The 18.E6.T60-1050 is an EMC filter produced by KEB as part of the Combiline EMC Filters series. It features a rated current of 59 Amps at 400 V and uses a spring-loaded terminal connection. The filter supports a maximum motor cable length of 50 meters for C1 and 100 meters for C2, with a leakage current of 2.1 mA and a weight of 5.50 kg.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 18.E6.T60-1050 is a three-phase electromagnetic compatibility filter manufactured by KEB for the Combiline EMC Filters series. Installed between a variable-frequency drive and the plant mains, it attenuates common-mode and differential-mode noise so that adjacent equipment can meet industrial emission limits. The unit is sized for drive housing class 3 and connects through spring-loaded terminals, allowing quick insertion during panel assembly. By limiting high-frequency interference, it helps automation systems comply with EMC directives without requiring changes to drive firmware or motor cable layouts.

At a nominal line voltage of 400 V, the filter carries up to 59 A continuously on each conductor of a three-phase supply. Internal cores dissipate only 40 W under the rated load, so panel ventilation requirements remain modest. Leakage to protective earth is limited to 2.1 mA, permitting use on networks with sensitive residual-current devices. The spring-loaded terminals accept 16 mm² output conductors, and the matching input circuit should be protected by an 80 A IEC gL/gG fuse. Four M6 mounting holes in the base plate secure the assembly directly to busbar supports. The mechanical outline matches drive housing size 3, aligning its depth and airflow paths with the associated inverter.

During short transients, the line voltage can rise to 550 V without jeopardizing insulation. The filter continues to deliver a continuous current of 48 A when the network operates at 480 V. During 60-second surge events, it withstands a 150% overload, giving drives additional current capacity for acceleration or regeneration bursts. Motor leads up to 50 m in category C1 or 100 m in category C2 can be connected without exceeding the attenuation range. The unit has a total mass of 5.50 kg, allowing it to be mounted on DIN shelves or directly on enclosure walls without additional framing.

Connection Type
Spring-Loaded Terminal
Drive Housing Size
3
Iec Fuse Size
80 A
Leakage Current
2.1 mA
Max C1 Motor Cable
50 m
Max C2 Motor Cable
100 m
Mounting Holes
4 x M6
Output Cross-section
16 mm²
Phase Count
3
Power Dissipation
40 W
Rated Current At 400 V
59 A
Rated Current At 480 V
48 A
Rated Overload (60 S)
150%
Rated Voltage
400 V
Short-term Max Voltage
550 V
Weight
5.50 kg

Frequently Asked Questions about 18.E6.T60-1050:

Q: What type of connection does the 18.E6.T60-1050 EMC filter use?

A: The 18.E6.T60-1050 uses a spring-loaded terminal connection for secure and efficient wiring.

Q: What is the maximum supported motor cable length for the 18.E6.T60-1050?

A: This filter supports a maximum motor cable length of 50 meters for C1 and 100 meters for C2 installations.

Q: What IEC fuse size does the 18.E6.T60-1050 filter require?

A: The IEC fuse size required for the 18.E6.T60-1050 is 80 A.

Q: What is the rated current of the 18.E6.T60-1050 at 400 V and 480 V?

A: At 400 V, the rated current for this EMC filter is 59 A, while at 480 V it is 48 A.

Q: What is the rated overload capability for the 18.E6.T60-1050 EMC filter?

A: The rated overload capacity of the 18.E6.T60-1050 is 150% for up to 60 seconds.


Internal Product Review

  • ‘‘The 18.E6.T60-1050 is a KEB Combiline EMC filter designed for 3-phase systems with a rated current of 59 A at 400 V. Spring-loaded terminal connections and support for up to 100 m C2 motor cable simplify panel integration and compliance planning. A low 2.1 mA leakage current makes the filter especially attractive for clean, stable drive installations.’’