65WKS-CE310/6PB

  • Rated 4.6 (7 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
    In-Stock, Ships 3-5 Days
  • Call for Expedited Shipping and Product Condition Options
The 65WKS-CE310/6PB is a retired drive from the 60wks Analog Servo Amplifier Series retired by Kollmorgen. It features a 3 X 80- 220/50 ... 60Hz +max. 10% rated supply voltage and a 310 V rated DC-link voltage. The 65WKS-CE310/6PB can hold a ballast circuit pulse power of 5.4 kW and a 200 W ballast circuit continuous power reading.
✓ In-Stock!

Wake Industrial LLC is not an authorized distributor of this product.

65WKS-CE310/6PB

  • Rated 4.6 (7 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
    In-Stock, Ships 3-5 Days
  • Call for Expedited Shipping and Product Condition Options
The 65WKS-CE310/6PB is a retired drive from the 60wks Analog Servo Amplifier Series retired by Kollmorgen. It features a 3 X 80- 220/50 ... 60Hz +max. 10% rated supply voltage and a 310 V rated DC-link voltage. The 65WKS-CE310/6PB can hold a ballast circuit pulse power of 5.4 kW and a 200 W ballast circuit continuous power reading.
Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

The Kollmorgen 65WKS-CE310/6PB is a transistor - inverter. It is designed for three-phase 220 Volts AC operation and draws 1.6 kVA power. The nominal current is 6 Amps. The device has an environmental protection rating of IP00. This signifies that the drive is intended for indoor use. It needs to be mounted inside an industrial cabinet where it will be protected from dust and moisture and other corrosive elements that could damage it. Trained and experienced technical personnel should be given the responsibility of handling, installing, commissioning, and operating the 65WKS-CE310/6PB. All installation related activities should only be commenced once the product manual instructions related to installation and safety have been read and understood. The 65WKS-CE310/6PB contains ESD sensitivity parts. Therefore, standard ESD precautions should be implemented during all work related to the device.

The rating plate on the 65WKS-CE310/6PB should be checked prior to installation. The rated voltage and current should be compared with the transformer specifications and motor specifications. It should be ensured that the maximum permitted voltage of 240 Volts DC is not exceeded at the Ucc and GND terminals of the 65WKS-CE310/6PB, as an excessively high voltage at these terminals can destroy the ballast circuit of the device. The 65WKS-CE310/6PB should be sufficiently ventilated. An incorrectly installed ventilator or lack of a ventilator can destroy the device. The 65WKS-CE310/6PB should not be operated if it is not grounded properly. A ground fault in the motor cannot be detected in the absence of proper grounding. The electronic system on the device can also be destroyed if the intermediate circuit is not grounded. All ground connections should start at the same start point to prevent ground loops.

  • 65WKS-CE3106PB
  • 65WKSCE310/6PB

65WKS-CE310/6PB Technical Specifications

AC Fusing, maximum: 3 X 20 AM
Continuous power of the ballast circuit : 200 W
Pulse power of the ballast circuit: 5.4 kW
Rated DC-link Voltage: 310 V
Rated Supply Voltage: 3 X 80- 220/50 ... 60Hz +max. 10%