FC-280P4K0T4H2BNCXXXSXXXXAX

Ask for Availability

Preparing your secure checkout page...

The FC-280P4K0T4H2BNCXXXSXXXXAX drive features control input/output options, including analog, digital, and pulse inputs, with power ratings from 0.37 kW to 22 kW. As part of the VLT Midi Drive FC 280 series by Danfoss, it offers mains voltage of 3x380–480 V and versatile peak voltage capabilities up to 1.25 kV.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Danfoss manufactured the FC-280P4K0T4H2BNCXXXSXXXXAX. This specific drive is a member of the VLT Midi Drive FC 280 family. One of this drive's primary characteristics is its wide range of power ratings, which range from 0.37 kW to 22 kW. This enables application versatility, supporting motors with different power needs. To guarantee compatibility with typical power sources, the device runs at a mains voltage of 3x380–480 V, a standard industrial voltage level. Compared to single-phase systems, this three-phase voltage supply offers the drive a more reliable and adequate power source, especially for higher power applications. The drive may handle peak voltages up to 1.25 kV. This standard is essential for preventing damage to the drive and any attached equipment by withstanding voltage transients and surges that may occur in industrial settings. The drive's capacity to manage high peak voltages influences its lifetime and dependability. The device has two cable length possibilities: 5 m and 50 m. This offers installation flexibility, enabling the drive to be positioned as optimally as possible in relation to the motor and control system.

Another crucial factor is the drive's rise time, which varies between 0.0712 μsec and 0.738 μsec. Rise time describes how long it takes for the drive's output voltage to go from a low to a high state. This parameter is essential for managing the motor's acceleration and overall dynamic response by regulating the pace at which the voltage provided to the motor changes. In general, faster rise times enable more accurate and sensitive motor control. Additionally, the du/dt value of the FC-280P4K0T4H2BNCXXXSXXXXAX ranges from 1.15 kV/μsec to 6.41 kV/μsec. This value shows how rapidly the voltage may fluctuate and the rate of change of the voltage over time. For applications needing quick switching and exact control, a drive with a higher du/dt value can manage abrupt voltage fluctuations. The width may be between 75 and 170 mm, the depth between 168 and 260 mm, and the height between 210 and 520 mm.

The drive offers many control input/output options, including analog, digital, and pulse inputs. These options enable accurate monitoring and control of the motor's functioning via flexible integration with various sensors and control systems. The availability of several input types increases the drive's versatility in various applications, meeting a range of automation requirements. The FC-280P4K0T4H2BNCXXXSXXXXAX is available in many enclosure sizes, ranging from K1 to K5. The enclosure size impacts the drive's weight and physical dimensions, which may vary significantly depending on the arrangement. The drive's weight might vary from 2.5 kg to 11.5 kg, depending on the type and configuration.

Cable length
5 m or 50 m
Control input options
Analog, digital or pulse
Depth
168–260 mm
Derating conditions
Manual or automatic based on environment
Du/dt
1.15–6.41 kV/μs
Height
210–520 mm
Mounting holes
Dimensions vary per model
Peak voltage
0.368–1.25 kV
Power rating
0.37–22 kW
Rise time
0.0712–0.738 μs
Supply voltage options
200–240 V single-phase; 380–480 V three-phase
Weight
2.5–11.5 kg
Width
75–170 mm

Frequently Asked Questions about FC-280P4K0T4H2BNCXXXSXXXXAX:

Q: What is the weight of the VLT Midi Drive FC 280?

A: The weight of the drive varies from 2.5 kg to 11.5 kg, depending on the model and configuration.

Q: What is the mains voltage for the VLT Midi Drive FC 280?

A: The VLT Midi Drive FC 280 operates with a mains voltage of 3x380–480 V, suitable for industrial applications.

Q: What control input/output options are available on the VLT Midi Drive FC 280?

A: The drive features a variety of control I/O options, including analog, digital, and pulse inputs, providing flexibility for different automation needs.

Q: What are the enclosure size options for the VLT Midi Drive FC 280?

A: The enclosure sizes for the VLT Midi Drive FC 280 range from K1 to K5, depending on the specific model and configuration.

Q: How large is the VLT Midi Drive FC 280 in terms of dimensions?

A: The height varies from 210 mm to 520 mm, width from 75 mm to 170 mm, and depth from 168 mm to 260 mm, depending on the model.


Internal Product Review

  • ‘‘The FC 280 provides a wide range of power ratings and enclosure sizes for flexibility in various applications. The inclusion of analog, digital, and pulse input options enhances control versatility. However, detailed specifications like efficiency class and mounting hole dimensions require further investigation in the product documentation.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo