07.G6.FDA-YM00 KEB
Wake Industrial LLC is not an authorized distributor of this product.
MPN:
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
5 Minutes
23 Seconds
The KEB 07.G6.FDA-YM00 is an inverter from the G6 Combivert IO Inverters series, offering a rated motor power of 0.75 kW and a rated apparent output power of 1.8 kVA. It supports a control supply of 24 V DC at 400 mA and is designed for a rated input voltage of 400 V AC three-phase. The unit includes EtherCAT fieldbus, RS232/RS485 diagnostic interface, and an integrated EMC filter meeting EN 61800-3 C1/C2 standards.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 07.G6.FDA-YM00 is a compact inverter module from the G6 Combivert IO Inverters series produced by KEB. Designed for mounting in multi-axis cabinets, the unit functions as the power and control interface between a three-phase mains supply and an asynchronous or synchronous motor. Within industrial automation architectures it adjusts motor speed, provides diagnostic feedback, and coordinates motion profiles so that conveyors, pumps, or positioning axes receive the torque and velocity required by the higher-level controller.
This inverter draws its logic power from a dedicated control input of 24 V DC (+20/-15%) at 400 mA, isolating the processor and I/O from the main power bus. Parameter access and service data are exchanged through a RS232/RS485 port that supports transmission rates up to 100 kBaud, allowing direct laptop commissioning or PLC supervision. The power stage synchronizes to mains networks operating at 50/60 Hz ±2 %, while the three-phase supply must provide 400 V AC. Under rated conditions the drive delivers a continuous motor phase current of 2.6 A; this value defines thermal loading of the output transistors and guides cable sizing. An 8 kHz switching frequency shapes the PWM waveform to keep audible noise low and limits dv/dt stress on winding insulation.
On the communication side the fieldbus slot is factory-populated with an EtherCAT interface so cyclic setpoints and actual values integrate into real-time networks without additional gateways. The vector control algorithm can raise the motor shaft speed up to 599 Hz electrical output frequency, extending application range to high-speed spindles. Apparent power available at the terminals reaches 1.8 kVA, which corresponds to a rated mechanical output of 0.75 kW when driving a standard machine efficiency class motor. An integrated EMC filter that meets EN 61800-3 categories C1 and C2, plus two programmable relay outputs (30 V DC, 1 A each), reduce installation complexity and provide basic status signaling.