FC-101P5K5T4E20H4 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss FC-101P5K5T4E20H4 is part of the VLT FC 101 HVAC Basic Drives series and features a power rating of 5.5 kW and 7.5 horsepower. This drive is rated for a three-phase, 380 to 480 VAC mains voltage and has IP20 chassis protection. It comes equipped with an RFI class A1 (C2) filter for electromagnetic compatibility.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-101P5K5T4E20H4 variable-frequency drive is manufactured by Danfoss within the VLT FC 101 HVAC Basic Drives series. It regulates the speed of three-phase induction motors used in air handlers, circulation pumps, and exhaust fans. By converting constant-frequency mains power into a variable-frequency output, the drive lets building automation systems match motor speed with real-time airflow or pressure demand, which can reduce energy use and mechanical wear in industrial HVAC installations. This operating method also helps connected equipment run more smoothly during changing load conditions instead of cycling abruptly between full speed and stop. In ventilation systems, that finer speed adjustment can improve airflow stability and reduce unnecessary stress on belts, bearings, and duct components during routine operation.
Rated output power reaches 5.5 kW, equivalent to about 7.5 HP, which provides enough capacity for mid-sized centrifugal loads. The input section accepts 380–480 VAC, allowing direct connection to common 400 V or 460 V plant supplies. A three-phase power source is required for proper operation, helping the rectifier draw current evenly across the incoming lines. During operation, the power components are housed in an IP20 / Chassis enclosure, so the unit is intended for protected installation inside a ventilated control panel rather than exposure to dust or water. Panel airflow remains important because this chassis style does not provide sealing against washdown or outdoor conditions.
For electromagnetic compatibility, the integrated filter meets RFI class A1 (C2), which helps reduce conducted emissions on the supply connection when wiring practices follow the applicable limits. The unit is identified as a VLT HVAC Drive, reflecting a control profile intended for common fan and pump duties in building services equipment. It is designed for balanced three-line supplies, which supports stable rectifier operation and avoids neutral current concerns that can appear in unsuitable supply arrangements. It is commonly installed in enclosed mechanical-room panels where fan and pump motors must be speed-controlled while maintaining basic electromagnetic compatibility performance.