words, the coupler returns the data in 0.01 ms, enabling deterministic sub-millisecond control loops. The internal logic and attached terminals draw a nominal 1750 mA standard-bus current, while a separate 500 mA branch feeds the backplane electronics. The IP20 housing restricts installation to enclosures and supports tool-free plug-in wiring. Dielectric strength is 500 Vrms to separate field and logic domains, and mounting follows the 35 mm DIN rail profile.
Power distribution is handled through a 24 VDC supply that enters the front spring terminals and passes through the power feed contacts. These contacts can carry up to 10 A, allowing larger peripheral loads such as solenoid manifolds to be energized without additional terminal blocks. The coupler supports up to 8192 I/O digital peripheral signals and 256 analog channels, so complex machine zones can remain on one EtherCAT segment. Station expansion is limited only by bus addressing, and as many as 65,535 I/O stations may be chained before the logical limit is reached. Automatic address assignment and the EtherCAT direct-mode protocol support simple network integration.
Frequently Asked Questions about AKT-ECT-000-000:
Q: How many analog peripheral signals are supported by the AKT-ECT-000-000?
A: The AKT-ECT-000-000 supports up to 256 analog peripheral input and output signals.
Q: What is the required power supply voltage for the AKT-ECT-000-000?
A: This device operates with a power supply of 24 VDC.
Q: Which communication protocol is used by the AKT-ECT-000-000?
A: The AKT-ECT-000-000 uses the EtherCAT protocol in Direct Mode for communication.
Q: What is the maximum number of I/O stations supported by the AKT-ECT-000-000?
A: Up to 65,535 I/O stations can be connected to this bus coupler.
Q: What mounting method is used for the AKT-ECT-000-000 module?
A: Mounting is performed using a 35 mm DIN rail for the AKT-ECT-000-000.