4.95 based on 202 reviews

🙶 Easy to navigate website and quick responses from support. Additionally, pretty fast shipping. Our mainte... 🙷

10.F4.S1D-5A10 KEB

In-Stock, Ships 3-5 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The 10.F4.S1D-5A10 is a KEB F4 Combivert frequency inverter with pulse-width modulation and a DC-voltage link. A 409.58 Hz maximum frequency and integrated braking transistor make this model especially appealing for precise motor control and controlled deceleration. Operating capability from -10 to 45 °C adds strong practical value for demanding industrial service.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 10.F4.S1D-5A10 frequency inverter is manufactured by KEB as part of the F4 Combivert Frequency Inverters series. This drive converts constant AC line power into a regulated three-phase output so a controller can vary motor speed and torque during automated production. By combining the power section, control logic, and protective hardware in a compact Design D housing, the unit fits in control cabinets and can operate standard induction or synchronous motors without a separate braking controller. It is suited for machine applications that need adjustable motor speed from a fixed supply source.

At the core of the drive is a DC intermediate circuit built as a DC-voltage link, and stored energy is switched to the motor terminals by pulse-width modulation. The default switching pattern runs at 4 kHz, which balances acoustic noise and switching losses during normal operation. Output frequency can be adjusted from zero up to 409.58 Hz, giving the drive a wide speed range for variable-torque or constant-torque loads. The DC link smooths incoming energy before the inverter stage produces the commanded motor waveform. A built-in braking transistor supports dynamic deceleration without a separate resistor controller. For installations above 1000 m, output current must be reduced by 1% per 100 m because lower air density reduces cooling capacity.

The inverter runs continuously between -10 °C and 45 °C ambient, while storage is permissible from -25 °C to 70 °C if moisture is controlled. The design is suitable for mounting at elevations up to 2000 m without additional cooling aids. After power is removed, a minimum wait of 5 min is required so the intermediate capacitors can discharge. When the unit is connected through residual-current devices, the circuit must tolerate a trip threshold of 300 mA to avoid nuisance shutdowns during high-frequency switching. Moisture control during storage helps protect insulation and internal components when the inverter is not in service.

Absolute Max Frequency
409.58 Hz
Altitude Derating
1% per 100 m above 1000 m
Braking Transistor
Yes
Dc Link Type
DC-voltage link
Default Carrier Frequency
4 kHz
Housing Design
D
Modulation Principle
Pulse-width modulation
Operating Temp Max
45 °C
Operating Temp Min
-10 °C
Power Cycle Delay Min
5 min
Rcd Trip Current Min
300 mA
Site Altitude Max
2000 m
Storage Temp Max
70 °C
Storage Temp Min
-25 °C

Frequently Asked Questions about 10.F4.S1D-5A10:

Q: What is the maximum output frequency the 10.F4.S1D-5A10 inverter can deliver?

A: The 10.F4.S1D-5A10 frequency inverter supports an absolute maximum frequency of 409.58 Hz.

Q: Does the 10.F4.S1D-5A10 inverter come with a braking transistor?

A: A built-in braking transistor is included in the 10.F4.S1D-5A10 model.

Q: What is the operating temperature range of the 10.F4.S1D-5A10 frequency inverter?

A: The minimum operating temperature for this unit is -10 °C, and the maximum is 45 °C.

Q: What type of modulation principle is used in the 10.F4.S1D-5A10 inverter?

A: This frequency inverter uses a pulse-width modulation principle for motor control.

Q: What is the maximum site altitude for the 10.F4.S1D-5A10, and how is performance affected at high elevations?

A: The 10.F4.S1D-5A10 is designed to function at altitudes up to 2000 meters, with a 1% derating per 100 meters above 1000 meters.

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo