10.E5.T60-10F2 KEB
Wake Industrial LLC is not an authorized distributor of this product.
The KEB 10.E5.T60-10F2 is part of the Combiline EMC Filters series and has a rated current of 8 Amps. This low-leakage IT-HF filter supports 3-phase input at 400/480 V AC and handles a maximum voltage of 528 V AC. The filter measures 285 mm in height, 88 mm in width, 40 mm in depth, and weighs 1.3 kg.
Internal Product Review
The 10.E5.T60-10F2 is a KEB Combiline EMC filter built as a low-leakage IT-HF unit for 3-phase systems. Rated for 400/480 V AC operation at 8 A, this filter offers dependable EMC performance for drive and power conversion applications. Suppression Class C1 and 4.5 mA leakage current make this unit especially effective where controlled filtering performance is a priority.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 10.E5.T60-10F2 is an electromagnetic compatibility filter produced by KEB within the Combiline EMC Filters series. This low-leakage IT-HF component is placed between a three-phase power source and a variable-speed drive or servo amplifier to block conducted high-frequency noise that can disturb adjacent equipment on the plant bus. By introducing controlled impedance on each phase and the protective conductor, it limits differential and common-mode emissions so that automated machines meet industrial EMC limits without extra ferrite rings or shielded cable runs.
The filter carries a continuous load rating of 8 A, meaning it can be wired in applications where the drive draws up to that current without overheating. It accepts a supply of 400/480 V AC across its three input phases and tolerates grid fluctuations because the design supports 50/60 Hz ±10% operation. During switching events, the inverter can impose crest voltages, and the filter’s insulation system withstands up to 528 V AC line to line. Leakage current is limited to 4.5 mA, a value suitable for IT power systems that must observe touch-current limits in maintenance modes. Internally, the inductive and capacitive elements are sized for motor leads up to 10 m, and the recommended conductor cross-section for terminations is 4 mm², allowing straightforward integration inside standard control enclosures.
Electrically, the device belongs to suppression class C1, so it targets installations that require attenuation above 150 kHz while keeping ground current low. Thermal losses are limited to 7 W at full load, which simplifies cabinet cooling calculations. The unit has a width of 88 mm, a depth of 40 mm, and a height of 285 mm, so vertical rail mounting is possible next to contactors or circuit breakers. The allowed motor cable reach of 10 m helps maintain filter effectiveness without additional output chokes. The unit weighs only 1.3 kg, so it can be secured on DIN hardware without reinforcing the back panel.