18.E5.T60-10F2 KEB
Wake Industrial LLC is not an authorized distributor of this product.
The KEB 18.E5.T60-10F2 is an EMC filter from the Combiline EMC Filters series, designed for three-phase systems and supports input voltages of 400 to 480 V AC with a maximum voltage of 528 V AC. It handles a nominal current of 65 Amps, has a line frequency of 50/60 Hz, and weighs 5.1 kilograms. The filter also features a conductor size of 25 mm², suppression degree C1, and accommodates a motor cable length of 10 meters.
Internal Product Review
The 18.E5.T60-10F2 is a KEB Combiline EMC filter designed for 400/480 V AC systems and 3-phase power. With a 65 A nominal current and C1 suppression degree, the filter is a strong technical fit for demanding drive applications. Low 20 W power loss supports efficient operation and highlights the filter’s well-balanced performance.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 18.E5.T60-10F2 is a three-phase electromagnetic compatibility filter manufactured by KEB for the Combiline EMC Filters series. Installed between a drive and the mains, the unit limits high-frequency noise so that adjacent automation equipment can meet electromagnetic emission limits while still operating on standard factory voltages. The housing code G uses a closed metal shell that guides heat to the cabinet wall and adds shielding.
This filter accepts a nominal line of 400/480 V AC and remains tolerant to frequency swings around 50/60 Hz ±10%, allowing it to serve both European and North American supplies without retuning. It is rated for 65 A of continuous current, so drives that draw up to that level can be connected without exceeding thermal limits. During operation, the device leaks only 7 mA to protective ground, which helps keep residual-current devices from nuisance tripping. Internally, the inductive and capacitive elements generate about 20 W of heat, so cabinet airflow must remove that loss. A maximum phase-to-phase voltage of 528 V AC may be applied, giving margin for transient overvoltage events. The suppression degree is classified as C1, indicating suitability for installations that demand high attenuation in the 150 kHz to 30 MHz band. Connection lugs accommodate conductor cross-sections up to 25 mm², and the design is intended for IT or ungrounded power systems to avoid unwanted ground currents.
The filter supports motor leads up to 10 m in length, matching typical cabinet-to-machine distances while keeping stray inductance low. Overall height reaches 424 mm, while the width is 179.5 mm and the depth measures 64.5 mm, so the filter can slide into standard 200 mm deep enclosures beside contactors or breakers. With a weight of 5.1 kg, it can be mounted on DIN rails or panel bolts without extra reinforcement.