17.E5.T60-10F1 KEB
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
6 Minutes
31 Seconds
The KEB 17.E5.T60-10F1 is part of the Combiline EMC Filters series and is rated for 50 Amps with a maximum input voltage of 3 x 480 VAC (+5%). The filter features a DC resistance of 0.012 Ohm per phase and supports a wire size of AWG 6 or 10 mm². It weighs 3.2 Kilograms and operates at ambient temperatures up to 45 degrees Celsius.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 17.E5.T60-10F1 electromagnetic compatibility filter belongs to the Combiline EMC Filters series produced by KEB. The unit is installed between a three-phase mains supply and frequency inverters or servo drives to attenuate conducted noise, protect adjacent equipment, and help systems meet industrial emission limits. Its compact steel housing integrates threaded studs, allowing quick fastening to back plates and reducing the need for additional assembly hardware.
It carries a rated line current of 50 A, so it can serve converters drawing moderate power without saturation. The filter accepts up to 3 x 480 VAC (+5%) across its input terminals and presents only 0.012 Ω/phase of DC resistance, keeping voltage drop low. Typical differential leakage is limited to 11 mA, while asymmetrical leakage from any phase to protective earth reaches 45 mA, which affects residual-current device sizing. Internal copper losses equal 14 W of power dissipation at full load, and heat flows through the aluminum housing. The filter supports a three-phase plus protective earth network, accepts conductors up to AWG 6 / 10 mm², and weighs 3.2 kg. These traits affect cabinet layout and cabling practice.
Insulation integrity is verified during production with a phase-to-ground withstand of 2700 VDC and a phase-to-phase test of 800 VDC, each applied for 2 s. Passing these high-potential tests confirms clearance and creepage margins that protect against overvoltage events on the installation. The filter is specified for continuous operation in ambient temperatures up to 45 °C, and keeping the enclosure within this limit helps preserve component life and stable insertion loss. It is intended for cabinets exposed to repetitive inverter switching pulses while containing conducted emissions without compromising safety.