19.F2.230-4006 KEB
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The KEB 19.F2.230-4006 inverter is part of the F2 Combivert Drive Inverters series. It has a rated power of 42 kVA and a rated current of 60 Amps, with a maximum motor rating of 30 kW. The unit accepts three input phases and features an internal braking transistor and an IP20 protection rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 19.F2.230-4006 is an AC drive inverter produced by KEB within the F2 Combivert Drive Inverters series. This unit converts fixed-frequency three-phase mains power into a variable-frequency output so induction or synchronous motors can be speed-controlled in automated machinery, conveyors, and process equipment. By integrating modulation, protective hardware, and application-adjustable parameters, the inverter acts as a central element between plant power distribution and motor loads. It supports mid-range power applications that require dynamic braking and cabinet installation under indoor industrial conditions.
Rated apparent power reaches 42 kVA, giving the drive sufficient capacity for motors that draw a continuous line current of 60 A. When paired with a machine motor, the inverter can supply up to 30 kW of mechanical output, matching medium-sized pumps, fans, or material handlers. Pulse-width modulation is clocked at a maximum switching rate of 16 kHz; higher carrier frequencies lower acoustic noise but increase thermal stress, so this value marks the upper limit for fast and quiet control. Protection is limited to cabinet installation by an IP20 housing, and wiring rules call for a 3-phase feed, a 25 mm² power cable, and a 10 mm² copper protective ground conductor. The integrated braking transistor dissipates regenerated energy internally, removing the need for an external chopper.
Thermal and protection parameters align with site altitude limits. Above 1000 m, current derating begins, and operation is allowed up to 3000 m without forced cooling, provided ambient temperature remains controlled. At the highest switching speed, conversion losses reach 2100 W, so cabinet airflow must remove that heat. For upstream protection, an 80 A mains fuse is specified, while ground-fault devices must trip no lower than 300 mA against a line-to-ground threshold of 300 V.
Frequently Asked Questions about 19.F2.230-4006:
Q: What is the rated current of the 19.F2.230-4006 drive inverter?
A: The KEB 19.F2.230-4006 is rated for 60 A continuous output current.
Q: What is the maximum motor rating the 19.F2.230-4006 can handle?
A: This inverter supports a maximum motor rating of 30 kW for connected motors.
Q: What is the protection rating of the KEB 19.F2.230-4006 inverter?
A: The protection rating for the 19.F2.230-4006 is IP20, allowing indoor installation with minimal exposure to dust.
Q: Does the 19.F2.230-4006 inverter feature an internal braking transistor?
A: This model is equipped with an internal braking transistor, supporting dynamic braking.
Q: What is the maximum mains fuse rating recommended for the 19.F2.230-4006 inverter?
A: The recommended main fuse size for this unit is 80 A as specified by KEB.