The 14.Z2.F04-1003 is a KEB Z2 three-phase motor choke rated for 16.5 A with 0.557 mH inductance. Low 31 mΩ resistance and 44 W power loss at 800 Hz make the unit a strong choice for efficient motor protection and cleaner drive output.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

KEB manufactures the 14.Z2.F04-1003 as part of its Z2 Three Phase Motor Chokes series. This component is a three-phase line choke installed between the line supply and a variable frequency drive to increase source impedance, filter high-frequency switching currents, and reduce voltage peaks delivered to motor windings in industrial automation systems. By smoothing the current waveform and limiting harmonic content, the choke reduces stress on semiconductor devices and improves electromagnetic compatibility within control cabinets. Its three-phase design allows it to condition all phases within a single component rather than requiring separate reactors for each conductor.

An inductance of 0.557 mH provides the reactance needed to attenuate differential-mode disturbances at the operating frequency of 800 Hz used by KEB drive outputs. The choke has a rated current of 16.5 A, allowing it to operate on the line side of small and midsize inverters without saturation. Copper losses are limited by a winding resistance of 31 mΩ, which reduces the additional voltage drop across the reactor. Cable lugs sized for a conductor cross-section of 10 mm² / 8 AWG fit directly onto the RK 6-10/35 power terminals, simplifying cabinet wiring. These terminals provide secure attachment points for the phase conductors while supporting the stated wire size.

The choke dissipates 44 W when excited at its nominal frequency and 61 W at 1,600 Hz, so adequate convection or panel ventilation must be provided. A mass of 5.5 kg provides mechanical stability while keeping the unit manageable during installation. The protective earth stud accepts an M6 ring terminal and should be tightened to 4.5 Nm to maintain a low-impedance safety path. The unit measures 160 mm in height, 168 mm in width, and 280 mm in depth, allowing it to share DIN rail shelves or base plates with matching braking resistors and fuses without exceeding typical enclosure depths. These measurements also provide the clearance information needed to position the choke without obstructing nearby wiring channels or ventilation paths.

Conductor Cross-section
10 mm² / 8 AWG
Depth
280 mm
Frequency
800 Hz
Height
160 mm
Inductance
0.557 mH
Pe Terminal Size
M6
Pe Torque
4.5 Nm
Power Loss At 1600 Hz
61 W
Power Loss At 800 Hz
44 W
Power Terminal Torque
2 Nm
Power Terminal Type
RK 6-10/35
Rated Current
16.5 A
Resistance
31 mΩ
Weight
5.5 kg
Width
168 mm

Frequently Asked Questions about 14.Z2.F04-1003:

Q: What conductor cross-section is compatible with the 14.Z2.F04-1003 motor choke?

A: The 14.Z2.F04-1003 supports conductor cross-sections of 10 mm² or 8 AWG for secure electrical connections.

Q: What is the rated current of the 14.Z2.F04-1003 from KEB?

A: This choke is rated for a current of 16.5 A, allowing it to handle significant three-phase loads.

Q: What is the inductance value for the KEB 14.Z2.F04-1003 motor choke?

A: The product provides an inductance of 0.557 mH, contributing effective filtering for motor circuits.

Q: What is the resistance of the windings in the 14.Z2.F04-1003?

A: The 14.Z2.F04-1003 exhibits a resistance of 31 milliohms for the windings.

Q: How much power loss occurs in the 14.Z2.F04-1003 motor choke at 800 Hz?

A: Power loss at 800 Hz operation is 44 W for the 14.Z2.F04-1003 model.