19.R6.S3E-900A KEB

In-Stock, Ships 3-5 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The 19.R6.S3E-900A is a KEB R6 Combivert line regen drive with PNP input architecture and 4.4 kΩ digital input resistance. A 1 A control supply current and 305 V maximum line-to-ground voltage support confident integration in regenerative power applications. A 5 minute capacitor discharge time matched with a 5 minute minimum power-off time highlights well-managed service protection.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 19.R6.S3E-900A regenerative power module is produced by KEB within the R6 Combivert Line Regen Drives series. The unit connects to the DC link of an inverter system and directs excess braking energy back to the utility supply instead of dissipating it through resistors. This process reduces heat inside control cabinets and lowers net power consumption in automation lines that perform repeated stops, starts, or speed changes on conveyors, presses, or test stands.

The control electronics are powered by a 24 V rail that can supply 100 mA for external sensors or status LEDs. A separate analog output is limited to 5 mA, allowing the drive to transmit speed or load signals to a recorder without overloading the output stage. Digital command channels have an input impedance of 4.4 kΩ for PNP logic. Each digital output has a sink capacity of 25 mA for driving relays or optocouplers. Internally, the control circuit draws 1 A and operates with a fixed control angle of 22.0 degrees to synchronize regeneration with the line voltage. After a stop, the capacitors discharge within 5 minutes, and the controller attempts up to three error resets before latching a fault.

The insulation monitor trips if the line-to-ground potential exceeds 305 V, so utility wiring must follow local safety codes. Drive-to-drive synchronization is supported, but the link cannot exceed 1 m, which minimizes phase errors between units. Protective earth wiring must use at least 16 mm² copper to conduct fault current safely. The application must also observe a minimum power-off interval of 5 minutes before the module is energized again. Regeneration is blocked when regenerative power falls below the pulse-off threshold of -0.8 kW. For status signaling, a Form C relay can carry up to 2 A DC at a maximum contact voltage of 30 VDC, providing galvanically isolated feedback to the plant controller.

24 V Output Current
100 mA
Analog Output Current
5 mA
Auto Error Reset Count
3
Capacitor Discharge Time
5 min
Control Angle
22.0
Control Supply Current
1 A
Digital Input Resistance
4.4 kΩ
Digital Output Current
25 mA
Input Type
PNP
Max Line-to-ground Voltage
305 V
Max Sync Cable Length
1 m
Min Ground Conductor
16 mm²
Minimum Power-off Time
5 min
Pulse Off Level
-0.8 kW
Relay Output Current
2 ADC
Relay Output Voltage
30 VDC

Frequently Asked Questions about 19.R6.S3E-900A:

Q: What is the maximum line-to-ground voltage supported by the 19.R6.S3E-900A?

A: The 19.R6.S3E-900A has a maximum line-to-ground voltage of 305 V.

Q: What is the 24 V output current for the 19.R6.S3E-900A?

A: This model provides a 24 V output current rated at 100 mA.

Q: What is the minimum power-off time for the 19.R6.S3E-900A?

A: The minimum power-off time required for this device is 5 minutes.

Q: What is the digital input resistance of the 19.R6.S3E-900A?

A: Digital input resistance for this unit is specified at 4.4 kΩ.

Q: What is the relay output current for the 19.R6.S3E-900A?

A: The relay output current of this drive is rated at 2 ADC.