24.E6.T60-3000 KEB
Wake Industrial LLC is not an authorized distributor of this product.
The KEB 24.E6.T60-3000 is part of the Combiline EMC Filters series and is built for use with three input phases at a nominal voltage of 3 x 480 V AC. This filter has a rated current of 200 Amps, a maximum voltage of 550 V AC for one minute per hour, and dissipates up to 100 Watts of power. It weighs 9.2 kilograms and measures 321 mm in height, 200 mm in width, and 190 mm in depth.
Internal Product Review
The 24.E6.T60-3000 is a KEB Combiline EMC filter built for 3 x 480 V AC systems with a 200 A rated current. Low 2.67 mA leakage current and 150% overload capacity for 60 seconds make this unit an excellent fit for high-demand drive installations.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 24.E6.T60-3000 electromagnetic compatibility filter is produced by KEB as part of the Combiline EMC Filters series. Designed for three-phase drives and inverters, the unit suppresses conducted radio-frequency noise on the line side, helping cabinets meet industrial EMC limits and protecting nearby sensors and communication lines. Installed between the plant supply and the power electronics, it helps support stable machine operation and cleaner power connections. That reduction in conducted interference is useful where encoders, control wiring, and other low-level signals share the same enclosure with the drive system.
For electrical performance, the filter is specified for a nominal line voltage of 3 x 480 V AC across its three input phases. This is the continuous operating voltage that can be applied without derating. During short-term transients, it withstands up to 550 V AC for one minute each hour, providing margin for utility overvoltage events. The conductors can carry a continuous load of 200 A, while a 60-second overload of 150 % supports motor starting currents. Leakage current is limited to 2.67 mA so ground-fault monitoring devices are not triggered in normal service. The device dissipates 100 W of heat at rated load, and its internal layout supports C2 installations with motor cables up to 100 m in length. Input connections are clamped to 15 Nm, ensuring secure line terminations under vibration.
Mechanical proportions aid panel layout. The enclosure has a depth of 190 mm, a width of 200 mm, and a height of 321 mm, giving it a compact form that fits beside drives of similar current class. Mass is held to 9.2 kg, which eases mounting without additional brackets. The protective earth is attached through an M10 stud and must be tightened to 35 Nm to maintain low impedance for high-frequency currents. Its rectangular body also simplifies placement against back panels or near cable ducting where clearance is limited.