22.E6.T60-3100 KEB
Wake Industrial LLC is not an authorized distributor of this product.
The KEB 22.E6.T60-3100 is a three-phase EMC filter from the Combiline EMC Filters series with a weight of 15.1 kilograms. It supports a rated current of 150 Amps at 400 V and 105 Amps at 480 V, and has an EMV limit class of C1. The filter features a maximum IEC fuse of 160 A, a leakage current of 2.02 mA, and can handle a maximum motor cable length of 500 meters.
Internal Product Review
The 22.E6.T60-3100 is a KEB Combiline EMC filter designed for 3-phase systems at 400 V. C1 EMC compliance and 30 kA short-circuit capacity make the assembly especially appealing for demanding drive installations. A 150 A rated current gives the filter strong application range and rounds out a very capable power quality component.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 22.E6.T60-3100 EMC filter is produced by KEB and belongs to the Combiline EMC Filters series. Designed for three-phase drive systems, the module sits between the inverter and the mains supply to attenuate conducted emissions and meet industrial radio-interference limits. By limiting common-mode and differential-mode noise, the filter helps machine builders demonstrate compliance with applicable European and North American EMC requirements while protecting nearby control electronics.
The filter satisfies the stringent limit class C1, meaning it restricts conducted interference to the lowest residential level even when mounted in a cabinet close to sensitive instrumentation. On a 400 V network, it can continuously carry a rated current of 150 A, providing ample capacity for medium-sized inverters. The internal capacitor arrangement is sized for a nominal system voltage of 400 V, and leakage current to ground is limited to 2.02 mA, reducing the likelihood that residual-current devices will trip during steady operation. Motor leads up to 500 m long can be connected downstream without exceeding the stated attenuation curve, which supports large conveyors or remote pump groups.
To handle transient conditions, the unit tolerates an overload of 150% for 60 s and withstands fault currents up to 30 kA when protected by the recommended fuses. Power loss is limited to 80 W, allowing installation in ventilated enclosures without active cooling. The enclosure weighs 15.1 kg, the phase terminals accept a tightening torque of up to 15 Nm, and the protective-earth bar requires a tightening torque of 35 Nm. On 480 V UL systems, the filter supports a continuous current of 105 A. The maximum fuse size is 160 A under IEC requirements or 175 A under UL requirements, and the unit supports three phase conductors.