FC-101P2K2T4E20H4 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-101P2K2T4E20H4 is a three phase HVAC drive with a power rating of 2.2 kW and a horse power of 3.0 HP. Part of the VLT FC 101 HVAC Basic Drives series, it features an IP20 chassis protection level, operates at 380–480 VAC, and comes with an RFI class A1 (C2) filter.
Internal Product Review
The FC-101P2K2T4E20H4 is a Danfoss VLT HVAC drive engineered for three-phase 380 - 480 VAC operation. A 3.0 HP output with a 2.2 kW power rating gives the unit a well-balanced profile for dependable fan and pump control. IP20 / Chassis protection and an RFI class A1 (C2) filter make this model a strong choice for clean, stable HVAC drive performance.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-101P2K2T4E20H4 is an AC variable frequency drive manufactured by Danfoss for the VLT FC 101 HVAC Basic Drives series. It converts fixed-frequency three-phase mains into a variable-frequency output so centrifugal pumps, supply fans, and exhaust blowers can match real-time demand in building automation systems. Its compact format and simplified parameter set suit small mechanical rooms and other building-service installations where panel space is limited. In typical service, it adjusts induction motor speed to improve energy efficiency, reduce wear on dampers or valves, and maintain steadier airflow or water circulation as demand changes through the day.
The drive delivers 3.0 HP, which suits light HVAC motor loads without unnecessary oversizing. Its input section accepts 380 – 480 VAC, allowing direct connection to common facility distribution boards. Operation on a three-phase network helps balance line currents during normal use. The continuous electrical 2.2 kW rating reflects the power stage's thermal load under normal operation. An IP20 / Chassis housing provides basic finger protection and is intended for installation inside a ventilated control panel.
Conducted emission control is provided by the built-in RFI class A1 (C2) filter, which helps limit interference on nearby building wiring without requiring an added line choke in many panel layouts. Within the VLT HVAC Drive range, the internal code 101 identifies the control platform used for variable-torque operation and HVAC-oriented PID functions. Parameter names and default settings follow familiar industry conventions, easing integration with BACnet or Modbus controls already used in building systems. This operating profile is suited to rooftop package units, air-handling stations, and small booster sets that need adjustable motor speed across changing daily loads.