The 16.F4.C0G-4L11 frequency inverter is a versatile solution for motor speed control. The inverter offers features like a 400 V nominal mains voltage and a 22 A stall current at 8 kHz.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The frequency inverter 16.F4.C0G-4L11 is designed and manufactured by KEB Automation. It is a versatile device for controlling motor speed and optimizing energy efficiency. This inverter is used in various industrial automation applications. It offers features such as easy start up, adjustable settings and efficient power management.
The 16.F4.C0G-4L11 frequency inverter operates with a nominal mains voltage of 400 V with a voltage range of 305 V to 500 V. This unit can be connected to motors with a wide range of power ratings. The frequency inverter supports a typical braking resistor of 39 ohms and a minimum of 25 ohms for efficient braking. The device also handles a maximum braking current of 30 A to provide effective stopping capabilities for dynamic applications. Its stall current at 8 kHz is rated at 22A to ensure robust motor performance under varying loads. The inverter ensures secure electrical connections for reliable performance with a line cross section of 10 mm². The unit’s braking capabilities and motor protection features make it suitable for applications that require frequent motor stopping or reversing.
The F4 Combivert frequency inverter series unit also incorporates a convenient “Drive Mode” designed to simplify the initial start up process. The mode can be activated by entering a password of "500" into the CP.0 or ud.0 settings to enable a smooth manual start. To deactivate the mode users can press the "FUNC" and "ENTER" buttons simultaneously for approximately 3 seconds while the unit is in a “Stop” state. This process returns the frequency inverter to the previous operating mode. The frequency inverter has specific mechanical requirements such as a tightening torque for terminals of 1.2 Nm.
Frequently Asked Questions about 16.F4.C0G-4L11:
Q: What is the input voltage range for the KEB Automation 16.F4.C0G-4L11 frequency inverter?
A: The 16.F4.C0G-4L11 frequency inverter operates with a nominal mains voltage of 400 V. It has a voltage range from 305 V to 500 V for flexible integration in various industrial systems.
Q: What braking resistor values are supported by the 16.F4.C0G-4L11 inverter?
A: The 16.F4.C0G-4L11 inverter supports a typical braking resistor of 39 ohms. The minimum value for efficient braking is 25 ohms, making it ideal for dynamic stopping in industrial applications.
Q: What is the maximum braking current for the 16.F4.C0G-4L11 frequency inverter?
A: The KEB Automation 16.F4.C0G-4L11 inverter can handle a maximum braking current of 30 A. This high current capability ensures effective motor stopping and quick deceleration in dynamic applications.
Q: How does the 16.F4.C0G-4L11 handle stall current?
A: The 16.F4.C0G-4L11 has a stall current rating of 22 A at 8 kHz. This ensures stable motor performance even under fluctuating load conditions, making it ideal for demanding industrial environments.
Q: What are the mechanical requirements for installing the 16.F4.C0G-4L11 frequency inverter?
A: The 16.F4.C0G-4L11 inverter requires a tightening torque of 1.2 Nm for its terminals. Proper torque ensures secure electrical connections and reliable performance in all operating conditions