07.F4.CBD-4A03/1.4 KEB
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
4 Minutes
4 Seconds
The KEB 07.F4.CBD-4A03/1.4 is part of the F4 Combivert Frequency Inverters series and features a compact control type with a housing design D. It supplies a rated motor power of 0.75 kW, has a nominal input current of 2.8 A, and operates at a rated frequency of 4 kHz. This inverter supports three input phases and has a maximum heatsink temperature of 85 degrees Celsius.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 07.F4.CBD-4A03/1.4 is manufactured by KEB as part of the F4 Combivert Frequency Inverters series. As a frequency inverter, it synthesizes a variable-frequency, variable-voltage output from the fixed utility supply so that connected three-phase induction motors can run at controlled speeds in automated conveyors, fans, and small process machines. The device follows a compact control concept and is supplied in the D housing design to fit densely populated control panels.
This drive is rated for an apparent power of 1.8 kVA, which is the combined real and reactive power the inverter can exchange with the mains at full load. During continuous operation, the nominal input current is 2.8 A, and the power section delivers a rated output current of 2.6 A to the motor; the sizing of upstream protection and cable gauges depends on these steady-state values. An internal pulse-width-modulated stage operates at a carrier frequency of 4 kHz, which sets the resolution used to synthesize motor voltage and influences acoustic noise and switching losses. Those switching losses, together with control electronics consumption, result in a power loss of 45 W, and that heat must be removed by airflow across the heat sink to keep semiconductor junctions within limits.
The motor-side capability tops out at 0.75 kW of mechanical shaft power, matching fractional-horsepower machines used in light material transport and auxiliary equipment. The maximum heat sink temperature is 85 °C; if this level is exceeded, the drive will shut down protectively. For fault clearing, the recommended upstream protection is a 10 A mains fuse, selected so normal inrush does not cause nuisance trips while short circuits are disconnected quickly. The short-time current limit reaches 4.6 A, giving the inverter headroom for brief acceleration or overload events without reaching its 5.7 A electronic trip threshold. A 1.5 mm² line cross-section is sufficient for both supply and motor leads under these current ratings.
Frequently Asked Questions about 07.F4.CBD-4A03/1.4:
Q: What is the rated motor power capability of the 07.F4.CBD-4A03/1.4 frequency inverter?
A: The 07.F4.CBD-4A03/1.4 Combivert inverter offers a rated motor power of 0.75 kW.
Q: How many input phases are required for the 07.F4.CBD-4A03/1.4 Inverter?
A: This model supports a three-phase input configuration for power supply.
Q: What is the maximum mains fuse rating that the 07.F4.CBD-4A03/1.4 accepts?
A: The maximum main fuse size supported is 10 A for this inverter.
Q: What is the apparent power rating for the 07.F4.CBD-4A03/1.4 Combivert model?
A: The apparent power rating of this inverter is 1.8 kVA.
Q: What is the rated output current for the 07.F4.CBD-4A03/1.4 frequency inverter?
A: This inverter has a rated output current of 2.6 A.