20.E5.T60-10F1 KEB
Wake Industrial LLC is not an authorized distributor of this product.
The KEB 20.E5.T60-10F1 is an EMC filter from the Combiline EMC Filters series. It supports a rated current of 100 Amps and maximum input voltage of 3 x 480 Volts, with a rated frequency of 50 or 60 Hertz. The filter is designed for 3-phase plus PE systems and has a power dissipation of 30 Watts at a maximum ambient temperature of 45 degrees Celsius.
Internal Product Review
The 20.E5.T60-10F1 is a KEB Combiline EMC filter for 3 ph + PE systems up to 3 x 480 (+5%) V. The 100 A rating and 50/60 Hz compatibility make the filter a strong fit for demanding drive and power distribution applications. A 6 mA leakage current and 45 °C maximum ambient temperature support dependable EMC performance in industrial panels.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 20.E5.T60-10F1 electromagnetic compatibility filter is produced by KEB within the Combiline EMC Filters series. Installed between the mains supply and an inverter or servo drive, this component suppresses conducted interference that flows back into the plant distribution network and helps protect sensitive control electronics on the same bus. By providing line-to-line and line-to-ground attenuation, it supports automated machinery that must meet factory EMC limits without requiring extra shielded wiring.
Its maximum input of 3 x 480 (+5%) V allows the filter to be wired on common 460 V three-phase systems while still tolerating routine overvoltage events at startup. The device is rated for a continuous phase current of 100 A, so a single unit can serve several medium-power drives or one high-power inverter without parallel filtering. A phase configuration of 3 ph + PE means that the three power conductors and the protective earth pass through attenuation paths that help reduce differential and common-mode noise. The operating grid range of 50 / 60 ± 2 Hz supports both IEC and NEMA plant frequencies. Under nominal supply, a leakage current of only 6 mA helps limit touch current and reduces the chance of false trips in ground-fault monitors.
Thermal operation is limited to an ambient temperature of 45 °C, and above this point the filter must be derated or given additional ventilation. Internal losses reach 30 W at full load, so enclosure airflow or a heat sink is recommended to carry away steady heat and help prevent saturation of the suppression cores. Power lugs accept conductors up to 25 mm² / 50 mm², depending on the terminal, which supports low-resistance connections without special adapters. The housing layout allows placement beside drives or soft starters, which helps save panel space while supporting machine electromagnetic compliance targets.