ACO5030A Kollmorgen
Wake Industrial LLC is not an authorized distributor of this product.
MPN:
The Kollmorgen ACO5030A is part of the 5000 Indexer Drivers series. This driver supports a maximum input voltage of 480 VAC and an input frequency of 50/60 Hz, with an input voltage tolerance of plus 10 percent to minus 15 percent. It operates with a maximum DC output current of 45 Amps and delivers 96 percent efficiency at nominal load.
Internal Product Review
The ACO5030A from Kollmorgen's 5000 Indexer Drivers series delivers high-performance drive control with a maximum DC output current of 45 A and impressive efficiency at 96%. This unit supports input voltages from 200 to 480 VAC and operates reliably in environments up to 50°C. The combination of high peak braking resistor power at 1000 W and broad voltage tolerance ensures dependable operation for demanding automation tasks.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The ACO5030A is an indexer-driver module produced by Kollmorgen within the 5000 Indexer Drivers series. It combines motion sequencing and power electronics so that a single unit can position servomotors or stepper motors in automated lines, pick-and-place cells, or packaging equipment. By integrating command handling with motor power stages, the driver offloads path generation from the PLC and delivers tightly timed moves directly to the axes.
The power section can deliver a continuous DC output of 45 A, giving ample headroom for mid-frame servo motors during acceleration and deceleration. Overall conversion efficiency reaches 96% at nominal load, minimizing cabinet heat and reducing supply-side current draw. The input stage accepts either 50 Hz or 60 Hz mains; this dual-frequency compatibility is indicated by the rating of 50/60 Hz. Line voltage variations are tolerated within +10%/-15%, so the driver remains stable on facilities where utility swing is common. When supplied with up to 480 VAC, the internal rectifier and bus capacitors generate the DC link that feeds the output bridge. A braking resistor rated for 100 W continuous and 1000 W peak connects to that bus to bleed surplus energy during rapid stops.
Peak braking power capability of 1000 W prevents over-voltage when large inertial loads stop abruptly, while the resistor’s 830 Ω value keeps dissipation within its thermal envelope. Systems that operate on lower mains can wire the unit to the minimum input of 200 VAC without altering control logic. Reliable service is maintained at ambient temperatures up to 50 °C and installation heights to 2000 m. A 32 AT line fuse safeguards against faults, and the 10 mm² power terminals simplify code-compliant wiring for three-phase feeders and the external brake resistor.