4.95 based on 202 reviews

🙶 Great response and customer service. Back-order item was shipped sooner than expected as well. 🙷

10.F4.F3D-3440 KEB

In-Stock, Ships 3-5 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The 10.F4.F3D-3440 is a KEB F4 Combivert frequency inverter built for 3-phase, 400 V-class drive applications. Rated for 2.2 kW motor power with 5.8 A nominal output current, the inverter delivers precise and dependable control for compact industrial equipment. An 8 kHz rated operating frequency and 100 m shielded motor line length make this model a strong choice for stable, well-integrated drive performance.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 10.F4.F3D-3440 inverter is manufactured by KEB and belongs to the F4 Combivert Frequency Inverters series. It serves as a closed-loop AC drive that modulates voltage and frequency to match real-time motor load requirements, enabling precise speed regulation in automated production cells, material-handling lines, and HVAC installations. By synthesizing adjustable output waveforms from a constant supply, the unit supports energy-saving operation and soft motor starts that reduce mechanical stress on driven equipment. Closed-loop feedback also helps the drive maintain stable motor behavior when load demand changes during operation.

This drive accepts a three-phase input in the 400 V class supply range and draws a nominal 6.4 A while being protected upstream by a 10 A mains fuse. At the output side, it can deliver a continuous 2.2 kW of mechanical shaft power with a motor current of 5.8 A. The inverter has an apparent output rating of 4 kVA, giving headroom for power-factor variations under dynamic loads. Carrier pulses can be increased up to 16 kHz to minimize audible noise and current ripple, while the shielded motor cable may extend to 100 m without exceeding recommended EMC limits. A minimum braking resistor of 160 Ω can be connected to dissipate regenerated energy during rapid deceleration and support controlled stopping of high-inertia loads.

The gating pattern defaults to a rated switching frequency of 8 kHz, balancing semiconductor losses against harmonic quality. Under nominal load, the heat sink dissipates 130 W, and safe operation is maintained as long as its temperature stays below 79 °C. For short acceleration bursts, the power stage supplies 10.4 A, with an overcurrent trip set at 12.7 A to protect the IGBTs. Control terminals accept motor leads with a 1.5 mm² cross section, and the internal logic monitors line symmetry to avoid DC-link overvoltage during uneven supply conditions. The thermal and current limits help keep the power section within its intended operating range during repetitive starts and speed changes.

Input Phases
3-Phase
Line Cross Section
1.5 mm²
Max Heat Sink Temp
79 °C
Max Operating Frequency
16 kHz
Max Permissible Mains Fuse
10 A
Max Rated Motor Power
2.2 kW
Max Short-time Current
10.4 A
Min Braking Resistor
160 Ω
Nominal Input Current
6.4 A
Oc Tripping Current
12.7 A
Output Nominal Current
5.8 A
Output Nominal Power
4 kVA
Power Loss At Nominal Load
130 W
Rated Operating Frequency
8 kHz
Shielded Motor Line Length
100 m
Supply Voltage Class
400 V-Class

Frequently Asked Questions about 10.F4.F3D-3440:

Q: What type of input phases does the KEB 10.F4.F3D-3440 inverter require?

A: The 10.F4.F3D-3440 frequency inverter is designed for 3-phase input power connections.

Q: What is the maximum rated motor power that the 10.F4.F3D-3440 can handle?

A: This inverter supports a maximum rated motor power of 2.2 kW, suitable for moderate-duty motors.

Q: What is the rated and maximum operating frequency of the 10.F4.F3D-3440?

A: The 10.F4.F3D-3440 operates at a rated frequency of 8 kHz and supports a maximum operating frequency of 16 kHz.

Q: What is the maximum permissible mains fuse rating for the 10.F4.F3D-3440?

A: The maximum permissible mains fuse for this inverter is 10 A, providing required circuit protection.

Q: What is the maximum allowed length for a shielded motor line on the 10.F4.F3D-3440 inverter?

A: Up to 100 meters of shielded motor line can be used with the 10.F4.F3D-3440 to minimize electromagnetic interference.

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo