The KEB 00.F4.010-6018 is part of the F4 Combivert Frequency Inverters series and uses a Profibus-DP fieldbus type. It features selectable baud rates from 1200 to 57600 baud, a default baud rate of 9600 baud, and is compatible with housing sizes D-E and G-L. The unit provides a 9-pole Sub-D socket for the operator connector and supports an address range from 0 to 239.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 00.F4.010-6018 is a communication option produced by KEB for drives in the F4 Combivert Frequency Inverters series. Mounted inside the inverter, it creates a serial interface that lets the drive exchange setpoints, status words, and fault codes with a supervisory PLC. By adding this module, a standalone frequency inverter can be integrated into distributed control lines typical of conveying, packaging, or processing equipment without separate gateway devices, enabling centralized parameter handling and coordinated motion or speed regulation.

Data transfer is handled through the Profibus-DP fieldbus, which organizes devices in a master-slave cycle for predictable scan times. Each board can be given any node number within the range of 0 to 239, so multiple inverters can be added to the same network without address conflicts. At power-up, the module starts with the default address of 1, allowing immediate identification on the bus. Transmission speed is selectable, and the board supports 1200/2400/4800/9600/19200/38400/57600 baud so cable length, noise immunity, and controller performance can be balanced. At startup, the link is factory-set to 9600 baud, which matches many standard Profibus analyzers and supports straightforward bus verification before higher rates are selected.

Service access is provided via a front-mounted 9-pole Sub-D socket, so external test or diagnostic devices can be connected without rewiring. Physically, the card mates only with inverters that use the D-E and G-L enclosure frames, ensuring correct standoff height and airflow once installed. Operational security is enhanced by an adjustable watchdog, and the timer window can be set from 0 to 10.00 s in increments of 0.01 s. This allows the fault reaction time to be matched closely to the dynamics of the connected machine.

Address Range
0 to 239
Baud Rates
1200/2400/4800/9600/19200/38400/57600 baud
Compatible Housing Sizes
D-E and G-L
Default Address
1
Default Baud Rate
9600 baud
Fieldbus Type
Profibus-DP
Operator Connector
9-pole Sub-D socket
Watchdog Range
0 to 10.00 s
Watchdog Resolution
0.01 s

Frequently Asked Questions about 00.F4.010-6018:

Q: What baud rates are supported by the 00.F4.010-6018 frequency inverter?

A: The 00.F4.010-6018 supports a baud rate range of 1200 to 57600 baud, accommodating various network speed requirements.

Q: What fieldbus type is used by the 00.F4.010-6018 frequency inverter?

A: This model utilizes Profibus-DP as its fieldbus type for communication.

Q: What type of operator connector does the 00.F4.010-6018 inverter have?

A: The operator connector for the 00.F4.010-6018 is a 9-pole Sub-D socket.

Q: Which housing sizes are compatible with the 00.F4.010-6018 inverter?

A: The 00.F4.010-6018 is compatible with housing sizes D-E and G-L, allowing flexible installation.

Q: What is the watchdog range and its resolution for the 00.F4.010-6018?

A: This inverter offers a watchdog range from 0 to 10.00 seconds with a resolution of 0.01 second.


Internal Product Review

  • ‘‘The 00.F4.010-6018 is a Profibus-DP fieldbus interface for KEB F4 Combivert frequency inverters, featuring a 9-pole Sub-D socket for straightforward integration. Broad baud rate support from 1200 to 57600 baud and a watchdog range of 0 to 10.00 s make the interface a strong choice for dependable inverter communication.’’