The KEB 19.E4.T60-1001 is a radio interference filter from the Combiline EMC Filters series. This 3-phase external mount filter operates at 480 VAC with a line frequency of 50/60 Hz, and supports a rated current of 90 Amps. It is designed to handle ambient temperatures from -25 to +85 degrees Celsius and weighs 6.1 kilograms.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 19.E4.T60-1001 is an electromagnetic compatibility filter from KEB supplied under the Combiline EMC Filters series. It is placed on the mains side of inverters, soft starters, or servo drives to reduce conducted emissions that travel back toward the transformer and neighboring equipment. By shunting unwanted high-frequency components into a controlled impedance network, the device maintains signal integrity on factory networks and helps integrated machines pass legally required EMC tests in industrial automation. The design targets installations that rely on three-phase 480 V distribution, a standard voltage for pumps, conveyors, and presses throughout North American production lines.
It is categorized as a radio interference filter, meaning the internal inductors and capacitors form a low-pass network that blocks radio-frequency energy while allowing fundamental power flow. The filter accepts 480 VAC (+5%), so it can be wired directly to common 460 V industrial buses without a step-down transformer. The accepted mains frequency is 50/60 Hz, allowing the same unit to serve equipment used in regions with different utility standards. Its continuous load capability is 90 A, providing headroom for multiple drives or a single high-horsepower inverter connected through one filter. Even with this current rating, the assembly weighs only 6.1 kg, allowing panel mounting without heavy reinforcement.
Electrical terminals are arranged for three-phase conductors, so all three line paths receive symmetrical attenuation and equal leakage performance. Under UL procedures, the permissible continuous current is reduced to 57.2 A, a value that must be observed in panels intended for North American inspection. The chassis is designed for external installation outside the drive housing, which simplifies thermal management by keeping heat from the filter away from the sensitive power electronics cavity. The operating temperature range extends from -25 to +85 °C, allowing the filter to maintain its impedance characteristics in unheated warehouses and enclosures exposed to elevated machine-room temperatures.