4.95 based on 202 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

07.S4.D30-3470 KEB

In-Stock, Ships 3-5 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The 07.S4.D30-3470 is a KEB S4 Combivert servo controller with a 200 V supply class and IP20 protection. Rated output current of 2.7 A and peak current of 8.5 A support stable servo response under transient load conditions. A 3.1 overload ratio makes this unit a strong fit for demanding motion-control applications.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 07.S4.D30-3470 servo controller is produced by KEB within the S4 Combivert Servo Controllers series. The unit converts three-phase mains power from the 200 V supply class into regulated output for synchronous or asynchronous servomotors used in packaging, material-handling, and general motion axes. By controlling current during acceleration, normal operation, and braking, it serves as the actuator interface between higher-level PLC commands and the motor windings in industrial automation systems.

Powered from a 200 V supply class, the controller draws a nominal input current of 3 A through a three-phase mains connection. Under continuous load, it delivers a rated output current of 2.7 A, which matches the motor stall current and supports sustained torque at standstill. Short load surges are handled by a peak current of 8.5 A, which the drive can sustain for 200 ms to reduce following errors during rapid indexing. The housing has an IP20 protection rating, so the controller is intended for installation inside a control cabinet that prevents unintended contact with electrical components. Motor cable length is limited to 50 m, and the PTC thermistor must have a cold resistance below 400 Ω to provide suitable thermal feedback. The controller is designed for operation within the temperature conditions associated with climatic category 3K3.

Upstream circuit protection is provided by a 10 A time-delay mains fuse, while cable cross sections of at least 1.5 mm² satisfy voltage-drop and thermal requirements. The controller maintains full performance at installation altitudes up to 2000 m, with its cooling design accounting for reduced air density. It tolerates relative humidity of up to 95% without condensation, consistent with the tropical classification of its climatic category. During dynamic motion, an overload ratio of 3.1 allows the motor current loop to exceed the nominal current for 200 ms. This short-term current capacity provides reserve torque for accelerating inertial loads or controlling vertical axes before the output returns to its continuous level.

Climatic Category
3K3
Input Current
3 A
Input Phases
3
Max Installation Altitude
2000 m
Max Mains Fuse
10 A
Max Motor Line Length
50 m
Max Ptc Cold Resistance
400 ohm
Max Relative Humidity
95%
Min Line Cross Section
1.5 mm2
Overload Ratio (i/id0)
3.1
Peak Current
8.5 A
Peak Current Time
200 ms
Rated Output Current
2.7 A
Stall Current
2.7 A
Supply Class
200 V
Type Of Protection
IP20

Frequently Asked Questions about 07.S4.D30-3470:

Q: What is the rated output current of the 07.S4.D30-3470 controller?

A: The 07.S4.D30-3470 servo controller has a rated output current of 2.7 A, supporting continuous operation under normal load.

Q: How many input phases does the 07.S4.D30-3470 servo controller require?

A: This model supports up to 3 input phases for its electrical connection.

Q: What is the maximum relative humidity tolerated by the 07.S4.D30-3470?

A: The 07.S4.D30-3470 controller is designed for environments with relative humidity up to 95%.

Q: What type of protection rating does the 07.S4.D30-3470 have?

A: The enclosure of this controller is built to IP20 protection standards, offering basic protection from solid objects.

Q: What is the peak current and peak time for the 07.S4.D30-3470 controller?

A: The peak current for the 07.S4.D30-3470 is 8.5 A for a maximum duration of 200 ms.

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo